Showing 1 to 17 of 17 for “"Nitinol Stent"”.
-
Long-term patency of nitinol stent placement in dysfunctional hemodialysis
Purpose: To evaluate the long-term patency of stents placement on dysfunctional hemodialysis shunt after failed balloon angioplasty and analysis the factors affecting the patency of nitinol stent. Materials and methods: Eighty-three patients with dysfunctional dialysis shunts underwent bail-out …
-
Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region
Stents are small, wire-mesh struts that are placed into arteries after an angioplasty procedure. The purpose of a stent is to help keep the portion of the blood vessel that has been treated with angioplasty open after the procedure. Stents have been used to help substantially reduce the restenosis …
-
Characterization of superelastic nitinol wire for application to aortic stent graft design
Aortic stent graft devices are required to treat patients with life-threatening vascular disease. These devices depend on superelastic Nitinol material for their ability to be delivered through a minimally invasive endovascular approach and then to self-expand for long-term implantation at the …
-
Perkutaner Pulmonalklappenersatz mit Polycarbonat-Urethan Klappen zur Behandlung von Pathologien des rechtsventrikulären Ausflusstraktes am Schafmodell
… In dieser Abhandlung wird ein neuartiges Stentdesign aus einem selbstexpandierenden Nitinol-Stent und einer darin enthaltenen Polycarbonat-Urethan Klappenprothese vorgestellt. Methoden: Eine mittels Tauchtechnik hergestellte Polycarbonat-Urethan Klappenprothese im Nitinol-Stent wurde …
-
Finite element analysis of shape memory alloy Niti stent in coronary artery
The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under …
-
MRI with MR Angiography in Endovascular Repair of Abdominal Aortic Aneurysms
… MR safety; ferromagnetism and heating of a nitinol stent-graft. Image artefacts were also evaluated on MRI/CE MRA and CT. In addition, an extended MR protocol including velocity mapping was assessed. MRI in a 1.5 T system may be performed safely in patients with the nitinol stent-graft …
-
Design Validation of a Multi-Stage Gradually Deploying Stent
Angioplasty, or the use of rapidly deploying stents, is a common treatment for reopening narrowed vasculature often caused by atherosclerotic plaque. However, in-stent restenosis (ISR) induced by intimal hyperplasia is a common challenge to angioplasty. High impact stresses from current stent …
-
Geometry induced flow disturbances
… and transition to turbulence may occur. Vascular stents provide a novel method in treatment of atherosclerotic vessels. Although stents have dramatically decreased the re-stenosis rate of vessels compared to balloon-angioplasty, restenosis still occurs in 25-30% of coronary implanted stents. …
-
In-vivo-Funktionalität transvenös implantierter, dezellularisierter, tissue engineerter Pulmonalklappen im Großtiermodell über ein Jahr
… derived cells on a polymeric scaffold and a nitinol stent were transvenously implanted in 18 sheep. Valve functionality was assessed via MRI, CT and intracardiac echocardiography for one year. Regurgitation fraction > 30 % in MRI was set to be the premature study endpoint. Histology was …
-
The Optimisation of Arteriovenous Fistula Vascular Access Outcomes for Haemodialysis
… were developed. We implanted an interwoven nitinol stent to approximate the optimal fluid dynamic geometry to treat stenoses of the inflow juxta-anastomosis (JXAS). We found acceptable patency results with no loss of AVFs in the long term results. A dynamic banding (DYBAND) technique was …
-
Perkutaner Pulmonalklappenersatz und Tissue Engineering: die Herstellung und Charakterisierung selbstexpandierender klappentragender Stents auf der Basis eines dezellularisierten Klappengerüstes
… es einen Tissue engineerten, klappentragenden Stent auf der Basis eines dezellulariserten Klappengerüstes zu entwickeln, der sich für den perkutanen Einsatz am ovinen Großtiermodell eignet. Zusätzlich wird die Entwicklung, Funktionsfähigkeit und Qualität der gefertigten Stents evaluiert. Als …
-
Επαναστένωση των ενδοαγγειακών προθέσεων (STENT) των περιφερικών αγγείων: συγκριτική μελέτη με έγχρωμη Doppler υπερηχοτομογραφία, πολυτομική υπολογιστική τομογραφία και ψηφιακή αφαιρετική αγγειογραφία
… protocols in the quantitativeassessment of in-stent restenosis of the peripheral arterial stents and tocompare the results with these from digital subtraction angiography and colorDoppler ultrasonography. We suggested and followed a dual researchprospective scheme of both in-vitro and in-vivo …
-
Transventrikuläre Trikuspidal-Klappenstent-Implantation
… selbstexpandierenden Trikuspidal-Klappenstent zu entwickeln und diesen anhand transösophageal-echokardiographischer Parameter in vivo zu evaluieren. Erstmals wurde ein Nitinolstent mit einem superabsorbierenden Polymer kombiniert. Hierzu sind sechs verschiedene …
-
Implantation von Nitinol-Stents in der Arteria femoralis superficialis - langfristige Effektivität und Einflussfaktoren -
… der Implantation von selbstexpandierenden Nitinol-Stents in der Arteria femoralis superficialis zu untersuchen. Die Effektivität wurde anhand von Primärerfolg, Offenheitsraten und klinischem Erfolg überprüft. Komplikationsraten und unerwünschte Folgeereignisse definierten die Sicherheit …
-
Estudo das temperaturas de transformação de fases e da caracterização da superfície da liga NiTi submetida a diferentes tratamentos térmicos para aplicação em órtese metálica
… não indicado para aplicação como órtese (stent). A amostra 3 com tratamento térmico de 850° C não apresentou temperatura de transição martensítica. A análise de AFM teve como principal função escolher a rugosidade topográfica adequada ao ancoramento celular e revelou que a chapa azul foi a …