Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"Nonlinear calibration"”.

  1. Complete Measurement System for Measuring High Voltage and Electrical Field Using Slab-Coupled Optical Fiber Sensors

    … highly perturbing to the system under test. Its nonlinear response to high fields requires a new nonlinear calibration technique. A nonlinear calibration method is explained and demonstrated to successfully measure high electric fields, as well as high voltages with dynamic range up to 50 dB. …

    byu Repository record for Complete Measurement System for Measuring High Voltage and Electrical Field Using Slab-Coupled Optical Fiber Sensors (opens in a new tab) Download PDF for Complete Measurement System for Measuring High Voltage and Electrical Field Using Slab-Coupled Optical Fiber Sensors (opens in a new tab)

  2. Non-linear calibration of multi-set differential pulse voltammetry data and evaluation of a pairwise subtraction-based sampling method

    … implementation of a novel sampling technique and nonlinear calibration functions.Results demonstrate that nonlinear calibration can improve interpolation performance, achieving approximately 16–25\% reductions in MAE and RMSE under LOBO validation, but does not consistently generalize to unseen …

    iastate Repository record for Non-linear calibration of multi-set differential pulse voltammetry data and evaluation of a pairwise subtraction-based sampling method (opens in a new tab)

  3. Automated tracking of swimmers in the clean swimming phase of a race

    … from a wide field of view was developed. A nonlinear calibration procedure was used to account for radial distortion. The Root Mean Square Error (RMSE) of reconstructed distances for a wide field of view was 16 x 10-3 m. This compared favourably with a three camera system reported in the …

    sheffield-hallam Download PDF for Automated tracking of swimmers in the clean swimming phase of a race (opens in a new tab)

  4. Low-cost Sensor Array Devices as a Method for Reliable Assessment of Exposure to Traffic-related Air Pollution

    … variability, interference from temperature and nonlinearity. Air quality health index estimation from sensor readings was successfully demonstrated. Three aspects of device reproducibility were evaluated: drift over time, impact of interferences and impact of site-specific mixtures. Three …

    toronto-retro Repository record for Low-cost Sensor Array Devices as a Method for Reliable Assessment of Exposure to Traffic-related Air Pollution (opens in a new tab)

  5. OPTICAL-BASED TACTILE SENSORS FOR MINIMALLY INVASIVE SURGERIES: DESIGN, MODELING, FABRICATION AND VALIDATION

    … to integrate with surgical instruments and show nonlinearity in interaction with biological tissues. In this doctoral study, different optical tactile sensing principles were proposed, modeled, validated and various tactile sensors were fabricated, and experimentally studied to address the …

    concordia Download PDF for OPTICAL-BASED TACTILE SENSORS FOR MINIMALLY INVASIVE SURGERIES: DESIGN, MODELING, FABRICATION AND VALIDATION (opens in a new tab)

  6. Ανάπτυξη μικρο-αναλυτικών και διαγνωστικών μεθόδων με χρήση εντυπωμένων μικρορευστονικών αναλυτικών διατάξεων χαρτιού και νανοϋλικών

    … on the principles of multiple standard additions calibration, and uses calibrant-loaded paper devices, is described. Calibrant-loaded devices have multiple sensing areas pre-loaded with an excess amount of the necessary colorimetric reagents and known amounts (standard solutions) of the tested …

    greece Repository record for Ανάπτυξη μικρο-αναλυτικών και διαγνωστικών μεθόδων με χρήση εντυπωμένων μικρορευστονικών αναλυτικών διατάξεων χαρτιού και νανοϋλικών (opens in a new tab)