Compliance, relaxation and creep recovery of normal strength concrete.
… the long term serviceability of reinforced concrete structures requires an appropriate description of the mechanical properties of concrete. Among the long duration properties of concrete are shrinkage and creep of concrete. At relative humidities less than 96--99% concrete shrinks. For …
-
A novel application of mineral powders in normal strength concrete
… powders to replace a part of the cement in concrete and the effects of replacement on the properties of fresh and hardened concrete were studied. In the past, studies of the influence of fillers in concrete have mainly been focused on high strength, self-compacting and high-performance …
-
A unified bond theory, probabilistic meso-scale modeling, and experimental validation of deformed steel rebar in normal strength concrete
"Bond between deformed rebar and concrete is affected by rebar deformation pattern, concrete properties, concrete confinement, and rebar-concrete interfacial properties. Two distinct groups of bond models were traditionally developed based on the dominant effects of concrete splitting and …
-
Preliminary Investigation of Ultra-High Performance Concrete Behavior at High Strain Rates using the Split-Hopkinson Pressure Bar
Ultra-high performance concrete (UHPC) displays several enhanced material properties compared to normal strength concrete (NSC). In past research, Split-Hopkinson pressure bar (SHPB) tests have been used for normal strength concrete to determine material behavior at high strain rates. The behavior …
-
Seismic response of high-strength concrete beam-column-slab specimens
The effects of high-strength concrete on the seismic performance of reinforced concrete exterior beam-column-slab subassemblages were investigated by comparing the behaviour of three full-scale specimens. Two specimens, one constructed with normal-strength concrete and one constructed with …
-
Freeze-Thaw, Surface Resistivity, and High Temperature Performance of Local UHPC
<p>Ultra-High Performance Concrete (UHPC) is an important material for modern structures, due to its high strength properties in regards to tension, compression and ductility. UHPC is well known to distinctly surpass common-use concrete in strength, but its relation to this concrete in durability …
-
Behaviour of square high-strength concrete columns under load reversals.
Strength and deformation characteristics of 10 square confined high-strength concrete columns were investigated. Properties of columns were selected to allow assessment of the importance of confinement parameters for high-strength concrete columns. The specimens were tested under constant axial …
-
Effect of confinement on the response of ductile shear walls
… provided in boundary elements. One specimen used normal-strength concrete, and the other used high-strength concrete. A number of confinement analytical models were selected to predict the behaviour of each specimen. The test data of two moderately confined shear walls (Liu 2004) was used to …
-
Ductility in reinforced concrete columns
… test results are used to study the behaviour of concrete specimens. Based on existing test results in the literature, a new model was proposed for the axial stress versus strain response of normal and high strength concretes. This model is capable of predicting the concrete stress versus strain …
-
An analytical study on minimum confinement in spiral columns
… given in the codes is derived by equating the strength at the second peak to the strength at the first peak for spiral columns tested under uniaxial load. In this study, specimen behavior under combined bending and axial load was taken as basis while deriving proposed equations. Analyses were …
-
Seismic design recommendations for high-strength concrete beam-to-column connections.
… the loading condition. The value of compressive strength f'(c) used in the above expression should not exceed 6000 psi. This limitation causes considerable difficulty in the design of high-strength concrete frames. An experimental study of twelve large-scale exterior beam to column subassemblies …
-
Behaviour of steel fibre reinforced high performance concrete under biaxial loading conditions
… of steel fibre reinforced high performance concrete (SFRHPC) under biaxial loading conditions. Also included are constitutive models to enable numerical predictions of the strength behaviour of such a material. Within the experimental stage a large biaxial test machine was designed and …
-
Time dependent creep response of ultra-high-performance concrete without fiber reinforcing
… modern infrastructure, ultra-high-performance concrete (UHPC) and its mechanical properties have been the focus of many research projects and experiments. Understanding the advantages of this relatively new material can provide immense benefits in design of global infrastructure. The purpose of …
-
Experimental evaluation of maximum debonding strain in thick CFRP layers for flexural strengthening
… reinforced polymer (CFRP) is widely used for strengthening RC structures; however, the externally bonded reinforcement (EBR) method is often governed by premature debonding at the CFRP-concrete interface, preventing CFRP from reaching its full tensile capacity. Current design provisions limit …
-
The effects of alkali-aggregate reactivity on the mechanical properties of concrete
… sodium and potassium alkaline components in the concrete mix and active mineral constituents of some aggregates. The reaction results in the formation of a gel which absorbs water, expands, and therefore exerts internal pressures which sometimes can be far in excess of that which concrete can …
-
Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement
… reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs …
-
Strain-Based Assessment of Tension Lap Splices in Ultra-High-Performance Concrete Using Distributed Fiber Optic Sensing
… seen as a nuisance. The collapse of a reinforced concrete structure following an earthquake serves as a powerful reminder of their true role. Ultra-High-Performance Concrete (UHPC), known for its compressive strength, offers increased splitting resistance due to its steel fiber content. This study …
-
Strain-Based Assessment of Tension Lap Splices in Ultra-High-Performance Concrete Using Distributed Fiber Optic Sensing
… seen as a nuisance. The collapse of a reinforced concrete structure following an earthquake serves as a powerful reminder of their true role. Ultra-High-Performance Concrete (UHPC), known for its compressive strength, offers increased splitting resistance due to its steel fiber content. This study …
-
Strain-Based Assessment of Tension Lap Splices in Ultra-High-Performance Concrete Using Distributed Fiber Optic Sensing
… seen as a nuisance. The collapse of a reinforced concrete structure following an earthquake serves as a powerful reminder of their true role. Ultra-High-Performance Concrete (UHPC), known for its compressive strength, offers increased splitting resistance due to its steel fiber content. This study …