Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 14 of 14 for “"ONSD"”.
-
The Effect of Surgical and Anesthetic Parameters on Intracranial Pressure as Measured by Optic Nerve Sheath Diameter
… measured optic nerve sheath diameter (US-ONSD) serves as a surrogate for intracranial pressure (ICP), avoiding the need for invasive intracranial monitoring. This thesis primarily aims to investigate the effects of laparoscopy on optic nerve sheath diameter (ONSD), and thus ICP in healthy …
-
Effects of Head-Down Tilt on Optic Nerve Sheath Diameter in Healthy Subjects
… effect of HDT on optic nerve sheath diameter (ONSD) in normal subjects. METHODS Twenty-six healthy adults (age 28 (4.7) years) participated in seated and 6° HDT visits. For each visit, subjects presented at 11am for baseline seated scans and then maintained a seated or 6° HDT posture from 12pm …
-
Determinación del promedio del diámetro de la vaina del nervio óptico en voluntarios sanos de un hospital de Bogotá
… the average optic nerve sheath diameter (ONSD), in a healthy adult population of the city of Bogotá using the CLOSED protocol and adjustment for the transverse diameter of the eyeball (ONSD/TED). Methodology: The ONSD was measured with the application of the CLOSED protocol and ONSD/TED o …
-
Der Optikusnervenscheidendurchmesser als Instrument zur Prognoseeinschätzung bei Patienten mit hypoxischer Enzephalopathie nach erfolgreicher Reanimation
… des Optikusnervenscheidendurchmessers (ONSD) mittels transorbitaler Sonographie in der Diagnostik unterschiedlicher intrakranieller Erkrankungen bereits bewährt hat. Das Krankheitsbild der HIE wurde als weiteres mögliches Einsatzgebiet des ONSD jedoch bisher nicht untersucht. Ziel dieser …
-
Utilization of Orbital Ultrasound and Optical Coherence Tomography in Papilledema and Pseudopapilledema patients
… A-scan to measure optic nerve sheath diameter (ONSD). If ONSD at primary gaze exceeded normal limits (4.2 mm), a 30° test was performed to measure the ONSD at 30° lateral gaze. A Cirrus OCT Optic Disc Cube 200x200 scan was used to obtain the retinal nerve fiber layer thickness (RNFLT). Results: …
-
Ο λόγος της διαμέτρου του ελύτρου του οπτικού νεύρου προς την εγκάρσια διάμετρο του οφθαλμού και η θνητότητα, σε ασθενείς της ΜΕΘ με κρανιοεγκεφαλική κάκωση (ΚΕΚ) και παρακολούθηση ενδοεγκεφαλικής πίεσης
… της διαμέτρου του ελύτρου του οπτικού νεύρου (ONSD), ως ένδειξη αυξημένης ενδοκράνιας πίεσης (ICP), αποτελεί μια ολοένα και περισσότερο μελετούμενη μη επεμβατική μέθοδο. Ωστόσο, η αξιοπιστία της χρήζει περαιτέρω τεκμηρίωσης. Ο δείκτης δε της διαμέτρου του ελύτρου προς την εγκάρσια διάμετρο του …
-
Η θέση της υπερηχογραφίας στην νευροπαρακολούθηση (neuromonitoring) των ασθενών με κρανιοεγκεφαλική κάκωση
… practice. The optic nerve sheath diameter (ONSD) has been reported to be increased in patients with intracranial hypertension. Direct measurement of the ONSD is possible by means of optic nerve sonography. Brain death (BD) is defined as the irreversible cessation of all hemispheric, …
-
Coded Hemodynamic Imaging of the Jugular Vein and Ultrasound Imaging of the Optic Nerve Sheath Diameter during Manipulations of Intracranial Pressure by Head-Down Tilt
… by nICP-TCD and optic nerve sheath diameter (ONSD). Linear mixed models were used to determine how IJV CSA, IJV blood flow, nICP-TCD and ONSD changed with HDT and over time. Repeated measures correlation was used to test the associations between IJV CSA, IJV blood flow, nICP-TCD, and ONSD. …
-
Η συμβολή του διακρανιακού doppler υπερηχογραφήματος στη διάγνωση του εγκεφαλικού θανάτου
… ICP monitoring. The optic nerve sheathdiameter (ONSD) has been reported to be increased in patients with intracranialhypertension. Direct measurement of the ONSD is possible by means of optic nervesonography. Accordingly, TCCD derived indices such as the pulsatility index (PI) andDoppler …
-
Improving Diagnosis and Understanding the Pathophysiology of Tuberculous Meningitis
… higher baseline optic nerve sheath diameter (ONSD) associated with more severe TBM and abnormal brain imaging (abnormal imaging 0.55cm vs. normal imaging 0.50cm, p=0.01). Baseline ONSD was higher in participants who died by 3 months (0.56cm [15/72]) vs. participants who survived (0.52cm …
-
Επεμβατική και υπερηχοτομογραφική μελέτη της ενδοκράνιας πίεσης σε πειραματικό ζωικό μοντέλο ενδοκράνιας υπέρτασης
… (TCCD), optic nerve sheath diameter, ONSD) and Pupil Constriction Velocity (PCV) after a pupillary light reflex (PLR). In this way, we tried to conclude to statistically significant data that will strengthen the usefulness of non-invasive ICP monitoring methods in clinical practice, in …
-
Η χρήση του παρακλίνιου υπερήχου στην επείγουσα προνοσοκομειακή ιατρική: Αξιολόγηση βαρέως πάσχοντος ασθενούς και θεραπευτικοί χειρισμοί
… καρδιολογική εκτίμηση, CASA/PAUSE για ανακοπή, ONSD για ενδοκράνια πίεση) αξιοποιούνται αποτελεσματικά από εκπαιδευμένους ιατρούς και διασώστες, ενώ η τηλε‑υπερηχογραφία ενισχύει την εφαρμογή σε απομακρυσμένα ή δυσπρόσιτα περιβάλλοντα, όπως καταστροφές, εμπόλεμες ζώνες και ανθρωπιστικές …
-
Evaluating Factors That Influence Optic Nerve Head Morphology
… OCT scans, IOP, and optic nerve sheath diameter (ONSD, a surrogate measure for ICP) were acquired over a 12-hour period in both seated (n = 30) and 6-degree head-down tilt (HDT, n = 10) positions. Changes in ONH morphology were assessed and compared between postures. (2) In 8 healthy non-human …
-
Evaluation of the effects of general anesthesia on the ultrasonographic optic nerve sheath diameter of dogs
The objectives of this study were to investigate the effects of anesthesia on the ultrasonographic optic nerve sheath diameter of dogs. Dogs without signs of elevated intracranial pressure, glaucoma or optic nerve disease were anesthetized and optic nerve sheath diameter was recorded at three time …