Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"Noninvasive measurements"”

  1. The Noninvasive Measurement of Limb Blood Flow by Means of Nuclear Magnetic Resonance

    … has been developed to detect limb blood flow noninvasively. The NMR detector generates signals related to the volume and nuclear magnetization level of the flow stream. With an applied tag the same flowmeter measures velocity of flow. Both the velocity and volume flow rates of the relatively …

    marquette Repository record for The Noninvasive Measurement of Limb Blood Flow by Means of Nuclear Magnetic Resonance (opens in a new tab)

  2. Hierarchical Bayesian aspects of distributed neuromagnetic source models

    Magnetoencephalography (MEG) enables noninvasive measurements of cerebral activity with excellent temporal resolution, but localising the neural currents generating the extracranial magnetic fields admits no unique solution. By imposing some mathematical constraints on the currents, reasonable …

    aalto Repository record for Hierarchical Bayesian aspects of distributed neuromagnetic source models (opens in a new tab)

  3. Development and Use of Polarized Light Methods to Assess Structure and Composition of Biological Tissue

    … of polarized light with tissue and the noninvasive nature of optical radiation. While the depolarizing effects of multiple scattering complicate the use of polarimetry in tissue, many biological constituents affect the polarization of light such as collagen, muscle fibers, and glucose. …

    toronto-retro Repository record for Development and Use of Polarized Light Methods to Assess Structure and Composition of Biological Tissue (opens in a new tab)

  4. Design, Development, and Execution of PIV Measurements on a Randomly Packed Pebble Bed Experimental Facility Using Matched Index of Refraction

    … (3D) replica of the test bed for verification. Noninvasive measurements coupled with a full 3D test bed replica for computational fluid dynamic verification and validation will lead to a full understanding of the microscopic flow phenomena within pebble bed reactors. Texas A&M University is …

    tamu Repository record for Design, Development, and Execution of PIV Measurements on a Randomly Packed Pebble Bed Experimental Facility Using Matched Index of Refraction (opens in a new tab)

  5. Laboratory investigation of electrostatic ion waves modified by parallel -ion -velocity shear

    … parameters and their fluctuations. Direct, noninvasive, measurements of the ion velocity distribution (yielding ion drift velocity and ion temperature) are performed using the laser-induced fluorescence technique. The use of laser-induced fluorescence to determine the radial profile of …

    wvu Repository record for Laboratory investigation of electrostatic ion waves modified by parallel -ion -velocity shear (opens in a new tab)

  6. Novel optical techniques for imaging oxygen and other hemodynamic parameters during physiological events

    … not typically used for imaging, is capable of noninvasive measurements of pO₂. Combining these three techniques has led to the development of an imaging system that could ultimately lead to a better understanding of brain physiology. By combining techniques such as LSCI and MSRI, it becomes …

    texas Repository record for Novel optical techniques for imaging oxygen and other hemodynamic parameters during physiological events (opens in a new tab)

  7. Characterization of cardiovascular-rotary blood pump interaction

    … Fitting of model parameters to the experimental measurements was performed to evaluate the robustness and validity of the mathematical model under the various operating conditions. It was shown from the simulation results that the model was able to reproduce the experimental data in terms of both …

    unsw Repository record for Characterization of cardiovascular-rotary blood pump interaction (opens in a new tab)

  8. Electrical and mechanical activity of the intestine : experimental assessment and biophysical modeling

    … movement. The second one provides local pressure measurements. Only the third method enables noninvasive measurements along the digestive tube. In order to automate the extraction of valuable information contained in the signals recorded by the last method, an approch was proposed based on …

    epfl Repository record for Electrical and mechanical activity of the intestine : experimental assessment and biophysical modeling (opens in a new tab)

  9. Systems for Noninvasive Assessment of Biomechanical Load in the Lower Limb

    … related to joint loading using a synthesis of noninvasive / wearable sensing and machine learning. First, we detail the development of an adjustable-stiffness ankle exoskeleton with multimodal sensing capabilities and use it to explore how humans interact with external elastic loading of the …

    gatech Repository record for Systems for Noninvasive Assessment of Biomechanical Load in the Lower Limb (opens in a new tab)

  10. Nichtinvasive Bestimmung des Herzeitvolumens und verschiedener vaskulärer Parameter im Vergleich zu invasiv erhobenen Parametern bei intensivpflichtigen Patienten

    Da invasive hämodynamische Monitoringverfahren bei verschiedenen Krankheitsbildern standardisiert durchgeführt werden, diese aber auch mit erheblichen Risiken für den Patienten verbunden sind, sollten im Rahmen dieser Studie alternative Messmethoden untersucht werden. Hauptziel der vorliegenden …

    fu-berlin Repository record for Nichtinvasive Bestimmung des Herzeitvolumens und verschiedener vaskulärer Parameter im Vergleich zu invasiv erhobenen Parametern bei intensivpflichtigen Patienten (opens in a new tab)

  11. Magnetic Field Monitoring in the SNS Neutron EDM Experiment

    … gradients inside of the fiducial volume using noninvasive measurements of the field components at discrete locations external to this volume. This document will outline the theoretical framework of our method and present the results of experimental and simulated studies performed and the …

    uky-thes Repository record for Magnetic Field Monitoring in the SNS Neutron EDM Experiment (opens in a new tab)

  12. Hydrodynamic performance of mechanical and biological prosthetic heart valves

    … It is evident from the literature review that noninvasive measurements in a confined area of complex transient geometry, providing critical information relating to valve performance, are indeed scarce. This thesis presents results of an extensive test program aimed at measuring turbulence …

    ubc Repository record for Hydrodynamic performance of mechanical and biological prosthetic heart valves (opens in a new tab)

  13. Dynamics of Transient and Steady-State Responses Evoked by Mechanical Stimulation of the Digits

    … stimulation of the digits can be measured noninvasively by applying dipole analysis to EEG and MEG projected onto a region of postcentral gyrus and were in agreement with known anatomical landmarks near somatosensory area 3b. This experiment was the first to provide evidence of digit …

    mcmaster Repository record for Dynamics of Transient and Steady-State Responses Evoked by Mechanical Stimulation of the Digits (opens in a new tab)

  14. Hemodynamics of ageing, ventricular-arterial coupling and noninvasive assessment of key hemodynamical and cardiac quantities

    … implementation and validation of novel noninvasive tools for monitoring biomarkers of importance (Part III), as well as the evaluation of existing or novel techniques to derive aortic biomechanical properties (Part IV). In Part I, we presented a validated 1D model of the systemic …

    epfl Repository record for Hemodynamics of ageing, ventricular-arterial coupling and noninvasive assessment of key hemodynamical and cardiac quantities (opens in a new tab)

  15. Non-invasive modelling and control of implantable blood pumps for heart failure patients

    … in an IRBP were developed. Non-invasive measurements of power (P) and pump speed (ω) were used with haematocrit (HCT) values as inputs to the flow model while the estimated flow was used with ω as inputs to a head estimation model. Linear regression analysis between estimated and measured …

    unsw Repository record for Non-invasive modelling and control of implantable blood pumps for heart failure patients (opens in a new tab)

  16. Novel Methods for the Detection of Functional Brain Activity using 17O MRI

    … include radiation exposure and invasive measurements such as blood probes to probe cerebral blood flow (CBF). Fick’s principle of arteriovenous oxygen difference [1] connects CMRO2 and CBF via the measure of oxygen extraction fraction (OEF). The main goal of this work is to achieve …

    liege Repository record for Novel Methods for the Detection of Functional Brain Activity using 17O MRI (opens in a new tab)

  17. Accuracy of Masimo Radical-7® Pulse CO-oximetryTM in anaesthetized dogs

    … of CO-Oximetry with pulse oximetry enables noninvasive measurements of the Hb (SpHb) and derived values. Whilst the Masimo pulse COoximeter has given the approval by the Food and Drug Administration (FDA) and European Medical Agency (EMA), there is still debate within the scientific …

    glasgow Repository record for Accuracy of Masimo Radical-7® Pulse CO-oximetryTM in anaesthetized dogs (opens in a new tab)

  18. Diffuse Reflectance Spectroscopy Characterization for Extraction of Tissue Physiological Parameters

    … including blood loss and anemia. Rapid, noninvasive measurements of hemoglobin are important in applications where blood status is reflective of patient well-being, such as in the emergency room, operating room, or the battlefield. Probe-based diffuse reflectance spectroscopy is capable …

    duke Repository record for Diffuse Reflectance Spectroscopy Characterization for Extraction of Tissue Physiological Parameters (opens in a new tab)

  19. Pressure and Flow Wave Propagation in Patient-Specific Models of the Arterial Tree

    … The model predictions were validated with noninvasive measurements of pressure and flow performed in young volunteers. Flow in the large arteries was visualized with magnetic resonance imaging, cerebral flow detected with ultrasound Doppler and blood pressure measured with applanation …

    epfl Repository record for Pressure and Flow Wave Propagation in Patient-Specific Models of the Arterial Tree (opens in a new tab)

  20. Validation of Phase Contrast Flow Quantification and Relaxometry for Cardiovascular Magnetic Resonance Imaging

    … for Magnetic Resonance Imaging (MRI)enables measurements of velocity and flow using a technique called Phase Contrast MagneticResonance (PC-MR), and different time constants of the magnetic resonance signal can bemeasured to characterize different tissue types such as muscle and fat in MR …

    lund Repository record for Validation of Phase Contrast Flow Quantification and Relaxometry for Cardiovascular Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 2