Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"Negative sequence voltage"”.

  1. A Novel Frequency Control and Flexible Dynamic Boundary Microgrids to Improve Grid Resiliency and Facilitate Renewable Generation Integration

    … Constraints for three-phase power unbalance and voltage unbalance are also considered for the first time. Secondly, a real-time power balance control strategy is studied for dynamic boundary MGs. Due to the smaller size and number of generation units, MGs are more susceptible to large internal …

    utk-theses Repository record for A Novel Frequency Control and Flexible Dynamic Boundary Microgrids to Improve Grid Resiliency and Facilitate Renewable Generation Integration (opens in a new tab)

  2. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    … a tapchanger is used to increase or decrease the voltage on one side of the transformer. Digital current differential relays, which monitor tap changer position, compensate for current imbalances due to tapchanger operation. Other causes of current imbalance include current transformer saturation, …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  3. Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System

    … IEEE 2800 Standard mandates that IBRs generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs' negative-sequence current lead the negative-sequence voltage by 90-100 degrees to emulate SGs and reduce the likelihood of …

    york Repository record for Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System (opens in a new tab)

  4. Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors

    … different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty …

    sask Repository record for Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors (opens in a new tab)

  5. Control and fault tolerance improvement of the class of modular multilevel converters

    … for various applications at medium- and high-voltage levels including adjustable speed drives, solid-state transformers, grid integration of renewable energy resources, etc. However, for each application, unique operational and control challenges are imposed. As a result, unique control …

    gatech Repository record for Control and fault tolerance improvement of the class of modular multilevel converters (opens in a new tab)

  6. Voltage Total Harmonic Distortion-Based Communication-Free Adaptive Protection Strategy for Microgrids

    … adaptive protection strategy is proposed. The voltage THD would be lesser during the grid connected mode of operation and slightly higher during the islanded mode of operation. Hence, this is considered to be primary factor to shift the settings among various operating conditions which provide …

    rit Repository record for Voltage Total Harmonic Distortion-Based Communication-Free Adaptive Protection Strategy for Microgrids (opens in a new tab)

  7. Analysis and practical assessment of converter-dominated power systems : stability constraints, dynamic performance and power quality

    … grid point of view, following an already imposed voltage signal. As current sources, DQCI converters do not provide effective voltage regulation. On the contrary, GFN/VSM converters behave as voltage sources behind an inductance from the grid point of view. Thus, they contribute to the entire grid …

    strathclyde Repository record for Analysis and practical assessment of converter-dominated power systems : stability constraints, dynamic performance and power quality (opens in a new tab)

  8. A Small-Scale Standalone Wind Energy Conversion System Featuring SCIG, CSI and a Novel Storage Integration Scheme

    … source inverter is used to control positive- and negative-sequence voltage components separately. The feasibility of the proposed WECS and performance of the control system under variable wind and balanced/unbalanced load conditions are analyzed and demonstrated through simulation. Finally, the …

    waterloo Repository record for A Small-Scale Standalone Wind Energy Conversion System Featuring SCIG, CSI and a Novel Storage Integration Scheme (opens in a new tab)