Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 49 for “"Non-composite"”.
-
Experimental Evaluation of Non-Composite Shallow Press-Brake-Formed Steel Tub Girders
… on the girder in the fabrication shop, forming a composite modular unit once cured. The composite unit would then be shipped to the construction site to be installed. However, the option of implementing a cast-in-place deck must be explored. A critical design stage for these girders occurs during …
-
Blast Resistance of Non-Composite Tilt-Up Sandwich Panels and their Connections"
… research project investigates the behaviour of non-composite tilt-up sandwich (NCTS) panels and solid reinforced concrete (SRC) panels with realistic support conditions subjected to blast-induced shockwaves. Previous research shows that NCTS panels, identifiable by their large structural wythe, …
-
Methods to develop composite action in non-composite bridge floor systems: part I
… bridges are highly desirable. Creating composite action in currently non-composite bridge floor systems may be such a method, given that two out of every five bridges are composed of steel girders topped with concrete slabs. This thesis, combined with that of Hungerford (2004), …
-
FEA methodology for system-level redundancy evaluation: Application to non-composite steel bridges
… steel member. These mechanisms include partial composite action between the slab and steelwork and other phenomena not typically considered in current practice. The researched set of FEA procedures, techniques and inputs were benchmarked against available field experimental data and used to …
-
Fatigue behavior of post-installed shear connectors used to strengthen continuous non-composite steel bridge girders
… to change the behavior of the beam from non-composite to partially-composite. Since fatigue is one of the main concerns in designing bridges, investigating the fatigue properties of these post-installed shear connectors becomes crucial. Results from direct-shear testing show that …
-
Optimisation d'un plancher non-composite et composite d'un bâtiment en acier à l'aide d'un algorithme de la dynamique d'un peloton
… influencées par cet aspect. La dalle du non composite est l’un des types de dalles les plus courants dans les bâtiments. Ce type de dalle est constitué d’une combinaison d’acier et de béton. Des poutres en acier sont placées sous la dalle en béton et supportent un tablier métallique. Pour …
-
An analysis of global and localized creep strains and creep properties of non-composite and composite lead-free solders at room and elevated temperatures
Thesis (M.S.)--Michigan State University. Department of Materials Science and Mechanics, 1998
-
Strengthening existing steel bridge girders by the use of post-installed shear connectors
… constructed with floor systems consisting of a non-composite concrete slab over steel girders. Many of these bridges do not satisfy current load requirements and may require replacement or strengthening. A potentially economical means of strengthening these floor systems is to connect the …
-
Floor Vibrations: Girder Effective Moment of Inertia and Cost Study
… and a cost efficiency analysis comparing composite and non-composite floor systems that meet vibrations design standards, were conducted. The first study was undertaken because over-prediction of girder effective moment of inertia was the suspected cause of several recent vibration …
-
Strengthening continuous steel girder bridges with post-installed shear connectors and inelastic moment redistribution
… to the 1970s have floor systems consisting of a non-composite concrete deck over steel beams with no shear connectors. While many of these bridges are still in good condition, the structures may not satisfy current load requirements and thus may need to be strengthened or replaced to avoid …
-
The Plastic Behaviour of Composite Floor Systems in Relation to Multi-Storey Structures
… developed for floor systems, involving either non-composite design or composite design, These solutions were then used to design model beam and slab floor systems to fail by a pre-chosen mode, The agreement with experimental results confirmed the validity of the theoretical methods for both …
-
Analysis and behavior investigations of box girder bridges
… curved box-girder bridges is highly desired. The non-composite steel section must support both the fresh concrete and the entire construction loads hence steel box girders are at their critical stage during construction. In the current study, non composite straight and curved steel boxes are …
-
Fatigue Performance and Shear Demand Distributions of Clustered Shear Connectors in Composite Bridge Girders
… flow demands at the steel-concrete interface of composite bridge girders. As stud pitch increases to beyond 24 in or as studs become clustered to account for pre-cast concrete decks, this assumed shear demand distribution may be unrepresentative. Understanding shear transfer and resulting demands …
-
Improved characterization of the flexural and axial compressive resistance of welded steel box-section members
… the flexural and axial compressive resistance of non-composite welded steel box-section members, and the evaluation of the performance of these methods using data compiled from existing experimental tests and generated from parametric studies performed using finite element test simulations. An …
-
Behaviour of Concrete Sandwich Wall Panels in Flexure Using a Novel GFRP Shear Connector
… pultruded channel sections intended to enhance composite action and flexural rigidity while minimizing thermal bridging. The flanges of the channel section are embedded in either wythe. Five half-scale panels (610x280x3050 mm) were tested in four-point bending, varying the connector …
-
Feasibility Study of Partially Restrained Connections
… both hot rolled shapes and steel joists using non-composite and composite construction. The designs are than compared with respect to complexity, practicality, serviceability and economics. The results of this study show that partially restrained joist connections are economically superior to …
-
Structural capacity of steel tubular cast-in-place piling
… two methods. These two methods are based on a composite or non-composite section. Many state agencies and corporations use the non-composite equation because it is requires much less computation and is known to be conservative. However with the trends of the time, more and more structural …
-
Use of innovative anchors for composite action in rehabilitated steel structures
… as shear connection systems in steel-concrete composite beams. Alongside these welded shear stud and non-composite sections were tested for comparison. Different damage states were created using a four point load system with 20%, 40%, 60%, and 80% of the calculated ultimate loads. For each …
-
Scale and Scope Economies in the UK Life Assurance Industry
… the cost structure for various groups such as: composite and non-composite companies, bancassurance and non-bancassurance companies. We also examine the cost structure by distribution channels and size. The findings of this thesis are as follows: Firstly, we find significant overall scale …
-
Unintended composite action in beam and slab bridges
… reports from bridge tests have shown that composite action was found to develop in beam and slab bridges which were not compositely built. Based on the available literature and test reports on the subject, this paper attempts to investigate this phenomenon and the factors which could …
Page 1 of 3