Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"Non-uniformity correction"”
-
Fixed Pattern Noise Non-Uniformity Correction Through K-Means Clustering
… Fixed pattern noise presents itself through a non-uniform distribution and therefore is hard to target in noise removal. Traditional noise removal techniques assume that the noise is uniformly distributed and subsequently produces inadequate corrections. Noise correction methods that target …
-
Thermal Drift Compensation in Non-Uniformity Correction for an InGaAs PIN Photodetector 3D Flash LiDAR Camera
This thesis presents the expansion of dark non-uniformity correction (NUC) techniques to include compensation for thermal drift in a 128×128 PIN diode 3D flash LiDAR camera. 3D flash LiDAR cameras are used in a variety of applications, such as in autonomous vehicles, and for operations in various …
-
Multi-wavelength infrared imaging computer systems and applications
… imaging pyrometers (M-WIPs) that yield non-contact temperature measurements by remotely sensing the surface of objects with unknown wavelength-dependent emissivity. These M-WIP computer systems represent the state-of-art development in remote temperature measurement system based on the …
-
Heat Transfer Studies with IR Thermography Techniques
… measurements. Also, a new calibration and NUC (Non Uniformity Correction) has been made so that all the image corrections can be made automatically using MatLab code and LabView without any need of intermediate software. This will be explained more deeply in the report. Heat transfer experiments …
-
Efficient pre-segmentation filtering in MRCP
… generate cluttered and noisy, low resolution, non-isometric volume data, often with significant intensity non-uniformities. This combination of undesirable characteristics presents particular challenges for the application of automated image analysis techniques. This thesis examines the …
-
Automated morphometry for mouse brain MRI through structural parcellation and thickness estimation
… preprocessing steps such as intensity non-uniformity correction and multi-atlas based brain extraction, followed by non-rigid registration and local weighted multi-atlas label fusion. Validation of the framework demonstrated improved performance compared to single-atlas-based structural …
-
Polarimetric thermal imaging
… camera with three internal wire grid polarizers. Non uniformity correction and radiometric calibration were performed to compensate for differences in detector response and polarizer's transmittance. The scene consisted of a heated aluminum plate in front of a large area blackbody as background. …
-
Compact Lens Technologies: Curved Image Sensor and Volumetric Imaging Efficiency
… by color leveling and 2-points or 3-points non-uniformity correction (NUC). The results are compared with original figure as a proof of concept showing the capability of the device being extended to an array.
-
Segmentation of neuroanatomy in magnetic resonance images
… has been reviewed. Factors affecting image non-uniformity for a modem 1.5 Tesla imager have been investigated. These investigations demonstrate that a robust, fast, automatic three-dimensional non-uniformity correction may be applied to data as a pre-processing step. The merit of using an …
-
CONSIDERATIONS ON TWO TYPES OF SOLID-STATE DOSIMETERS FOR IONIZING RADIATION
… is primarily affected by film active layer non-uniformity and the lateral artifact. At lower doses the low signal-to-noise ratio makes film active layer non-uniformity the primary source of error for accurate dosimetry. The error from the lateral artifact gradually increases with increasing …
-
Design fabrication and characterization of high performance in GaAs/InP focal plane array in the 1-2.6 µm wavelength region
… correlated double sampling circuit, threshold non uniformity correction circuit and an output buffer stage. Integration and testing of InGaAs focal plane arrays with cut-off wavelengths of 1.7 um, 2.2 um and 2.6 um are described. The performance of the focal plane arrays was analyzed in detail …
-
Illumination Recovery For Optical Microscopy
We propose a novel solution to the correction of illumination non-uniformity without removing the imaging sample.Calibration of the spatial illumination pattern in microscopy is challenging due to the fact that the illumination source is colocated with the objective lens and therefore cannot be …
-
Modèles pour la correction d'images thermiques issues de caméras non-refroidies sans obturateur mécanique
Les caméras thermiques non refroidies mesurent le rayonnement infrarouge des objets en fonction de leur température et de leur émissivité. L'image brute obtenue est cependant dégradée par un bruit structuré spatialement non uniforme, appelé "fixed pattern noise" (FPN). La correction de ce bruit se …
-
Evaluating and Correcting 3D Flash LiDAR Imagers
This research presents methods and results of characterizing and correcting PIN photodiode 3D flash LiDAR cameras, with the goal of significantly simplifying and improving the calibration system design. 3D flash LiDAR detectors use time to digital conversion (TDC) circuits to estimate the time of …
-
Mathematical theory of the Flutter Shutter : its paradoxes and their solution
… principal en imagerie vidéo infrarouge, la non-uniformité. Il s'agit d'un bruit évolutif et structuré en colonnes causé par le capteur. La conclusion des travaux est qu'il est non seulement possible mais également efficace et robuste d'effectuer la correction sur une seule image. Cela permet …