Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 127 for “"Nonporous"”.

  1. Ridge preservation comparing the clinical and histologic healing of a mineralized particulate allograft with a nonporous PTFE membrane vs. mineralized particulate xenograft with a collagen plug membrane.

    … allograft (500 to 800 µm) covered with a nonporous PTFE membrane also using a full thickness flap technique (PTFE group). Following tooth extraction, horizontal ridge dimensions were measured with a digital caliper and vertical ridge dimensions were measured from a stent. Each site was …

    louisville Repository record for Ridge preservation comparing the clinical and histologic healing of a mineralized particulate allograft with a nonporous PTFE membrane vs. mineralized particulate xenograft with a collagen plug membrane. (opens in a new tab)

  2. GELATIN-BASED MICROPOROUS INJECTABLE HYDROGELS FOR IN SITU STEM CELL ENCAPSULATION

    … proliferated at a more rapid rate than in a nonporous counterpart, and showed increased immunomodulatory potential. Then, I investigated gelatin microporous hydrogel for the encapsulation of MSCs for bone tissue regeneration. Encapsulated cells more readily differentiated into osteoblasts …

    unh-thes Repository record for GELATIN-BASED MICROPOROUS INJECTABLE HYDROGELS FOR IN SITU STEM CELL ENCAPSULATION (opens in a new tab)

  3. Investigation of Novel Microseparation Techniques

    … from a careful comparison of small porous and nonporous particles show that when the particle size is small enough (< 2 µm), both porous and nonporous particles give excellent performance, and the differences in column efficiencies between porous and nonporous particles become insignificant. …

    byu Repository record for Investigation of Novel Microseparation Techniques (opens in a new tab) Download PDF for Investigation of Novel Microseparation Techniques (opens in a new tab)

  4. Transfer of Microorganisms from Fomites to Hands and Risk Assessment of Contaminated and Disinfected Surfaces

    … transfer studies from various porous and nonporous fomites under different relative humidity condition using non-pathogenic strains of Escherichia coli, Staphylococcus aureus, MS2 coliphage, Bacillus thuringiensis spores, and poliovirus 1; to evaluate the persistence of bacteria and …

    arizona-thes Repository record for Transfer of Microorganisms from Fomites to Hands and Risk Assessment of Contaminated and Disinfected Surfaces (opens in a new tab)

  5. Flow modification over a backward facing step

    … flow over a backward facing step. Nonporous flat and curved deflectors and porous flat deflectors were mounted in various positions near the edge of the step and the flow patterns recorded using both still and video photography. The deflectors were mounted at varying separations …

    nps Repository record for Flow modification over a backward facing step (opens in a new tab)

  6. Chromatography of Latex Particles in Packed Columns (Hydrodynamic, Dispersion)

    … that involve packed columns with either nonporous packing material (termed hydrodynamic chromatography) or porous packing material (termed porous hydrodynamic chromatography or size exclusion chromatography) were studied.

    uiuc Repository record for Chromatography of Latex Particles in Packed Columns (Hydrodynamic, Dispersion) (opens in a new tab)

  7. Removal of gasoline-based hydrocarbons by vapor permeation membranes

    … (VOCs) from the vented air streams through nonporous hydrophobic polymeric membranes subjected to vacuum on the permeate side and then condensing these organics from the permeate. Such a vapor permeation process employing spiral-wound membranes has already been commercialized for VOCs. In …

    njit Repository record for Removal of gasoline-based hydrocarbons by vapor permeation membranes (opens in a new tab)

  8. Removal and recovery of VOCs and OILs from surfactant-flushed recovered water by membrane permeation

    … of TCE which diffuses through the pores and the nonporous silicone skin on the outer surface of fibers. The oil wets the pores and is removed by permeation through the nonporous silicone rubber skin by applying a positive feed pressure.The presence of oil affected the flux of TCE but the water …

    njit Repository record for Removal and recovery of VOCs and OILs from surfactant-flushed recovered water by membrane permeation (opens in a new tab)

  9. Ultra-Flexible Piezoresistive Nanocomposite Foam Sensing Systems for Force Mapping

    … for a better understanding of porous and nonporous nanocomposites’ mechanical behavior, micromechanical modeling approaches were used to predict their elastic modulus.The first phase of this research work was focused on the fabrication and characterization of mechanical and electrical …

    toronto-retro Repository record for Ultra-Flexible Piezoresistive Nanocomposite Foam Sensing Systems for Force Mapping (opens in a new tab)

  10. Improving Physical and Biochemical Properties of Gelatin Microgels for Tissue Engineering

    … bulk mechanical properties comparable to nonporous gelatin microgel assemblies. Human dermal fibroblasts infiltrated the internal pores, and RNA sequencing indicated distinct transcriptional responses of inflammatory-signal-primed mesenchymal stem cells in porous and nonporous …

    unh-thes Repository record for Improving Physical and Biochemical Properties of Gelatin Microgels for Tissue Engineering (opens in a new tab)

  11. Optoelectronically Active Metal-Inorganic Frameworks and Supramolecular Extended Solids

    … frameworks (MIFs), a new class of porous and nonporous materials using inorganic complexes as linkers, in lieu of traditional organic linkers in MOFs is reported. Besides novel MIF regimes, the previously described fluorous MOF "FMOF-1", is re-categorized herein as "F-MIF1". F-MIF-1 is …

    unt Repository record for Optoelectronically Active Metal-Inorganic Frameworks and Supramolecular Extended Solids (opens in a new tab)

  12. Photosensitization and Analytical Study on Reactive Oxygen Intermediates: Self-sorting Surface Radicals and “On-off” Sensitizer Function Mechanisms

    … adsorbed with porous milliparticles, and nonporous microparticles, and nonporous nanoparticles to determine the weight of particles loaded onto the superhydrophobic surface. Desorption of the sensitizer is found to be a key component.

    cuny-grad Repository record for Photosensitization and Analytical Study on Reactive Oxygen Intermediates: Self-sorting Surface Radicals and “On-off” Sensitizer Function Mechanisms (opens in a new tab)

  13. Persistence of Enteric Viruses on Surfaces under Varying Environmental Conditions

    … surface sampling method for virus recovery from nonporous food contact surfaces (FCS) for further application in environmental persistence studies under varying temperature and relative humidity (RH) combinations. Initially, feline calicivirus (FCV), hNoVs (GI.1; GII.17), AiV, and Tulane virus …

    arkansas Repository record for Persistence of Enteric Viruses on Surfaces under Varying Environmental Conditions (opens in a new tab)

  14. Evaluation of wet-vacuum technique versus traditional methods for collection of biological crime scene samples

    … analysis. Samples were collected from porous and nonporous surfaces; the efficacy of each collection method was evaluated with a colorimetric presumptive blood test. To evaluate each collection method, dilutions containing from 0.25 nl to 25 μl human blood were spotted on common substrate …

    bu Repository record for Evaluation of wet-vacuum technique versus traditional methods for collection of biological crime scene samples (opens in a new tab)

  15. Membrane-based reactors for ozonolysis of organic pollutants in aqueous and gaseous streams

    … stream was exposed to O_3/O_2 by means of a nonporous silicone capillary membrane. Experiments conducted to ascertain the effect of long-term exposure of O_3 on the membranes measured the permeability of O_2/N_2 across the membrane before and after exposure to O_3; the permeability of O_3 …

    njit Repository record for Membrane-based reactors for ozonolysis of organic pollutants in aqueous and gaseous streams (opens in a new tab)

  16. An Evaluation of Tape for the Collection of Ignitable Liquid Residues from Non-Porous and Porous Surfaces

    … are investigated for direct ILR collection from nonporous and porous surfaces. Tape is a cost-effective absorbent material selected because of its sturdy but flexible backing. Additionally, the adhesive is typically composed of nonpolar films and resins which are chemically compatible with the …

    eku Repository record for An Evaluation of Tape for the Collection of Ignitable Liquid Residues from Non-Porous and Porous Surfaces (opens in a new tab)

  17. Transient heat and mass transfer in two monolith reactor passage geometries

    … where the reactants diffuse and react, and the nonporous solid substrate layer. The concentration and temperature profiles are computed using a Fourier series solution for the fluid equations and a finite difference method of lines algorithm for the solid equations. Inter- and intra-phase heat …

    rice Repository record for Transient heat and mass transfer in two monolith reactor passage geometries (opens in a new tab)

  18. Charge Transport Phenomena in Fe-Based High Surface Area Materials

    … conductivity in mesoporous media and nonporous conductive polymers we expect such phenomena to be heightened and unique at the interfacial extremes that microporous materials and 2D Van Der Waals (vdw) materials possess. We utilize the unique properties of Fe-based materials to design …

    oregon Repository record for Charge Transport Phenomena in Fe-Based High Surface Area Materials (opens in a new tab)

Page 1 of 7