Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Neutron counters"”.

  1. Synthesis and evaluation of a charge sensitive amplifier for neutron counters

    Cosmic-ray fluctuations are monitored by neutron monitors using several different kinds of proportional counter tubes. An important component of these monitors is the electronic subsystem that registers and counts output pulses from these counter tubes. Part of the electronic subsystem is a …

    nwu-za Repository record for Synthesis and evaluation of a charge sensitive amplifier for neutron counters (opens in a new tab)

  2. Analysis of the composition of Halo's 252CF neutron source

    … derground at SNOLAB. HALO consists of 128 3He neutron counters and 79 tonnes of lead. In the event of a supernova, neutrinos will interact with the lead, releasing neutrons which will be detected by the 3He neutron counters. Each neutron counter in HALO has a different neutron capture …

    laurentian Repository record for Analysis of the composition of Halo's 252CF neutron source (opens in a new tab)

  3. Calibration of the PICO-0.1 bubble chamber and development of coated inner vessels for dark matter search

    … of the Université de Montréal. Monoenergetic neutrons were produced from the 51V(p,n)51Cr reaction with a 1.6 MeV proton beam. Two 3He neutron counters used during calibrations for neutron flux normalization were also calibrated. This result is contributing in improving Monte Carlo simulations …

    laurentian Repository record for Calibration of the PICO-0.1 bubble chamber and development of coated inner vessels for dark matter search (opens in a new tab)

  4. Development of a dedicated hybrid K-edge densitometer for pyroprocessing safeguards measurements using Monte Carlo simulation models

    … inseparability argument and the limitations of neutron counters. Thus, the Hybrid K-Edge Densitometer is currently being investigated as an assay tool for the measurement of pyroprocessing materials in order to perform effective safeguards. This work details the development of a computational …

    gatech Repository record for Development of a dedicated hybrid K-edge densitometer for pyroprocessing safeguards measurements using Monte Carlo simulation models (opens in a new tab)

  5. Calibration and commissioning of the Helium and Lead Observatory

    … tonnes of lead instrumented with 128 3He-filled neutron counters. A burst of neutrinos from a supernova will interact with the lead and result in a burst of neutrons, detectable by the counters. This burst can be identified as a supernova signal. The previously existing HALO Monte Carlo …

    laurentian Repository record for Calibration and commissioning of the Helium and Lead Observatory (opens in a new tab)

  6. Synthesis and characterization of lanthanide fluorides for forensic neutron detection

    … eventually be used as a forensic and clandestine neutron detector material. There is a need for neutron detectors that have no sensitivity to any other type of radiation and can be used as a forensic tool to go back and look at an event. There is the further requirement that such detectors be hard …

    unm Repository record for Synthesis and characterization of lanthanide fluorides for forensic neutron detection (opens in a new tab)

  7. Development of wide bandgap solid-state neutron detectors

    In this work novel solid-state neutron detectors based on Gallium Nitride (GaN) have been produced and characterized. GaN is a radiation hard semiconductor which is commonly used in commercial optoelectronic devices. The important design consideration for producing GaN-based neutron detectors have …

    gatech Repository record for Development of wide bandgap solid-state neutron detectors (opens in a new tab)

  8. Modeling and Design of a Silicon-Based High-Pressure 3HE Replacement Neutron Detector

    3He has stood as a major isotope used for neutron detection for many years. Due to national concerns of a possible 3He shortage, significant effort has been put forth, in the form of 3He alternative research, to push the community to develop more cost effective and higher intrinsic efficiency …

    umkc Repository record for Modeling and Design of a Silicon-Based High-Pressure 3HE Replacement Neutron Detector (opens in a new tab)

  9. Optimization of a modular neutron detector array for the detection of halo neutron pairs using GEANT4

    The study of halo neutrons in light nuclei may require the detection of multiple neutrons in a neutron detector array. The detection of multiple neutrons is especially challenging due to all the "false-positives" induced by cross-talk events between detectors. In this work, we report on the …

    colo-mines Repository record for Optimization of a modular neutron detector array for the detection of halo neutron pairs using GEANT4 (opens in a new tab)

  10. Characterisation of a position sensitive thermal neutron detector

    New types of position sensitive thermal neutron detectors for use in neutron imaging are in high demand due to the rising cost of 3He used in most existing thermal neutron counters. A novel 6Li doped scintillation glass sheet (GS20) coupled to a multi-anode photomultiplier tube with a portable data …

    glasgow Repository record for Characterisation of a position sensitive thermal neutron detector (opens in a new tab) Download PDF for Characterisation of a position sensitive thermal neutron detector (opens in a new tab)

  11. Performance And First Deployment Of Novel 3D Nuclear Recoil Detectors

    … purpose of providing 3D charge measurements of neutron recoils during the Phase 1 beam commissioning of SuperKEKB. We find that the high-definition 3D images of ionization clouds provided by the TPCs enable 3D vector tracking of nuclear recoils, nuclear recoil species identification, and …

    hawaii Repository record for Performance And First Deployment Of Novel 3D Nuclear Recoil Detectors (opens in a new tab)

  12. SNM neutron detection using a time-gated synthetic aperture hybrid approach

    … Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or “channels,” contain a unique set of moderators with 4 atm He-3 proportional detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a …

    gatech Repository record for SNM neutron detection using a time-gated synthetic aperture hybrid approach (opens in a new tab)

  13. Operation and reactivity measurements of an accelerator driven subcritical TRIGA reactor

    … linear electron accelerator operating as a photoneutron source was coupled to the TRIGA (Training, Research, Isotope production, General Atomics) Mark II research reactor at the University of Texas at Austin (UT) to simulate the operation and characteristics of a full-scale accelerator driven …

    texas Repository record for Operation and reactivity measurements of an accelerator driven subcritical TRIGA reactor (opens in a new tab)

  14. Uranium Oxides for Solid-State Direct-Conversion Neutron Detection

    … uranium oxides as solid-state direct-conversion neutron detectors. By modeling uranium oxides as neutron detectors, we found that thick detectors with suitable uranium isotopes would be required to achieve absorption probabilities of a few percentages: 1.5–4% for 10 MeV neutrons for natural …

    umkc Repository record for Uranium Oxides for Solid-State Direct-Conversion Neutron Detection (opens in a new tab)

Page 1 of 2