Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Nitinol Stent"”.

  1. Long-term patency of nitinol stent placement in dysfunctional hemodialysis

    Purpose: To evaluate the long-term patency of stents placement on dysfunctional hemodialysis shunt after failed balloon angioplasty and analysis the factors affecting the patency of nitinol stent. Materials and methods: Eighty-three patients with dysfunctional dialysis shunts underwent bail-out …

    ajou Repository record for Long-term patency of nitinol stent placement in dysfunctional hemodialysis (opens in a new tab) Embargoed until 9999-12-31

  2. Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region

    Stents are small, wire-mesh struts that are placed into arteries after an angioplasty procedure. The purpose of a stent is to help keep the portion of the blood vessel that has been treated with angioplasty open after the procedure. Stents have been used to help substantially reduce the restenosis …

    hawaii Repository record for Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region (opens in a new tab)

  3. Characterization of superelastic nitinol wire for application to aortic stent graft design

    Aortic stent graft devices are required to treat patients with life-threatening vascular disease. These devices depend on superelastic Nitinol material for their ability to be delivered through a minimally invasive endovascular approach and then to self-expand for long-term implantation at the …

    strathclyde Repository record for Characterization of superelastic nitinol wire for application to aortic stent graft design (opens in a new tab)

  4. Perkutaner Pulmonalklappenersatz mit Polycarbonat-Urethan Klappen zur Behandlung von Pathologien des rechtsventrikulären Ausflusstraktes am Schafmodell

    … In dieser Abhandlung wird ein neuartiges Stentdesign aus einem selbstexpandierenden Nitinol-Stent und einer darin enthaltenen Polycarbonat-Urethan Klappenprothese vorgestellt. Methoden: Eine mittels Tauchtechnik hergestellte Polycarbonat-Urethan Klappenprothese im Nitinol-Stent wurde …

    cau-kiel Repository record for Perkutaner Pulmonalklappenersatz mit Polycarbonat-Urethan Klappen zur Behandlung von Pathologien des rechtsventrikulären Ausflusstraktes am Schafmodell (opens in a new tab)

  5. Finite element analysis of shape memory alloy Niti stent in coronary artery

    The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under …

    guelph Repository record for Finite element analysis of shape memory alloy Niti stent in coronary artery (opens in a new tab)

  6. MRI with MR Angiography in Endovascular Repair of Abdominal Aortic Aneurysms

    … MR safety; ferromagnetism and heating of a nitinol stent-graft. Image artefacts were also evaluated on MRI/CE MRA and CT. In addition, an extended MR protocol including velocity mapping was assessed. MRI in a 1.5 T system may be performed safely in patients with the nitinol stent-graft …

    lund Repository record for MRI with MR Angiography in Endovascular Repair of Abdominal Aortic Aneurysms (opens in a new tab) Download PDF for MRI with MR Angiography in Endovascular Repair of Abdominal Aortic Aneurysms (opens in a new tab)

  7. Design Validation of a Multi-Stage Gradually Deploying Stent

    Angioplasty, or the use of rapidly deploying stents, is a common treatment for reopening narrowed vasculature often caused by atherosclerotic plaque. However, in-stent restenosis (ISR) induced by intimal hyperplasia is a common challenge to angioplasty. High impact stresses from current stent …

    byu Repository record for Design Validation of a Multi-Stage Gradually Deploying Stent (opens in a new tab) Download PDF for Design Validation of a Multi-Stage Gradually Deploying Stent (opens in a new tab)

  8. Geometry induced flow disturbances

    … and transition to turbulence may occur. Vascular stents provide a novel method in treatment of atherosclerotic vessels. Although stents have dramatically decreased the re-stenosis rate of vessels compared to balloon-angioplasty, restenosis still occurs in 25-30% of coronary implanted stents. …

    vt Repository record for Geometry induced flow disturbances (opens in a new tab)

  9. In-vivo-Funktionalität transvenös implantierter, dezellularisierter, tissue engineerter Pulmonalklappen im Großtiermodell über ein Jahr

    … derived cells on a polymeric scaffold and a nitinol stent were transvenously implanted in 18 sheep. Valve functionality was assessed via MRI, CT and intracardiac echocardiography for one year. Regurgitation fraction > 30 % in MRI was set to be the premature study endpoint. Histology was …

    fu-berlin Repository record for In-vivo-Funktionalität transvenös implantierter, dezellularisierter, tissue engineerter Pulmonalklappen im Großtiermodell über ein Jahr (opens in a new tab)

  10. The Optimisation of Arteriovenous Fistula Vascular Access Outcomes for Haemodialysis

    … were developed. We implanted an interwoven nitinol stent to approximate the optimal fluid dynamic geometry to treat stenoses of the inflow juxta-anastomosis (JXAS). We found acceptable patency results with no loss of AVFs in the long term results. A dynamic banding (DYBAND) technique was …

    unsw Repository record for The Optimisation of Arteriovenous Fistula Vascular Access Outcomes for Haemodialysis (opens in a new tab)

  11. Perkutaner Pulmonalklappenersatz und Tissue Engineering: die Herstellung und Charakterisierung selbstexpandierender klappentragender Stents auf der Basis eines dezellularisierten Klappengerüstes

    … es einen Tissue engineerten, klappentragenden Stent auf der Basis eines dezellulariserten Klappengerüstes zu entwickeln, der sich für den perkutanen Einsatz am ovinen Großtiermodell eignet. Zusätzlich wird die Entwicklung, Funktionsfähigkeit und Qualität der gefertigten Stents evaluiert. Als …

    cau-kiel Repository record for Perkutaner Pulmonalklappenersatz und Tissue Engineering: die Herstellung und Charakterisierung selbstexpandierender klappentragender Stents auf der Basis eines dezellularisierten Klappengerüstes (opens in a new tab)

  12. Transventrikuläre Trikuspidal-Klappenstent-Implantation

    … selbstexpandierenden Trikuspidal-Klappenstent zu entwickeln und diesen anhand transösophageal-echokardiographischer Parameter in vivo zu evaluieren. Erstmals wurde ein Nitinolstent mit einem superabsorbierenden Polymer kombiniert. Hierzu sind sechs verschiedene …

    cau-kiel Repository record for Transventrikuläre Trikuspidal-Klappenstent-Implantation (opens in a new tab)

  13. Implantation von Nitinol-Stents in der Arteria femoralis superficialis - langfristige Effektivität und Einflussfaktoren -

    … der Implantation von selbstexpandierenden Nitinol-Stents in der Arteria femoralis superficialis zu untersuchen. Die Effektivität wurde anhand von Primärerfolg, Offenheitsraten und klinischem Erfolg überprüft. Komplikationsraten und unerwünschte Folgeereignisse definierten die Sicherheit …

    qucosa-diss

  14. Estudo das temperaturas de transformação de fases e da caracterização da superfície da liga NiTi submetida a diferentes tratamentos térmicos para aplicação em órtese metálica

    … não indicado para aplicação como órtese (stent). A amostra 3 com tratamento térmico de 850° C não apresentou temperatura de transição martensítica. A análise de AFM teve como principal função escolher a rugosidade topográfica adequada ao ancoramento celular e revelou que a chapa azul foi a …

    brazil-ufrgs Repository record for Estudo das temperaturas de transformação de fases e da caracterização da superfície da liga NiTi submetida a diferentes tratamentos térmicos para aplicação em órtese metálica (opens in a new tab)