Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 28 for “"OAR sparing"”
-
A knowledge-based quantitative approach to characterize treatment plan quality: application to prostate VMAT planning
… constraints for the targets and organs at risk (OARs) repeatedly in a trial and error treatment planning process to optimize clinically acceptable plans. However, using unachievable constraints may lead to sub-optimal plans. As a result, plan quality varies among planners according to their level …
-
Developing Intelligent Reinforcement Learning Bots for Radiation Therapy Treatment Planning
… between target coverage and organ-at-risk (OAR) sparing. A deep reinforcement learning (DRL) agent was developed to directly interact with a clinical treatment planning system to perform inverse optimization. During each optimization process, intermediate dosimetric endpoints, dose–volume …
-
Inverse Treatment Planning of Nasopharyngeal Carcinoma in Gamma Knife Radiotherapy
… are employed to increase the tumor dose while sparing the surrounding organs at risk (OAR). Radiosurgical devices such as the Leksell Gamma Knife (GK) are known for their sharp dose fall-off outside the tumor region resulting in minimal dose to the healthy brain. Although this device was …
-
The Dosimetric Importance of Six Degree of Freedom Couch End to End Quality Assurance for SRS/SBRT Treatments when Comparing Intensity Modulated Radiation Therapy to Volumetric Modulated Arc Therapy
… the low dose radiation volume as well as improve OAR sparing.For the 6 DOF couch QA, graph paper is placed on the anterior and right lateral sides of the VisionRT OSMS Cube Phantom. Each rotational shift is then applied individually, with a 3 degree shift in the positive and negative directions …
-
Dosimetric comparison between 2D and 3D planned intracavitary brachytherapy for cervical cancer at Groote Schuur Hospital
… estimating the dose to organs at risk (OARs) and the clinical target volume (CTV). The global standard of care has shifted toward three-dimensional (3D) image-based planning using CT or MRI, allowing for improved visualization of target structures and OARs, as well as optimized dose …
-
Intensity Modulated Proton Therapy for Hepatocellular Carcinoma
… which efficiently spare the organs-at-risk (OARs) have been generated. The challenge with using IMPT when treating HCC however, is that the tumor moves over time due to breathing and the sensitive spatio-temporal resolution of the IMPT is therefore compromised in the treatment delivery, …
-
Sensitivity of plan re-optimizaton to errors in deformable image registration in online adaptive image-guided radiation therapy
… is a challenge. Mapping accurate organ at risk (OAR) contours through DIR and auto-segmentation is especially challenging for abdomen and pelvis treatment sites known to have significant interfractionaanatomical variations. While others have studied the accuracy of auto-deformed contours and …
-
Investigation of automatic treatment planning (ATP) optimization using an Adaptative Neuro-Fuzzy AI system
… histogram (DVH) metrics, improved organ-at-risk (OAR) sparing, and enhanced target dose conformity. The results highlight ANFIS's potential in reducing reliance on manual tuning, increasing planning efficiency, and providing interpretable decision-making insights for clinical …
-
The potential of 4π radiotherapy: a new era for improving outcomes in challenging paediatric cases? A comparative dosimetric analysis
… and minimize irradiation to organs at risk (OARs). In pediatric neuro-oncology, conventional modalities such as VMAT and IMRT are widely adopted; however, reducing toxicity to developing healthy tissues remains a major clinical challenge. This study explores the dosimetric benefits of 4π …
-
Improved MRI-based radiotherapy treatment planning of glioblastoma brain tumours
… planning, resulting in improved organ-at-risk (OAR) sparing. Results from the framework extension study further showed that combining BTVs with personalized CTVs can significantly reduce irradiated volume while maintaining tumour coverage. In summary, this thesis demonstrates the clinical …
-
Optimization of Radiation Therapy in Time-Dependent Anatomy
… 4D- dose are not significant in organs at risk (OARs), however, 4D-dose to a moving lung cancer target can deviate from 3D-dose. These differences imply that optimization of the 4D-dose through multiple-anatomy optimization (MAO) can improve radiation therapy in 4D-anatomy. MAO incorporates …
-
Towards the Clinical Implementation of Online Adaptive Radiation Therapy for Prostate Cancer
… based on daily target coverage, Organ-at-Risk (OAR) sparing and implementation efficiency. Simulated treatment courses for 18 patients with re-optimization alone, re-positioning alone and AIGRT shows that AIGRT offers reliable daily target coverage that is highly comparable to re-optimization …
-
Inter-fraction Variability of High-Risk Clinical Target Volume (HR-CTV) and Organs at Risk (OARs) in Cervical Cancer High-Dose-Rate (HDR) Brachytherapy
… target volume (HR-CTV) and organs at risk (OARs) are contoured on MRI. To save time and resources without compromising target coverage or OAR sparing and treatment quality, this study aimed to retrospectively identify patient subgroups that would benefit from adaptive treatment planning (MR …
-
Decision-support strategies to improve radiotherapy outcomes in prostate and gynecological cancer treatment planning
… sensitive structures known as organs at risk (OARs). Achieving this balance is particularly important in prostate and gynecological cancers where critical structures are located in close proximity to the target. This thesis investigates decision-support strategies that aim to improve the …
-
Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations of Microdosimetry
… to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro experiments, that show RBE varies, typically as a function of dose averaged linear energy transfer (LETD). There are two goals of this work. The first …
-
Plan Quality and Isotoxic Dose Escalation Investigation Using a 0.35T MR-Linac System in Ablative 5-Fraction Stereotactic Magnetic Resonance-Guided Radiation Therapy (MRgRT) for Primary Pancreatic Cancer
… prescription dose (PD) and organ at risk (OAR) constraints (Plan 1), following SMART trial’s OAR constraints but with the original PD (Plan 2), and, starting with Plan 2, following an isotoxic dose escalation strategy where dose was escalated until any one of the SMART trial’s OAR …
-
Evaluation of two adaptive radiotherapy workflows and their benefits for stage III non-small cell lung cancer patients using cone-beam computed tomography-based synthetic computed tomography
… esophagus are the main limiting organs at risk (OAR), which are susceptible to pneumonitis, cardiovascular toxicity, and acute esophagitis due to high radiation doses. Modern concurrent chemoradiotherapy results in 5-year overall survival rates of 32-33%, which can be increased to approximately …
-
Patient-Specific Monte Carlo Dosimetric Evaluation of Heterogeneity effects in Tile - based Cesium-131 Permanent Intracranial Brachytherapy with Clinical Validation
… on target coverage and organ-at-risks (OAR) sparing using a high-fidelity MC framework with retrospective patient CT DICOM datasets of intracranial ¹³¹Cs implants. Furthermore, the theoretical applicability of the Linear Boltzmann Transport Equation (LBTE) is explored as a deterministic …
-
Automated Treatment Planning Framework for Cervical Cancer in Brachytherapy
… exposure to surrounding organs at risk (OAR). However, due to the inherent nature of ionizing radiation, some dose to OARs is unavoidable, creating a fundamentally conflicting objective in treatment planning: maximizing tumor coverage while minimizing OAR dose. This characterizes the …
-
Fractionated Treatment Planning of Radiation Therapy Considering Biological Response
… healthy organs called organs at risk (OARs). In conventional practice, the treatment policy is to deliver an equal amount of radiation dose to the patient over multiple treatment sessions. Such an approach neglects different uncertainties associated with tumor dynamics, biological …
Page 1 of 2