Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Off-axis Loading"”.

  1. Modelling & Experimental Investigations Of Distal Radius Surface Strain Distributions During Off-Axis Loading

    … of the most common types of fractures to occur. Loading is generally assumed to be purely axial, with forces aligned with the length of the distal radius when simulating a fall onto the outstretched hand. However, the mechanics of distal radius fractures are not well understood and contributions …

    sask Repository record for Modelling & Experimental Investigations Of Distal Radius Surface Strain Distributions During Off-Axis Loading (opens in a new tab)

  2. DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

    … out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field …

    maryland Repository record for DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES (opens in a new tab)

  3. The Effects of Off-Axis Loading on Fracture Risk in the Human Tibia

    … load is applied in line with the leg’s long axis, leaving non-standard postures largely uninvestigated. The purpose of this work was to study the effects of non-standard postures on the tibia’s injury tolerance. A pneumatic system was designed to facilitate impact testing. This system allows …

    mcmaster Repository record for The Effects of Off-Axis Loading on Fracture Risk in the Human Tibia (opens in a new tab)

  4. Off Axis Compressive Response of Ice-Templated Ceramics

    The off-axis compressive behavior of ice-templated ceramic was analyzed using experimental results and micro-mechanical model simulation. Ice-templated ceramics is a versatile processing technique used to manufacture anisotropic ceramic foam by exploiting the anisotropic growth characteristics and …

    odu Repository record for Off Axis Compressive Response of Ice-Templated Ceramics (opens in a new tab)

  5. Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling

    … determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an outstretched hand. The objective of this research was to identify moment arms in a HR-pQCT distal radius FE model that best predicted off-axis experimental failure load …

    sask Repository record for Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling (opens in a new tab)

  6. Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling

    … determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an outstretched hand. The objective of this research was to identify moment arms in a HR-pQCT distal radius FE model that best predicted off-axis experimental failure load …

    sask Repository record for Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling (opens in a new tab)

  7. Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study

    … implants under standardized cyclic and static off-axis loading conditions. Materials and Methods: Ten Straumann BLC implants were divided into two groups (n = 5): Group 1 received Locator® abutments and Group 2 received Novaloc® abutments. All abutments were tightened to 35 N·cm and retightened …

    wvu Repository record for Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study (opens in a new tab)

  8. Creep of plain weave polymer matrix composites

    … creep of plain weave composites under varying loading orientation and service conditions. Plain weave epoxy (F263)/ carbon fiber (T300) composite, currently used in aerospace applications, was procured as fabrics from Hexcel Corporation. Creep tests were conducted under two loading conditions: …

    manitoba Repository record for Creep of plain weave polymer matrix composites (opens in a new tab)

  9. Mechanical evaluation of pedicle screw fixation of the lumbar spine

    … of flexion-compression and forty-five degree off-axis flexion-compression The effect on stiffness of the loosening of device members was also studied. Testing was done in load control using an electrohvdrualic testing machine. UHMWPe blocks are used to simulate the vertebra. Assuming that …

    njit Repository record for Mechanical evaluation of pedicle screw fixation of the lumbar spine (opens in a new tab)

  10. Physically-based meso-scale modelling of unidirectional CFRPs for impact loading applications

    … the rate-dependency and pressure or multiaxial loading effects on the behaviour of UD CFRPs, which are crucial for applications where composite structures may be subjected to dynamic loading, are still not fully understood.</p> <p>The present work aimed to investigate some of these aspects and …

    oxford Repository record for Physically-based meso-scale modelling of unidirectional CFRPs for impact loading applications (opens in a new tab)

  11. Design, Development, and Testing of a Miniature Fixture for Uniaxial Compression of Ceramics Coupled with In-Situ Raman Spectrometer

    … loads up to 14,137 N, with negligible off axis loading, achieving target stresses of 500 MPa for samples of up to 6.00 mm in diameter. The system will be used in the future to study the structural changes in ceramics and ceramic composites, as well as to study thermal residual stress …

    ucf Repository record for Design, Development, and Testing of a Miniature Fixture for Uniaxial Compression of Ceramics Coupled with In-Situ Raman Spectrometer (opens in a new tab)

  12. Modeling the Stimulation of Vestibular Hair Cell Bundles Using Computational Fluid Dynamics and Finite Element Analysis

    … for free-standing bundles), and combined loading (physiologic for bundles with tip attachments) conditions to determine how the bundles behaved in each case. The bundles differed in the heights of their components, their length and width, and their number of steriocilia. Tip links were …

    vt Repository record for Modeling the Stimulation of Vestibular Hair Cell Bundles Using Computational Fluid Dynamics and Finite Element Analysis (opens in a new tab)

  13. Análise de critérios de falha em lâmina reforçada com tecido híbrido de fibra de vidro e carbono

    … from these tests that materials with fibers at off-axis loading angles exhibit lower strength, although they exhibit greater elongations when compared to samples with fibers aligned in the main direction of loading. Experimental data on shear properties, standardized by ASTM D3518M-13 (tensile …

    brazil-ufrn Repository record for Análise de critérios de falha em lâmina reforçada com tecido híbrido de fibra de vidro e carbono (opens in a new tab)

  14. Development of a novel endoprosthesis for canine limb-sparing using a finite element approach

    … radial screws and the distal metacarpal screws. Off-axis loading of the construct was also eliminated. The final design was approved for prototype development, biomechanical testing and cadaveric evaluation.

    colostate Repository record for Development of a novel endoprosthesis for canine limb-sparing using a finite element approach (opens in a new tab)

  15. A Passive Pure Moment Protocol for Testing Spine Segments: Development and Application

    … enough to accurately calculate the instantaneous axis of rotation (IAR) for a segment throughout a bending motion. The purpose of this study was to simulate a pure moment protocol using a programmable spine robot, and use the data gathered to calculate the IAR for harvested specimen and those …

    tenn-hsc Repository record for A Passive Pure Moment Protocol for Testing Spine Segments: Development and Application (opens in a new tab)

  16. Characterisation of environmentally friendly fibres for composites

    … fibre-polyester composites over a range of off-axis loading angles. The results were input into a number of micromechanical and semi-empirical models. It was found that the investigated fibres were highly anisotropic with the fibres longitudinal modulus being greater than the fibres …

    strathclyde Repository record for Characterisation of environmentally friendly fibres for composites (opens in a new tab)

  17. Defining the Role of Elastic Fibers in Tendon Mechanics

    … and the lungs that experience constant cyclic loading. In tendon, elastin only makes up 1-2% of the tissue by dry weight, yet prior work has demonstrated a significant impact of elastin on tendon mechanics despite its low content. Moreover, this work is motivated clinically by elastinopathic …

    wustl Repository record for Defining the Role of Elastic Fibers in Tendon Mechanics (opens in a new tab)

  18. Considerations for the Design of a UD-NCF Composite Energy Absorbing Structure for Frontal and Oblique Crush Loading

    … predicting their response under impact loading. However, CFRP components manufactured via high-pressure resin transfer (HP-RTM) with highly reactive resins enable reduced production cycle times and, thus, adoption in automotive structures. Unidirectional non-crimp fabric (UD-NCF) …

    waterloo Repository record for Considerations for the Design of a UD-NCF Composite Energy Absorbing Structure for Frontal and Oblique Crush Loading (opens in a new tab)