Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Negative sequence current"”.

  1. Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors.

    … health and to predict any incipient failures. Negative sequence current monitoring is one of the well-known condition monitoring applications that capable of identifying stator faults in induction motor as well as producing fast and reliable results using a simple measurement technique. …

    adelaide Repository record for Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors. (opens in a new tab)

  2. A method of measuring negative-phase-sequence currents in a three-phase system

    A method of measuring the negative-sequence current in an unbalanced three-phase circuit. A four-winding current transformer, in conjunction with a phase shift network and an alternating current ammeter, was used for obtaining a current proportional to, and in phase with, the negative-sequence …

    vt Repository record for A method of measuring negative-phase-sequence currents in a three-phase system (opens in a new tab)

  3. Unbalance Compensation for AC Microgrid With Solid-State Transformer

    … a novel unbalance compensation system for negative-sequence current suppression with high level power compensation capability integrated into a constant 50 Hz microgrid system. It is implemented at the high-volage sides of 50Hz delta-wye transformers supplying power at their low-voltage …

    unsw Repository record for Unbalance Compensation for AC Microgrid With Solid-State Transformer (opens in a new tab)

  4. Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System

    … expected to come from IBRs. However, the fault current characteristics of IBRs put the operation of the relays in jeopardy as they are different than that of synchronous generators' (SGs) based on which the relays' operating principles are developed. Therefore, different countries have …

    york Repository record for Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System (opens in a new tab)

  5. Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors

    … frequency component (TFC) of three-phase stator currents are used as the fault detection signals. The extracted FPM and TFC signals from the three-phase currents are transformed into three-dimensional (3D) color images in a Red-Green-Blue (RGB) structure using a current-to-image transformation …

    sask Repository record for Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors (opens in a new tab)

  6. Transmission grid strength analysis and operation of inverter-based microgrids

    … model is developed based on the voltage and current control loops with a current limiter. The current limiting algorithm for the steady-state solver is developed and incorporated into the short-circuit study process. Moreover, voltage imbalance mitigation control of grid-forming inverters …

    texas Repository record for Transmission grid strength analysis and operation of inverter-based microgrids (opens in a new tab)

  7. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    … point of damaging the transformer beyond repair. Current differential transformer protection is a simple, reliable, and cost effect method of detecting turn-to-turn faults. This method of protection is only able to detect faults involving 10% of the windings or more. The sensitivity of current …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  8. Modeling, Control, and Operation of a Grid-Tied Solar Photovoltaic Inverter in Unbalanced Conditions

    … damage to the solar PV inverter from such overcurrent or overvoltage. Most solar PV inverters operate in a conventional grid-following (GFL) control, where unbalanced operation becomes a critical issue. This control scheme regulates only positive sequence currents. More recently, the research …

    usf Repository record for Modeling, Control, and Operation of a Grid-Tied Solar Photovoltaic Inverter in Unbalanced Conditions (opens in a new tab)

  9. Incipient fault diagnosis in squirrel-cage induction motors

    … such as frequency spectral side bands or negative sequence current/impedance components, etc. Specifically, this characteristic regarding the evaluation of the fault severity is also evaluated by making comparisons between the swing angle indices and the well-known side band component …

    marquette Repository record for Incipient fault diagnosis in squirrel-cage induction motors (opens in a new tab)

  10. Investigations of LC Filter Unbalance in an Inverter-Fed Permanent Magnet Synchronous Motor Drives

    … between the positive DC-bus voltage and the negative DC-bus voltage. Such voltage waveforms have several adverse effects on the motor. These include, higher stress on winding insulation, higher eddy current losses and acoustic noise. Thus, to overcome these problems, different types of …

    concordia Download PDF for Investigations of LC Filter Unbalance in an Inverter-Fed Permanent Magnet Synchronous Motor Drives (opens in a new tab)

  11. Determination of Single Pole Breaker Reclose Time and System Performance Using Real Time Simulation

    … over-voltages across the series capacitor, and negative sequence current. The system performance is evaluated using a set of metrics based on those operation difficulties. Methods used in the industry such as shunt reactor with the neutral reactor, surge arrester, and MOV are modelled and …

    uno Repository record for Determination of Single Pole Breaker Reclose Time and System Performance Using Real Time Simulation (opens in a new tab)

  12. Balancing Asymmetrical Load Using a Static Var Compensator

    … balance or symmetry in phase voltages and currents. The diversity of the load, such as single phase, arc furnaces and railway, enhances the amount of unbalance or negative sequence components. Alongside asymmetrical load, further increase in negative sequence components is introduced due to …

    chalmers Repository record for Balancing Asymmetrical Load Using a Static Var Compensator (opens in a new tab)

  13. A New Digital Relay for Dispersed Storage and generation (DSG) Units

    … such as directional inverse time-delay overcurrent, directional instantaneous overcurrent, islanding, loss-of- excitation, differential, overfrequency, underfrequency, overvoltage, undervoltage, negative-sequence current, check-synchronism, and directional power. Also, the new relay will …

    vt Repository record for A New Digital Relay for Dispersed Storage and generation (DSG) Units (opens in a new tab)

  14. Turn-to-turn fault detection in transformers using negative sequence currents

    … efficient protection technique which is based on negative sequence currents. Using this protection technique, it is possible to detect minor internal turn-to-turn faults in power transformers. Also, it can differentiate between internal and external faults. The discrimination is achieved by …

    sask Repository record for Turn-to-turn fault detection in transformers using negative sequence currents (opens in a new tab)

  15. Addressing the Performance of Distance Relays in Presence of Inverter Based Resources

    … This work focuses on the impact of inverters on negative sequence component-based directional elements that assist distance relays in identifying the direction of fault current, causing incorrect tripping of relays and missing out on in-zone faults. The main reasons for these misoperations are …

    clemson Repository record for Addressing the Performance of Distance Relays in Presence of Inverter Based Resources (opens in a new tab)

  16. An active protection scheme for fault isolation and post-fault recovery in microgrids

    … passive methods. This thesis proposes a novel NegativeSequence Current Injection (NSCI)-based active protection scheme for islanded microgrids, which is designed to have high performance in terms of fault detection and discrimination capability, and at the same time, remain cost-effective and …

    strathclyde Repository record for An active protection scheme for fault isolation and post-fault recovery in microgrids (opens in a new tab)

  17. Analysis, Control, and Operation of Grid-Forming and Grid-Following Inverters in Inverter-Based Resource-Dominated Electric Power Systems

    … limits are developed by considering rated current, PWM saturation, DC-link voltage, PCC voltage, and filter characteristics. Enhanced voltage regulation and controlled droop strategies are evaluated to improve voltage regulation, frequency stability, and harmonic performance under normal …

    alabama Repository record for Analysis, Control, and Operation of Grid-Forming and Grid-Following Inverters in Inverter-Based Resource-Dominated Electric Power Systems (opens in a new tab)

  18. A universal grid-forming VSC control for future power system

    … of active and reactive power output by injecting current through a vector current controller at a given phase. The grid phase is tracked by using a phase-locked loop (PLL) at all times. Different outer controller can be applied for different control purposes such as active power and voltage …

    strathclyde Repository record for A universal grid-forming VSC control for future power system (opens in a new tab)

  19. Condition monitoring of high efficiency heating, ventilation and air conditioning systems

    … concerns of a future energy crisis, and heavy negative environmental impacts. An air handler, or air handling unit, is a device used to condition and circulate air as part of a HVAC system. The operation of air handlers account, on average, for 40% of an industrial site’s total energy …

    gatech Repository record for Condition monitoring of high efficiency heating, ventilation and air conditioning systems (opens in a new tab)

Page 1 of 2