Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 36 for “"Nebulisation"”.

  1. Surface acoustic waves nebulisation for pulmonary drug delivery

    … the high frequencies (>1MHz) employed during the nebulisation, which avoids denaturation of the delivered molecules by cavitation. The aim of this PhD is the development of a SAW nebulisation device, capable of delivering drug-loaded liposomes in a targeted manner to the deep lung tissues. The …

    glasgow Repository record for Surface acoustic waves nebulisation for pulmonary drug delivery (opens in a new tab) Download PDF for Surface acoustic waves nebulisation for pulmonary drug delivery (opens in a new tab)

  2. Antimicrobial and immuno-modulatory peptides as a treatment for lung disease and delivery by nebulisation

    … evaluate the suitability of peptide delivery by nebulisation.<br/><br/>In in vitro assays the peptides exhibited antimicrobial activity and/or anti-inflammatory effects with minimal cytotoxicity. We considered the impact of lung proteases on the peptides. Peptide incubation with CF sputum and …

    qu-belfast Repository record for Antimicrobial and immuno-modulatory peptides as a treatment for lung disease and delivery by nebulisation (opens in a new tab) Download PDF for Antimicrobial and immuno-modulatory peptides as a treatment for lung disease and delivery by nebulisation (opens in a new tab)

  3. Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials

    … in efficiency over conventional methods of nebulisation was achieved without any deterioration in sensitivity or precision. A microprocessor controlled version provided a suitable approach to routine analysis and a detailed study into the nebulisation characteristics showed that the …

    aston Repository record for Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials (opens in a new tab) Download PDF for Inductively Coupled Plasma Atomic Emission Spectroscopy for the Analysis of Trace Elements in Boron Materials (opens in a new tab)

  4. Processing, formulation and delivery strategies to ensure stable and efficacious siRNA medicines

    … with different volume median diameters (VMD). Nebulisation studies were further progressed with the novel application of a lipid-polymer hybrid formulation based on an ionisable amino-polyester (APE-LNPs) for nebulised siRNA delivery. Drop-on-demand piezoelectric inkjet printing (PIJP) was the …

    cork Repository record for Processing, formulation and delivery strategies to ensure stable and efficacious siRNA medicines (opens in a new tab) Embargoed until 9999-12-31

  5. Slurry Atomisation Using Mixed Gas Plasmas

    … gas addition as volatilisation aids in slurry nebulisation inductively coupled plasma atomic emission spectrometry (SN-ICP-AES) has been investigated using a combination of rigorous optimisation strategies and spectrochemical measurements. Three gases were studied, nitrogen, hexafluorethane …

    plymouth Repository record for Slurry Atomisation Using Mixed Gas Plasmas (opens in a new tab)

  6. Φαρμακοκινητική της εισπνεόμενης και ενδοφλεβίως χορηγούμενης κολιστίνης σε ασθενείς με λοίμωξη κατώτερου αναπνευστικού στη μονάδα εντατικής θεραπείας

    … and systemic pharmacokinetics following nebulisation of CMS at a dose of 3 MIU and 5 MIU, using a vibrating mesh nebuliser, for VAP caused by extensively drug-resistant Gram-negative pathogens was assessed. Blood samples and mini- bronchoalveolar lavage (mini-BAL) was performed post-dose …

    greece Repository record for Φαρμακοκινητική της εισπνεόμενης και ενδοφλεβίως χορηγούμενης κολιστίνης σε ασθενείς με λοίμωξη κατώτερου αναπνευστικού στη μονάδα εντατικής θεραπείας (opens in a new tab)

  7. Proliposome and Prosurfactosome Formulations for Pulmonary Drug Delivery

    … dipropionate (BDP) for pulmonary delivery via nebulisation. Initially liposomes and surfactosomes with or without cholesterol were prepared using thin film method and were compared for their VMD, span and drug entrapment. Their drug retention on extrusion through 5µm, 2µm, 1µm and 0.4µm …

    cent-lancashire Download PDF for Proliposome and Prosurfactosome Formulations for Pulmonary Drug Delivery (opens in a new tab)

  8. A Preconcentration Technique For The Determination Of Trace Elements

    … by flow injection as well as by continuous nebulisation. In an attempt to reduce dispersion of the flow injected sample in the carrier stream, four spray chamber designs were investigated - a Scott double pass spray chamber (SDPSC), a single pass spray chamber (SPSC), a bulbous-ended spray …

    plymouth Repository record for A Preconcentration Technique For The Determination Of Trace Elements (opens in a new tab)

  9. The potential of inhaled albumin nanoparticles as a delivery strategy to improve the therapeutic profile of PDE4 inhibitors

    … vivo studies, a RFM suspension was developed for nebulisation to guinea pigs.<br/><br/><b>Results</b>: HSA-NPs were manufactured successfully and shown to undergo degradation and drug release in a simulated lung environment. The use of LPS in vitro and in vivo resulted in robust acute lung …

    kings Repository record for The potential of inhaled albumin nanoparticles as a delivery strategy to improve the therapeutic profile of PDE4 inhibitors (opens in a new tab) Download PDF for The potential of inhaled albumin nanoparticles as a delivery strategy to improve the therapeutic profile of PDE4 inhibitors (opens in a new tab)

  10. Agricultural Analysis By Plasma Emission Spectroscopy With Slurry Atomisation

    … of samples introduced using aqueous solution nebulisation, hydride generation and slurry atomisation. For aqueous solutions, simplex optimisation with signal to background ratio as the criterion of merit, vertical viewing position was found to be most critical. A continuous-flow hydride …

    plymouth Repository record for Agricultural Analysis By Plasma Emission Spectroscopy With Slurry Atomisation (opens in a new tab)

  11. Plasma Spectrochemical Analysis Of Slurries

    … are the most important criteria in slurry nebulisation. The particle size should be below 5 µm, preferably below 3 µm for refractories. Comminution techniques were used to reduce samples to this size range; the comminution time depended upon sample hardness. Suitable dispersants were …

    plymouth Repository record for Plasma Spectrochemical Analysis Of Slurries (opens in a new tab)

  12. Current Challenges for the Development of Inhaled Medicines

    … stability and bioactivity before and after nebulisation. Polyethyleneimine (PEI) with different molecular weight and branching geometry were used to complex mRNA at various nitrogen-to-phosphate (N/P) ratios (4, 8, 16, and 24). Characterization included integrity, complexation, particle …

    kings Repository record for Current Challenges for the Development of Inhaled Medicines (opens in a new tab) Download PDF for Current Challenges for the Development of Inhaled Medicines (opens in a new tab)

  13. Laser ablation for sample introduction in inductively coupled plasma spectrometry.

    … Limits of detection were inferior to solutions nebulisation ICP.

    sheffield-hallam Download PDF for Laser ablation for sample introduction in inductively coupled plasma spectrometry. (opens in a new tab)

  14. Poly (D,L-Lactide) based microspheres for pulmonary delivery of proteins

    … respirable in dry powder inhalation, nebulisation of the rehydrated powders using an ultrasonic nebuliser resulted in improved aerosilisation performance compared to the air-jet nebuliser. When tested in vitro using a macrophage cell line, the PLA microspheres system exhibited a low …

    aston Download PDF for Poly (D,L-Lactide) based microspheres for pulmonary delivery of proteins (opens in a new tab)

  15. Investigating Novel Antimicrobial Strategies to Target Mycobacterium abscessus Infections

    … has led to the development of an in vitro nebulisation assay, as a potential new therapy option. We have also investigated the components of manuka honey to identify the active compounds against M. abscessus. This led us to the development of a modified vegan ‘honea’, which gained …

    aston Download PDF for Investigating Novel Antimicrobial Strategies to Target Mycobacterium abscessus Infections (opens in a new tab)

  16. The Autonomic Nervous System and Exercise Intolerance in Pulmonary Arterial Hypertension

    … baroreceptor unloading was achieved with nebulisation of a selective pulmonary vasodilator (iloprost). Larger reductions in mean pulmonary artery pressure were associated with reductions in muscle sympathetic nerve activity (MSNA) total activity, providing evidence for pulmonary arterial …

    auckland-ms Repository record for The Autonomic Nervous System and Exercise Intolerance in Pulmonary Arterial Hypertension (opens in a new tab)

  17. Cost-effectiveness of nebulised ipratropium as adjunctive therapy in acute asthma

    … intravenous aminophylline, 4-hourly fenoterol nebulisation, intravenous methylprednisolone 125mg 12-hourly, and, every four hours, either nebulised saline placebo or ipratropium bromide 500mcg in 3ml saline. Data on age, gender, initial and maximum PEFR, time to maximum PEFR, and duration of …

    cape-town Repository record for Cost-effectiveness of nebulised ipratropium as adjunctive therapy in acute asthma (opens in a new tab)

  18. Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis

    … and nebuliser derived pressure pulses. Discrete nebulisation has been investigated for the analysis of small fragments of a variety of metal alloys which could be encountered in casework investigations. External contamination together with alloy inhomogeneity have been shown to present some …

    plymouth Repository record for Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis (opens in a new tab)

  19. Directly-coupled Chromatography - Analytical Atomic Spectroscopy For Trace Metal Speciation

    … a simple HPLC-FAAS coupling utilising pulse nebulisation and a modified atom cell was developed which produced continuous chromatograms in real time. Application of this system to determining tributyltin (TBT+) compounds in seawater yielded a detection limit of 200 ng ml ˉ¹. A directly …

    plymouth Repository record for Directly-coupled Chromatography - Analytical Atomic Spectroscopy For Trace Metal Speciation (opens in a new tab)

  20. The Development and Application of ICP-MS for the Determination of Plutonium and Neptunium in the Marine Environment

    … introduction techniques. In this study, liquid nebulisation and electrothermal vaporisation were investigated. Liquid nebulisation was found to be the most reliable technique with a typical detection limit for the actinides of 5 pg ml-1 using a minimum sample volume of 3 ml. Inconsistent results …

    glasgow Download PDF for The Development and Application of ICP-MS for the Determination of Plutonium and Neptunium in the Marine Environment (opens in a new tab)

Page 1 of 2