Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 2,065 for “"Non contact"”
-
Non-Contact Distillation
Leidenfrost phenomenon has been studied extensively for its role in applications ranging from nuclear reactor cooling, to metals manufacturing, combustion, and other fields. Herein, Leidenfrost phenomenon is pursued towards non-contact distillation processes with hopes of reducing or even …
-
Non-contact ultrasound
… design, development, and evaluation of two novel non-contact ultrasound imaging methods: immersion ultrasound and optical ultrasound. Immersion ultrasound utilizes traditional piezoelectric elements in a tomographic framework to develop new algorithms and acquisition methods for quantification of …
-
Non-Contact Sleep Monitoring
"The road ahead for preventive medicine seems clear. It is the delivery of high quality, personalised (as opposed to depersonalised) comprehensive medical care to all." Burney, Steiger, and Georges (1964) This world's population is ageing, and this is set to intensify over the next forty years. …
-
Non-contact surface inspection
This thesis describes the development of a non-contact inspection system, used in providing a comparative method for gauging a surface. The purpose of this system is not to measure the 3-D shape of a part. The volume difference between the part to be inspected and a master, is merely part of the …
-
Non-Contact Rock Strength Characterization
… This dissertation investigates a novel non-contact methodology to characterize intact rock strength using image-based technologies across the electromagnetic spectrum, specifically long-wave infrared and short-wave infrared. The research was conducted in two phases: (1) a field-deployed …
-
Non-contact alignment of liquid crystals
Liquid crystal displays (LCD), the main application of liquid crystals, require a uniform alignment induced by the confining substrates for their quality and function. The surface alignment of liquid crystals refers to the orientation of the liquid crystal director at the substrate surface. This …
-
Non-contact defect detection in silicon
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1984.
-
Three dimensional non-contact surface measurement
… The techniques discussed here for the purpose of non-contact surface measurement are Laser Triangulation, Light Knife and Moiré Patterns. Mathematical expressions for resolution and surface acquisition time have been derived for the methods mentioned above. In the end a numerical example is taken …
-
Non-Contact Index for Periodontal Inflammation
… can be measured with a periodontal probe. A non-contactingmethod to quantitatively measure tissue inflammation must be useful in some circumstances,particularly if data can be correlated with attachment loss. In the current study, a noncontactingspectral reflectance device (Spotmeter®) was …
-
Non-Contact Sensing for Protected Cropping
… This thesis explores innovative, non-contact sensing methodologies to address key challenges in plant water management and crop quality assessment within protected cropping. By leveraging advancements in millimeter-wave (mmWave) radar and near-infrared (NIR) spectroscopy, this work …
-
Non-Contact, Three-Dimensional Object Digitizing Systems
The new field of non-contact 3-D object digitization has many applications in industry. The state of the art in technology uses electro-optic measurement techniques such as laser based triangulation and phase measurement projection Moire profilometry, for obtaining a non-contact, X-Y-Z coordinate …
-
Non-contact force measurement using magnetic levitation
… vibrations, thermal drift, and friction at contact points or mechanical joints. These challenges are further exacerbated when physical contact between the measurement sensors and objects is required, often compromising accuracy and repeatability. While conventional force sensing techniques …
-
Non-Contact Lap Splices in Dissimilar Concretes
Non-contact lap splices placed within a single concrete placement are often used and have been studied in previous research projects. However, non-contact lap splices used with each bar in a different concrete placement such that there is a cold joint between the bars, have not been investigated. …
-
DEVELOPMENT OF NON-CONTACT MICROSPHERE CONFOCAL SCANNING MICROSCOPE
… In this thesis, a novel technique, called the non-contact microsphere confocal scanning microscope, is proposed and developed. This setup can enhance the lateral resolution to 110 nm, the axial resolution to 100nm and image contrast to 71%, while retaining the key features of the conventional …
-
Hardware development of non-contact online impedance analyzer
This dissertation presents the development of a non-contact, real-time impedance measurement system that addresses the limitations of traditional sinusoidal signal-based methods by introducing multi-harmonic signals such as square and triangular waves at a test frequency of 100 kHz. The proposed …
-
Non-Contact Evaluation Methods for Infrastructure Condition Assessment
… and tied to human judgment (the inspector). Non-contact methods can help overcoming these challenges. In this dissertation two aspects of non-contact methods are explored: inspections using unmanned aerial systems (UASs), and conditions assessment using image processing and machine learning …
-
Cyber Physical Systems for Non-contact Infrastructure Monitoring
… managers are interested in exploring new non-contact measurement methods to assess the condition of civil infrastructure. Cyber Physical Systems (CPS) such as Unmanned Aerial Vehicles (UAV) and Unmanned Ground Vehicles (UGV) have gained popularity for the inspection of civil infrastructure …
Page 1 of 104