  1. Turn-to-turn fault detection in transformers using negative sequence currents

    … efficient protection technique which is based on negative sequence currents. Using this protection technique, it is possible to detect minor internal turn-to-turn faults in power transformers. Also, it can differentiate between internal and external faults. The discrimination is achieved by …

    sask Repository record for Turn-to-turn fault detection in transformers using negative sequence currents (opens in a new tab)

  2. A method of measuring negative-phase-sequence currents in a three-phase system

    A method of measuring the negative-sequence current in an unbalanced three-phase circuit. A four-winding current transformer, in conjunction with a phase shift network and an alternating current ammeter, was used for obtaining a current proportional to, and in phase with, the negative-sequence …

    vt Repository record for A method of measuring negative-phase-sequence currents in a three-phase system (opens in a new tab)

  3. Transmission grid strength analysis and operation of inverter-based microgrids

    … the motor load. However, the magnitude of the negative-sequence current an inverter can supply is limited by its relatively low rated current. Therefore, we investigate the range of negative-sequence current the inverter can supply and derive formulas to determine the minimum capacity required …

    texas Repository record for Transmission grid strength analysis and operation of inverter-based microgrids (opens in a new tab)

  4. Impact of Inverter-Based Resources on Grid Dynamics

    … simulator. It is found that inverters can act as negative-sequence sources to inject negative-sequence currents into the grid during the grid restoration period and thus can adversely impact the performance of protection schemes based on negative sequence components and potentially cause relay …

    ndsu Repository record for Impact of Inverter-Based Resources on Grid Dynamics (opens in a new tab)

  5. Power System - Fault Clearance with Limited Fault Current

    … provide predictable and substantial fault currents that are essential for the reliable operation of existing protection schemes. However, converter interfaced generators, governed by converter controllers, produce fault currents that are not only lower in magnitude but also less …

    chalmers Repository record for Power System - Fault Clearance with Limited Fault Current (opens in a new tab)

  6. Performing Steady State Fault Analysis in the Phasor Domain Using Inverter Based Resources

    … by a Thevenin model. And secondly, load currents can be neglected compared with fault currents. However, times are changing, and so must our methods of fault analysis. Over the past 30 years the price of fossil fuels, climate change awareness, and efficiency of non-conventional methods of …

    clemson Repository record for Performing Steady State Fault Analysis in the Phasor Domain Using Inverter Based Resources (opens in a new tab)

  7. Power Converters and Control for Grid Connected Microgrids under Unbalanced Operating Conditions

    … exchange between MGs and the main grid will add negative effects to the main grid. Since the MG is supposed to be grid friendly when connected to the external grid, the unbalanced currents should preferably be handled within the MG. Therefore, the power converters of MGs have to provide the zero …

    catania Repository record for Power Converters and Control for Grid Connected Microgrids under Unbalanced Operating Conditions (opens in a new tab)

  8. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    … Digital relays are capable of computing the negative sequence current on both primary and secondary sides of the transformer along with the phase difference between these two negative sequence currents. By using both phase and magnitude information, negative sequence current could be used to …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  9. Correcting Current Imbalances in Three-Phase Four-Wire Distribution Systems

    … system. Through this redistribution, negative- and zero-sequence currents are eliminated and a balanced system is seen upstream from the point of installation. The UCSC consists of three separate single-phase H-bridge inverters that all share the same dc-link capacitor. Each of these …

    arkansas Repository record for Correcting Current Imbalances in Three-Phase Four-Wire Distribution Systems (opens in a new tab)