Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"OSB sheathing"”.

  1. Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing

    … strand board is a common material for shear wall sheathing. an OSB is made by using wood chips as raw materials that undergo high temperature pressing to create a multi-larger structure material. Due to the OSB having a high strength in shear, it is an important material used in the construction …

    unt Repository record for Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing (opens in a new tab)

  2. Investigation of Shear Capacity for Light-Frame Wood Walls Constructed with Insulated Oriented Strand Board Panels

    … members and exterior oriented strand board (OSB) sheathing. Placing this insulation layer between the framing members and exterior sheathing reduces the capacity of a wood shear wall to resist lateral loading. The objectives of this research were to identify the behavior of walls constructed …

    clemson Repository record for Investigation of Shear Capacity for Light-Frame Wood Walls Constructed with Insulated Oriented Strand Board Panels (opens in a new tab)

  3. Lateral resistance of new mid-ply shear wall (MPSW2) connections – performance of different materials

    … was dominated by dowel bearing failures of the OSB sheathing and not the classical nail withdrawal failures observed in traditional light wood frame shear walls. The load-slip data was fitted to load-slip equations (Foschi, 1974) and a mechanic-based load-slip model, HYST algorithm (Foschi, …

    ubc Repository record for Lateral resistance of new mid-ply shear wall (MPSW2) connections – performance of different materials (opens in a new tab) Download PDF for Lateral resistance of new mid-ply shear wall (MPSW2) connections – performance of different materials (opens in a new tab)

  4. Effects of ground motion duration on the seismic performance and collapse capacity of timber structures

    … structure with engineered oriented strand board (OSB) sheathing and stucco was 26%, for the same structure but without stucco was 29%, and for structure with horizontal board sheathings was 61%, respectively. The reduction in median collapse capacity for the mid-rise woodframe structure was 18%. …

    ubc Repository record for Effects of ground motion duration on the seismic performance and collapse capacity of timber structures (opens in a new tab) Download PDF for Effects of ground motion duration on the seismic performance and collapse capacity of timber structures (opens in a new tab)

  5. Modeling the behavior of wood-based composite sheathing under hygrothermal load

    … models were experimentally validated for OSB and plywood sheathing. Test variables included the panel type, exposure (symmetric and non-symmetric MC gradient) and specimen configuration (single span, multiple span). The comparison of measured and predicted deflections are presented. The …

    vt Repository record for Modeling the behavior of wood-based composite sheathing under hygrothermal load (opens in a new tab)

  6. The Racking Performance of Light-Frame Shear Walls

    … a horizontal position with oriented strandboard (OSB) sheathing on one side. To obtain conservative estimates, no dead load was applied in the wall plane during the tests. The nail-edge distance across the top and bottom plates varied from 10 mm (3/8 in.) to 19 mm (3/4 in.). Twelve walls were …

    vt Repository record for The Racking Performance of Light-Frame Shear Walls (opens in a new tab)

  7. Performance and Design Approaches for Perforated Light-frame Wood Shear Walls

    … walls tested were constructed with 2x4 studs and OSB sheathing using either the SSW, PSW, or FTAO design method. Three of the wall specimens were tested at SDSU. In-plane loading was applied to each specimen via a hydraulic actuator attached to one end of the wall top plate. All of the walls were …

    sdstate Repository record for Performance and Design Approaches for Perforated Light-frame Wood Shear Walls (opens in a new tab)

  8. Hygrothermal performance of different wood-frame wall assemblies wetted by simulated rain infiltration

    … into the stud cavity behind the exterior sheathing, i.e. the back wall. Once rainwater migrates into the stud space, it cannot easily evacuate and is thus likely to accumulate, leading to potential degradation of the wood studs and exterior sheathing, depending on the temperature …

    concordia Download PDF for Hygrothermal performance of different wood-frame wall assemblies wetted by simulated rain infiltration (opens in a new tab)

  9. Numerical study of the structural performance of strong wood light-frame shear walls under large lateral loads

    … typically comprised of timber framing members, sheathing panels such as plywood or oriented strand board (OSB), and fasteners like nails and bolts. The best performance of such walls is achieved when most of the energy is dissipated through shear deformation in the sheathing-to-framing …

    uvic Repository record for Numerical study of the structural performance of strong wood light-frame shear walls under large lateral loads (opens in a new tab)

  10. Corrugated wood composite panels for structural decking

    … The composite deck system, which consisted of an OSB sheathing (15/32” thick) nailed-glued (using 3d ringshank nails and AFG-01 subfloor adhesive) to the corrugated subfloor achieved about 60% of the full composite stiffness resulting in about 3 times the bending stiffness of the corrugated …

    mtu Repository record for Corrugated wood composite panels for structural decking (opens in a new tab)