Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"Noise pulses"”

  1. Evaluation of preview cues to enhance recall of auditory sequential information

    … speech or an abstract sound containing white noise pulses to indicate the upcoming number of abnormal patients, or no preview cue. The number of abnormal patients (within-subjects) was zero, one, two, or three. Results: Preview cue did not improve non-clinician participants’ability to identify …

    lingnan Repository record for Evaluation of preview cues to enhance recall of auditory sequential information (opens in a new tab)

  2. A study of delay lines and the development of design criteria for HF communications receiver noise blankers

    … and man-made disturbances which result in noise pulses of random amplitude and randomly spaced in time have long been experienced in the communications field. Design features of an RF blanker for this type of noise are investigated. The specifications of functional blocks are established. …

    nps Repository record for A study of delay lines and the development of design criteria for HF communications receiver noise blankers (opens in a new tab)

  3. The development and application of the phosphor-photomultiplier combination to the detection and spectrometry of low energy quanta

    … a means of greatly reducing the number of dark noise pulses. A two channel pulse height analyser was devised to enable the distribution of the total number of photoelectrons released in each scintillation to be determined. The single phototube counter was also investigated and the results …

    unsw Repository record for The development and application of the phosphor-photomultiplier combination to the detection and spectrometry of low energy quanta (opens in a new tab)

  4. The Development of a Stepped Frequency Microwave Radiometer and Its Application to Remote Sensing of the Earth

    … utilized a closed-loop feedback method, whereby noise pulses were added to the received electromagnetic radiation to achieve a null balance in a Dicke switched radiometer. Stability was achieved through the use of a constant temperature enclosure around the low loss microwave front end. The Dicke …

    odu Repository record for The Development of a Stepped Frequency Microwave Radiometer and Its Application to Remote Sensing of the Earth (opens in a new tab)

  5. Photoneutron spectra from monoenergetic photons on Pb208 in the giant resonance

    … the photomultipliers were used to reject random noise pulses', and neutrons were identified against the high gamma background by pulse-shape discrimination. The neutron energy resolution at 1.46 m was +3.5% at 6 MeV and +2.5% for en~rgies less than about 2.5 MeV. The total cross section was …

    uiuc Repository record for Photoneutron spectra from monoenergetic photons on Pb208 in the giant resonance (opens in a new tab)

  6. Signal processing techniques for airborne laser bathymetry

    … smoothing is applied to the laser waveforms for noise reduction. Results show that this process can remove noise while preserving the important characteristics of the laser signal. In order to analyze the laser reflections quantitatively, a mathematical model function that can be used to …

    uvic Repository record for Signal processing techniques for airborne laser bathymetry (opens in a new tab)