Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 55 for “"Numerical aperture (NA)"”

  1. Simulation Of Electromagnetic Diffraction With Tissue Scatering For High Numerical- Aperture Optical Systems

    … we discuss the propagation of light with low numerical aperture and high numerical aperture objectives, with or without scattering media. The point spread function (PSF) of a focused beam is studied for low and high aperture situations without scattering medium. Based on the result of other …

    cornell Repository record for Simulation Of Electromagnetic Diffraction With Tissue Scatering For High Numerical- Aperture Optical Systems (opens in a new tab)

  2. Achromatic metalens imaging for camera system

    … provide a larger bending angle as well as higher numerical aperture(NA) compared with traditional lens. In this dissertation, a novel design of metalens is established in Lumerical FDTD simulation, which is used to focus a mid-infrared band plane wave. In order to establish that metalens, a number …

    nanyang Repository record for Achromatic metalens imaging for camera system (opens in a new tab)

  3. A Vertically Loaded Diamond Microdisk Resonator (VLDMoRt) towards a Scalable Quantum Networks

    … of vertically-loaded diamond microdisk resonator (VLDMoRt). It couples to a nitrogen-vacancy (NV) center in diamond for efficient collection of fluorescence emission into low numerical aperture (NA) free-space modes. The VLDMoRt achieves a Purcell enhancement of 172 with 39% of the emitted …

    mit Repository record for A Vertically Loaded Diamond Microdisk Resonator (VLDMoRt) towards a Scalable Quantum Networks (opens in a new tab)

  4. SYNTHETIC APERTURE OPTICAL IMAGING INTERFEROMETRIC MICROSCOPY WITH IMPROVED IMAGE QUALITY

    … Microscopy (IIM), which uses a low numerical aperture (NA) objective lens to achieve resolution equivalent to that of a high-NA objective lens with multiple sub-images. Along with the resolution enhancement challenge, IIM often suffers from poor image quality. In this dissertation, …

    unm Repository record for SYNTHETIC APERTURE OPTICAL IMAGING INTERFEROMETRIC MICROSCOPY WITH IMPROVED IMAGE QUALITY (opens in a new tab)

  5. Systems, Models, and Simulation for Novel Microfabrication of Silicon Carbide and Metal Mesh Filters

    … unification of femtosecond laser pulses, high numerical aperture (NA) objective lenses, and system power and motion control, a system capable of achieving arbitrary 3D features without line-of-sight with aspect ratios up to 109:1 in SiC is developed. Additionally, a model of a direct-write …

    byu Repository record for Systems, Models, and Simulation for Novel Microfabrication of Silicon Carbide and Metal Mesh Filters (opens in a new tab)

  6. Aukštos skyros funkcinių mikrodarinių formavimas ir taikymai /

    … It was demonstrated a technological combination of selective laser etching and multiphoton polymerization technologies into a novel type micromechanical sensor for the investigation of polymer mechanical properties in different surrounding mediums (liquids, air). Moreover, it was …

    vilnius Repository record for Aukštos skyros funkcinių mikrodarinių formavimas ir taikymai / (opens in a new tab)

  7. Optically-Transparent Focused Transducers on Polymer Substrates for Photoacoustic Microscopy

    … optical and acoustical beams. However, conventional ultrasound transducers for photoacoustic (PA) signal detection are not optically transparent, which could block the passage of the laser beam for effective PA excitation. In this research, a new optically-transparent focused ultrasound …

    tamu Repository record for Optically-Transparent Focused Transducers on Polymer Substrates for Photoacoustic Microscopy (opens in a new tab)

  8. LIGHT-ATOM COUPLING WITH 4PI MICROSCOPY

    … free space. Our approach utilises a pair of high numerical aperture (NA=0.75) lenses to tightly focus light onto single 87Rb atoms. Operating near the diffraction limit, the length scale of the light field approaches that of the thermal motion of trapped atoms. Therefore, we focus on our studies …

    nus Repository record for LIGHT-ATOM COUPLING WITH 4PI MICROSCOPY (opens in a new tab)

  9. Studies on digital holography for aspheric surface measurement

    … technique for 3D precision measurement. By numerical reconstruction and propagation of a digital hologram, the optical field from an object and thus the amplitude and phase can be quantitatively reconstructed. The quantitative phase allows determination of the surface topography of the …

    nanyang Repository record for Studies on digital holography for aspheric surface measurement (opens in a new tab)

  10. Improvement of digital lensless holographic microscopy for the visualization of biosamples

    … an attractive, portable, and cost-effective alternative for observing microscopic biological samples. Despite the simplicity of its implementation, the hardware used to record the digital holograms has limitations that directly affect the visualization of biological samples. In this master’s …

    un-colombia Repository record for Improvement of digital lensless holographic microscopy for the visualization of biosamples (opens in a new tab)

  11. Design and Fabrication of Snapshot Imaging Spectrometers for Biomedical and Remote Sensing Applications

    In this work, two advanced snapshot field-integral hyperspectral imaging spectrometers are presented. The first system is based on image mapping mirrors and achieves significantly increased datacube size and dynamic range compared to previous generations. This benefits from a novel design and …

    rice Repository record for Design and Fabrication of Snapshot Imaging Spectrometers for Biomedical and Remote Sensing Applications (opens in a new tab)

  12. Image-based EUVL Aberration Metrology

    A significant factor in the degradation of nanolithographic image fidelity is optical wavefront aberration. As resolution of nanolithography systems increases, effects of wavefront aberrations on aerial image become more influential. The tolerance of such aberrations is governed by the requirements …

    rit Repository record for Image-based EUVL Aberration Metrology (opens in a new tab)

  13. Design of miniature microscope objective optics for biomedical imaging

    … is both similar and different from conventional microscope objective. The design and construction of two miniature microscope objectives are presented in this dissertation. The first one is a high numerical aperture (NA), water-immersion objective and it is a part of a fiber confocal …

    arizona-thes Repository record for Design of miniature microscope objective optics for biomedical imaging (opens in a new tab)

  14. Resolution improvement in optical microscopy by use of multi-beam interferometric illumination

    In conventional optical microscopy, the numerical aperture (NA) of the objective lens intrinsically links the resolution, depth of field (DOF), working distance (WD) and field of view (FOV). In a diffraction-limited system, changing the NA to improve resolution is not possible without degrading the …

    mit Repository record for Resolution improvement in optical microscopy by use of multi-beam interferometric illumination (opens in a new tab)

  15. Advanced fibre-based endoscopy for biophotonics applications

    … with footprints far bellow those of conventional endoscopes, as well as enhanced spatial resolution up to the diffraction limit de-termined by the numerical aperture (NA) of the fibre.<br/><br/>In this Thesis, high-resolution focussing is demonstrated with unprecedented ability across novel …

    dundee Repository record for Advanced fibre-based endoscopy for biophotonics applications (opens in a new tab)

  16. Engineering Electromagnetic Wave Properties Using Subwavelength Antennas Structures

    With extraordinary properties, generation of complex electromagnetic field based on novel subwavelength antennas structures has attracted great attentions in many areas of modern nano science and technology, such as compact RF sensors, micro-wave receivers and nano-antenna-based optical/IR …

    ohiolink Repository record for Engineering Electromagnetic Wave Properties Using Subwavelength Antennas Structures (opens in a new tab)

  17. A new apparatus for quantum simulation with dipolar erbium atoms

    … such as large magnetic moment, rich Feshbach resonance, a wide range of excitation spectrum, and long-lived spin–orbit coupling. Experiments including extended Bose–Hubbard model [1], quantum droplets [2, 3], and supersolid phases [4, 5, 6] have been actively studied with the quantum degenerate …

    hkust Repository record for A new apparatus for quantum simulation with dipolar erbium atoms (opens in a new tab)

  18. In vivo imaging of the retinal diseases progression at subcellular resolution in the mouse model

    … issue globally. It has been reported that retinal diseases are the most and second most cause of irreversible blindness in developed and developing countries. Although it has been proven that structural and functional alterations of retina are associated with a variety of ocular disorders, the …

    hkust Repository record for In vivo imaging of the retinal diseases progression at subcellular resolution in the mouse model (opens in a new tab)

  19. Depth of field enhancement of a particle analyzer microscope using wave-front coding

    In this thesis we present an analytical solution to the problem of improving the depth of field (DOF) of a certain large magnification imaging system with a high numerical aperture (NA), illuminated with an incoherent source of light. As there is a definite trade-off between the focal depth and …

    mcgill Repository record for Depth of field enhancement of a particle analyzer microscope using wave-front coding (opens in a new tab)

  20. Ultra-high-resolution optical imaging for silicon integrated-circuit inspection

    … of ultra-high-resolution two- and three-dimensional images of a silicon flip-chip using a 1.55μm modelocked Er:fibre laser. This technology provided diffraction-limited lateral and axial resolutions of 166nm and 100nm, respectively - an order of magnitude improvement over previous TOBIC imaging …

    heriot-watt Repository record for Ultra-high-resolution optical imaging for silicon integrated-circuit inspection (opens in a new tab)

Page 1 of 3