Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"OSLD"”.

  1. Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld

    … and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the …

    uthsc Repository record for Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld (opens in a new tab)

  2. Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms

    … to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a …

    uthsc Repository record for Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms (opens in a new tab)

  3. Creating optically stimulated luminescence 3D printing filament and synthesizing radiosensitive optically stimulate luminescence crystals

    … accurately. Optically stimulated dosimeters (OSLD) are passive dosimeters that collect dosimetric information and are read later by using a stimulating laser to stimulate luminescence from the dosimeter, while a photomultiplier tube (PMT) measures the intensity of the luminescing light. We …

    colostate Repository record for Creating optically stimulated luminescence 3D printing filament and synthesizing radiosensitive optically stimulate luminescence crystals (opens in a new tab)

  4. Characterization of Oslds For Use In Small Field Photon Beam Dosimetry

    … optically stimulated luminescence dosimeters (OSLDs) whose visible active luminescent area has been masked. The phantom has two measurement points with two OSLDs at each location and a film insert for localization purposes only. The masked OSLDs were characterized accounting for various …

    uthsc Repository record for Characterization of Oslds For Use In Small Field Photon Beam Dosimetry (opens in a new tab)

  5. Safety and Accuracy of Employing Active Breathing Coordinator (ABC) Based Deep Inspiration Breath Hold (DIBH) Technique in Delivery of Radiation Therapy for Locally Advanced Left Sided Breast Cancer

    … Optically stimulated luminescent dosimeter (OSLD) readings were taken at 1 cm above, below, and at the junction on at least 3 different fractions from 10 patients to determine accuracy of treatment dose. Acute and delayed skin toxicities, as defined by the common terminology criteria for …

    utswmed Repository record for Safety and Accuracy of Employing Active Breathing Coordinator (ABC) Based Deep Inspiration Breath Hold (DIBH) Technique in Delivery of Radiation Therapy for Locally Advanced Left Sided Breast Cancer (opens in a new tab)

  6. Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode

    … optically stimulated luminescence dosimeters (OSLD) used for dosimetric measurements. OSLD doses were compared to those calculated by Eclipse Treatment Planning System. The plans were delivered to vials of cells to confirm whether dose to a moving target is compromised, changing cell survival. …

    ubc Repository record for Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode (opens in a new tab) Download PDF for Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode (opens in a new tab)

  7. In Vivo δοσιμετρία με χρήση δοσιμέτρων φωτοφωταύγειας (OSLs) σε εφαρμογές ακτινοθεραπείας καρκίνου μαστού

    … τα TLD . Μέθοδος: Χρησιμοποιήθηκαν τα δοσίμετρα OSLDs (Nanodot dosimeters - Al2O3: C, Landauer, Inc., Glenwood, IL), τα οποία είναι λεπτοί δίσκοι διαμέτρου 4 mm και πάχους 0,3 mm 0,3 mm που βρίσκονται εγκλεισμένοι σε πλαστική θήκη διαστάσεων 10 × 10 × 2 mm καθώς και αντίστοιχα χρησιμοποιήθηκαν …

    athens Repository record for In Vivo δοσιμετρία με χρήση δοσιμέτρων φωτοφωταύγειας (OSLs) σε εφαρμογές ακτινοθεραπείας καρκίνου μαστού (opens in a new tab)

  8. Development of A Remote Dosimetric Audit Framework For Carbon Therapy

    … and optically-stimulated luminescent dosimeters (OSLD) and GafChromic film. The aim of this work will be to characterize dosimeters and materials for use in carbon radiotherapy and combine these tools to create an end-to-end anthropomorphic phantom audit. The absorbed dose corrections factors for …

    uthsc Repository record for Development of A Remote Dosimetric Audit Framework For Carbon Therapy (opens in a new tab)

  9. Measuring terrestrial wildlife external radiation exposure under field conditions

    … to identify four passive dosimeters (i.e. TLD, OSLD, RPLD and DIS), which should be suitable for reindeer. To protect these dosimeters during use, they were housed in an aluminium box that could be attached to a collar around the reindeer’s neck. The performance of dosimeters within the box was …

    salford Download PDF for Measuring terrestrial wildlife external radiation exposure under field conditions (opens in a new tab)

  10. Refining eye-lens dosimetry using optically stimulated luminescent dosimeters under updated regulatory dose limits

    … optically stimulated luminescence Dosimeters (OSLDs) for occupational eye-lens dosimetry under updated dose limits. In Canada, Thermoluminescent Dosimeters remain commonly used for eye-lens monitoring, but their heat-based readout erases stored dose information, resulting in the inability to …

    uoit Repository record for Refining eye-lens dosimetry using optically stimulated luminescent dosimeters under updated regulatory dose limits (opens in a new tab)

  11. Optically Stimulated Luminescence Dosimetry in Permanent Breast Seed Implant Brachytherapy: a Monte Carlo Approach

    … in optically stimulated luminescence dosimeters (OSLDs). These were supplemented by a procedure to calibrate OSLDs to a Pd-103 source and experimentally derived OSLD calibration factors. These results enable in-vivo dosimetry of a PBSI patient's skin dose following treatment via OSLDs placed on …

    calgary Repository record for Optically Stimulated Luminescence Dosimetry in Permanent Breast Seed Implant Brachytherapy: a Monte Carlo Approach (opens in a new tab)

  12. Μελέτη γωνιακής εξάρτησης δοσιμέτρων οπτικής φωταύγειας σε 1.5Τ μαγνητικό πεδίο

    … Τα δοσίμετρα διεγερμένης οπτικής φωταύγειας (OSLD) έχουν αποκτήσει μεγάλη δημοτικότητα ως δοσίμετρα έμμεσης ανάγνωσης με πολλές εφαρμογές στην Ιατρική Φυσική. Το εμπορικά διαθέσιμο OSLD είναι το σύστημα nanoDot της Landauer, Inc. Ο ευαίσθητος όγκος του έχει το σχήμα ενός δίσκου από οξείδιο του …

    athens Repository record for Μελέτη γωνιακής εξάρτησης δοσιμέτρων οπτικής φωταύγειας σε 1.5Τ μαγνητικό πεδίο (opens in a new tab)

  13. Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston

    … Optically Stimulated Luminescent Dosimeters (OSLDs) are a prominent form of in-vivo dosimeter used both in clinics as well as for the audits of radiologicalequipment at the Imaging and Radiation Oncology Core (IROC)-Houston. Thesedosimeters have a recommended dose limit of 10 Gy due to a …

    uthsc Repository record for Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston (opens in a new tab)

  14. Determining The Viability Of A Novel OSL Film Dosimeter For In Vivo Dosimetry

    … Optically Stimulated Luminescent Dosimeter (OSLD) which was 3.5% difference. Conclusion: The early stages of OSL film trials show promise in the future, but work needs to be done to make the accuracy and reproducibility better for clinical use. The issues that arose in the in vivo tests are …

    vcu Repository record for Determining The Viability Of A Novel OSL Film Dosimeter For In Vivo Dosimetry (opens in a new tab)

  15. Χαρακτηρισμός δοσιμέτρων nanoDot οπτικής φωταύγειας (optically stimulated luminescent dosimeters - OSLDs) για in-vivo δοσιμετρία στην ακτινοθεραπεία

    … περιγράφουμε την δοσιμετρία οπτικής φωταύγειας (OSLD) και τα χαρακτηριστικά των δοσιμέτρων nanoDot. Αναλύουμε την αρχή λειτουργίας τους, τους παράγοντες που επηρεάζουν την απόκρισή τους, καθώς επίσης και τον τρόπο με τον οποίο μετράται το σήμα τους. Τα δοσίμετρα nanoDot είναι πολύ μικρά σε …

    athens Repository record for Χαρακτηρισμός δοσιμέτρων nanoDot οπτικής φωταύγειας (optically stimulated luminescent dosimeters - OSLDs) για in-vivo δοσιμετρία στην ακτινοθεραπεία (opens in a new tab)

  16. Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry

    This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters …

    uthsc Repository record for Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry (opens in a new tab)

  17. Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms

    … of optically stimulated luminescent detectors (OSLDs) in protons, allowing comparison to thermoluminescent detectors, and to be implemented into the Radiological Physics Center’s (RPC) remote audit quality assurance program for protons, and for remote anthropomorphic phantom irradiations. The …

    uthsc Repository record for Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms (opens in a new tab)