Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 45 for “"OSEM"”.

  1. OSEM : occupant-specific energy monitoring.

    … energy-usage feedback is essential. The OSEM (Occupant-Specific Energy Monitoring) system presented in this work is capable of monitoring individualized energy usage. OSEM system uses the electromagnetic field (EMF) radiated by appliances as a signature for appliance identification. An …

    louisville Repository record for OSEM : occupant-specific energy monitoring. (opens in a new tab)

  2. Validation of OSEM algorithm for attenuation correction in cardiac SPECT studies

    … optional hardware (CT imaging) and software (OSEM reconstruction algorithm) technology attempting to produce attenuation corrected (artefacts-free) images and more accurate quantitative cardiac SPECT studies. However, this attenuation correction (AC) technique has not received widespread …

    whiterose Download PDF for Validation of OSEM algorithm for attenuation correction in cardiac SPECT studies (opens in a new tab)

  3. Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction

    … of stopping rule methods for the MLEM and OSEM algorithms used in image reconstruction positron emission tomography (PET). The development of the stopping rules is based on the study of the properties of both algorithms. Analyzing their mathematical expressions, it can be observed that the …

    greece Repository record for Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction (opens in a new tab)

  4. Development and validation of the quantitation of S.P.E.C.T. images for clinical applications

    … (2) ordered-subset expectation maximization (OSEM), (3) OSEM plus attenuation correction (AC), (4) OSEM plus detector response compensation (DRC), (5) OSEM plus AC and DRC, and (6) OSEM plus AC, DRC and scatter correction (SC). iQuant software was developed to affectively evaluate the …

    ubc Repository record for Development and validation of the quantitation of S.P.E.C.T. images for clinical applications (opens in a new tab) Download PDF for Development and validation of the quantitation of S.P.E.C.T. images for clinical applications (opens in a new tab)

  5. Anatomically informed image reconstruction for time of flight positron emission tomography

    … (ordered subsets expectation maximisation (OSEM)) and advanced iterative algorithms (TOF-OSEM and TOF-kernelised expectation maximisation (TOF-KEM)). TOF-PET improves conventional PET imaging as it localises the event along the line of response (LOR) within a small region with an uncertainty …

    whiterose Download PDF for Anatomically informed image reconstruction for time of flight positron emission tomography (opens in a new tab)

  6. Accelerated Monte Carlo Based Simultaneous Dual-isotope SPECT Reconstruction

    … ordered subset expectation maximization (OSEM) alogrithm, named as simultaneous ordered subset-expectation maximization (Sim-OSEM), to perform this step. We have undertaken a number of simulation tests and phantom studies to verify this approach in case of both of the dual-isotope …

    mcmaster Repository record for Accelerated Monte Carlo Based Simultaneous Dual-isotope SPECT Reconstruction (opens in a new tab)

  7. Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography

    … the ordered subset expectation maximisation (OSEM) algorithm. Dedicated point spread function (OSEM+PSF) and the background correction (OSEM+PSF+BC) were incorporated into the reconstruction for spill in correction. For region of interest (ROI) analysis, a semi-automated ellipsoidal ROIs were …

    whiterose Download PDF for Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography (opens in a new tab)

  8. Image quality and quantitation accuracy of penalized-likelihood reconstruction method for ¹⁸F and ⁹⁰Y

    … Ordered Subset Expectation Maximization (OSEM), the standard image reconstruction algorithm in the clinic, creates mottled images making small lesion detection for ¹⁸F and ⁹⁰Y PET imaging difficult. The penalized-likelihood (PL) reconstruction technique with a relative difference penalty …

    ubc Repository record for Image quality and quantitation accuracy of penalized-likelihood reconstruction method for ¹⁸F and ⁹⁰Y (opens in a new tab) Download PDF for Image quality and quantitation accuracy of penalized-likelihood reconstruction method for ¹⁸F and ⁹⁰Y (opens in a new tab)

  9. Dětská léčebna se speleoterapií Ostrov u Macochy

    … radí stavbu do triedy energeticky úsporných. Osem objektov prepojených s masívnou kolonádou v strednej ose svojou dispozíciou núti užívateľa využiť energetické výhody.

    brno-tech Repository record for Dětská léčebna se speleoterapií Ostrov u Macochy (opens in a new tab)

  10. Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography

    … full 3D reconstructions: FORE + 2D FBP, FORE + OSEM and FORE + SAGE. The phantom figures of merit that are used to evaluate these new algorithms are: resolution, noise, contrast recovery, signal-to-noise ratio, image uniformity and time activity curve variability. Using patient scans, the images …

    ubc Repository record for Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography (opens in a new tab) Download PDF for Evaluation of new iterative and rebinning reconstruction algorithms in fully three-dimensional positron emission tomography (opens in a new tab)

  11. Quantitative SPECT Image Reconstruction using an Accelerated Monte Carlo based Maximum A-Posteriori (MAP) Algorithm

    … ordered subset-expectation maximization (Sim-OSEM), to perform this step. In this study, we have undertaken a number of simulation tests and phantom studies to verify this approach. The proposed reconstruction technique was also evaluated by reconstruction of experimentally acquired phantom …

    mcmaster Repository record for Quantitative SPECT Image Reconstruction using an Accelerated Monte Carlo based Maximum A-Posteriori (MAP) Algorithm (opens in a new tab)

  12. Aplikace kondenzátorového svařování a hodnocení svarů

    … a hodnotenie vzoriek. Vypracovaných bolo celkom osem vzoriek, po dvoch druhoch v kombinácii uhlíková-uhlíková a austenitická (korozivzdorná) - uhlíková oceľ bolo pripravených pomocou zvárania. Pre všetky experimentálne prevedené spoje bol pripravený metalografický výbrus a bola hodnotená …

    brno-tech Repository record for Aplikace kondenzátorového svařování a hodnocení svarů (opens in a new tab)

  13. Napájecí zdroj pro opravu grafických karet

    … Navrhovaný externý regulátor je ovládaný osem fázovým integrovaným kontrolérom, ktorý snímaním napätia a prúdu každej fázy, balansuje ich zaťaženie a poskytuje ochranu proti nadprúdu a skratu.

    brno-tech Repository record for Napájecí zdroj pro opravu grafických karet (opens in a new tab)

  14. Rozpoznání významných prvků v textu webových stránek

    … výskytmi názvov. Bolo natrénovaných celkom osem modelov v českom jazyku pre rozpoznanie názvov produktov a kníh použitím knižnice spaCy. Výsledné modely dosahujú f-score až 89.94 pre triedu produktov a 84.26 pre triedu kníh na vlastnej testovacej dátovej sade.

    brno-tech Repository record for Rozpoznání významných prvků v textu webových stránek (opens in a new tab)

  15. Zdroje cen pro porovnávací způsob ocenění u rodinných domů v severní části okresu Brno-venkov

    … v severní části okresu Brno–venkov je vytvoriť osem databáz rodinných domov na základe ceny inzerovanej a následne ceny realizovanej. Pomocou vstupnej databázy sú vytvorené jednotlivé databázy pre ocenenie. Cieľom je následné porovnanie databáz s realizovanou cenou a inzerovanou cenou a ich …

    brno-tech Repository record for Zdroje cen pro porovnávací způsob ocenění u rodinných domů v severní části okresu Brno-venkov (opens in a new tab)

  16. Webový portál pro fotbalové fanoušky

    … a použité pri klasifikácii. Bolo preskúmaných osem rôznych klasifikačných algoritmov, pričom algoritmus logistickej regresie dosiahol najlepšie výsledky v oboch ligách. V prípade Premier League dosiahol model na testovacej sade presnosť 55%. V porovnaní s predpoveďami stávkových kancelárií bola …

    brno-tech Repository record for Webový portál pro fotbalové fanoušky (opens in a new tab)

  17. Development of a novel method to estimate kinetic micro-parameters in dynamic whole-body PET imaging protocols

    … of the ordered-subset expectation maximization (OSEM) reconstruction algorithm on the tradeoff curves. In addition, for overall visibility, which is a measure of the capability of identifying suspicious lesions in WB (i.e., global inspection), the overall signal-to-noise ratio (SNR) and spatial …

    ubc Repository record for Development of a novel method to estimate kinetic micro-parameters in dynamic whole-body PET imaging protocols (opens in a new tab) Download PDF for Development of a novel method to estimate kinetic micro-parameters in dynamic whole-body PET imaging protocols (opens in a new tab)

  18. Investigation of problems created in SPECT images by artifacts in the attenuation map and correction methods

    … presents three map reconstruction methods: FBP, OSEM and OSTGS. OSTGS has been tested by using computer simulations described in Chapter 3. Chapter 3 presents transmission simulations performed analytically. The analytical transmission simulations can be used to simulate simultaneous transmission …

    ubc Repository record for Investigation of problems created in SPECT images by artifacts in the attenuation map and correction methods (opens in a new tab) Download PDF for Investigation of problems created in SPECT images by artifacts in the attenuation map and correction methods (opens in a new tab)

  19. Fourier regularization applied to spect reconstruction

    … (FBP), Ordered Subset Expectation Maximization (OSEM), and two variations of FRECT. The sensitivity with respect to experimental noise in the data is found empirically for all reconstruction methods, and analytically for those methods that allow such analysis.

    ubc Repository record for Fourier regularization applied to spect reconstruction (opens in a new tab) Download PDF for Fourier regularization applied to spect reconstruction (opens in a new tab)

  20. Analýza obsazenosti parkoviště ze obrazu a zpracování získaných dat

    … výrezov zo sémantických máp. Práca obsahuje osem experimentov, ktoré podrobne analyzujú dané režimy, s informáciou o trénovacích parametroch v podobe tabuľky, po ktorej nasleduje vyhodnotenie výsledkov daného experimentu. Najlepší model pre datasety PKLot a CNRPark-EXT dosiahol presnosť …

    brno-tech Repository record for Analýza obsazenosti parkoviště ze obrazu a zpracování získaných dat (opens in a new tab)

Page 1 of 3