Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 27 for “"Nyquist Limit"”
-
Quantifizierung von Mitralinsuffizienz unter Verwendung von Color flow Doppler und Baseline shift
… (TEE). For color-flow Doppler (CF) measurements Nyquist limit of 50–60 cm/s is recommended. Aim of the study was to investigate the effectiveness of a baseline shift of the Nyquist limit for these measurements. After a comprehensive 2-dimensional (2D) TEE examination, the mitral regurgitation jet …
-
Visual Vibrometry as a Method for Non Destructive Evalution
… insights into structural behaviour but have limitations. Accelerometers can influence dynamic behaviour through contact measurements, while LDV is prohibitively expensive. Visual vibrometry addresses these issues using standard cameras and computer vision algorithms, offering potential for …
-
Evaluation of phase retrieval in a compressive computational ghost imaging setup
… to recover images with far less data than the Nyquist limit dictates. However, the retrieval in the image of certain properties of the object, such as its Fourier phase spectrum, has not been studied using ghost imaging setups. This monograph precisely presents this type of studies. …
-
Ptychographic Imaging of Mixed States
… that are sampled grossly below the conventional Nyquist limit, the automatic correction of detector imperfections, the imaging of mixed states through multiple wavelength illumination, and the reconstruction of partially coherent data in the STEM configuration through the deconvolution of an …
-
Analytical time domain electromagnetic field propagators and closed-form solutions for transmission lines
… dispersion down to the two points per wavelength Nyquist limit. Examples are presented showing that exceptionally accurate results are obtained for lossy single and multiconductor transmission lines. The method is extended to represent the general solution to Maxwell’s differential equations in …
-
Multidimensional random sampling for Fourier transform estimation
… imposes the sampling density of at least the Nyquist density. Otherwise, alias frequencies occur in the processed bandwidth which can lead to irresolvable processing problems. Random sampling can mitigate Nyquist limit that classical uniform-sampling-based approaches endure, for the purpose of …
-
Subarray selection in octave arrays
… Array aperture of the highest octave band is limited to uniform line array (ULA) segment at the center. Forming a sparse array layout for the highest frequency band by using some of the remaining elements apart from ULA could bring some advantages such as higher array gain and better detection …
-
TECHNIQUE ADVANCES AND APPLICATIONS OF CRYO-ELECTRON-MICROSCOPY FOR THE STUDY OF VITRIFIED BIOLOGICAL SYSTEMS
… TEM techniques are highlighted, along with the limited applica- bility of conventional STEM for high-resolution structural determination due to collection efficiency limitations. To address these challenges, a 4D-STEM technique, tilt-corrected bright-field STEM (tcBF-STEM) is introduced, aiming …
-
Ambient noise levels off the coast of Northern Labrador
… water depth is 500 meters. High biodiversity and limited shipping activity make this an area of interest. At the mooring location, tidally driven currents are driven to speeds of up to 50 cm/s. The high current speeds result in a significant tilting of the mooring, with the instrument often …
-
Image improvement using dynamic optical low-pass filter
… response characteristics that exceed the Nyquist limit of the sensor, which, if not properly addressed, results in aliasing artifacts in the captured image. Most contemporary still and video cameras employ various optically birefringent materials as optical low-pass filters (OLPF) in order …
-
Extending the measurement range of high-speed speckle pattern interferometry
… at which the interferogram is sampled at the Nyquist limit (vNyq). The flexibility of the CMOS detector readout was used to identify regions of interest with full-field time-averaged measurements and then to interrogate those regions with time-resolved measurements sampled at up to 70 kHz. To …
-
Improving the Spectral Efficiency of Modulation on Conjugate-Reciprocal Zeros (MOCZ) for Non-Coherent Short Packet Communications
… rate loss as compared to the channel capacity limit. Hence, in this thesis, we aim to increase the spectral efficiency of MOCZ. We improve the spectral efficiency of MOCZ by proposing a technique named as spectrally efficient modulation on conjugate reciprocal zeros (SE-MOCZ) which combines …
-
Effects of Active Vision and Internal State on Drosophila Visual Behaviour
… to 2° wavelength gratings, well below the 4-5° Nyquist limit. Notably, this behaviour is observable exclusively through head-optomotor responses, emphasizing the significance of active sensing mechanisms in fly vision. The characteristics of anti-optomotor behaviour suggest that a saccadic-like …
-
Detection of Copies of Digital Audio Recordings for Forensic Purposes
… filter with a cut off frequency close to the Nyquist limit. It will be shown that in its simplest form, the recorded data may be considered to be an acoustic signal added to white noise produced from signal conditioning circuits and convolved with the low-pass response of the recording system. …
-
Structural and Functional Optical Coherence Tomography Imaging of the Colon
… while laterally sampling the tissue at the Nyquist limit. First, I describe the design of a miniature endoscope and the integration of this probe with a commercial OCT system. Then I describe the development of two OCT imaging methods, one structural and one functional, that could be used …
-
Sparse MRI and CT Reconstruction
… (CT) are investigated. For medical CT, a limited number of views (sparse-view) is an option for whether reducing the amount of ionizing radiation or the screening time and the cost of the procedure. In applications such as non-destructive testing or inspection of large objects, like a …
-
Study and implementation of fast compressive 3-D total focusing method ultrasonic imaging using 2-D sparse arrays
… a 2-D imaging context using linear array probes, limitations arise concerning the identification of defects, particularly in scenarios with random orientations such as cracks, demanding the necessity for 3-D imaging solutions. The study addresses the challenges associated with the use of …
-
Optical Signal Processing and Pulse Shaping for Wavelength Multiplexed High Speed Communication Systems
… efficient way in order to reach the theoretical Nyquist limit of transmission links. A promising technique is the use of sinc-shaped Nyquist pulses that enable multiplexing channels in time domain with no inter-symbol interference (ISI) while exhibiting a rectangular spectrumthat alleviates the …
-
Application of Wavelets to Filtering and Analysis of Self-Similar Signals
… about the signal by applying a function of a limited duration, also called a wavelet, to the signal. As with the Fourier transform, the discrete wavelet transform has an inverse transform, which allows us to make changes in a signal in the wavelet domain and then transform it back in the time …
-
Sparse reconstruction of multidimensional light transport signals
… low frequencies, in fact, well below the Nyquist limit. This is possible by exploiting some a priori knowledge, namely, the fact that the signal can be sparsely represented in some alternative space, other than the canonical time/space reference frame. Over the last decade sparse …
Page 1 of 2