Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 17 of 17 for “"On-line coupling"”
-
On-line coupling of volcanic ash and aerosols transport with global and regional meteorological models
Explosive volcanic eruptions can eject large quantities of particulate matter that, along with other aerosol droplets and trace gases, are carried upwards into the atmosphere by the buoyant eruption column and then dispersed by winds aloft. The presence in the atmosphere of volcanic ash is a …
-
On-line coupling of capillary electrophoresis and liquid chromatography with electrospray ionization mass spectrometry for protein characterization
<p>On-line coupling of capillary isoelectric focusing (CIEF) and liquid chromatography (LC) with electrospray ionization mass spectrometry (ESIMS) is utilized for protein characterization;A microdialysis junction, based on a microdialysis membrane connecting both a separation capillary and a short, …
-
Enhanced NMR Detection of Mass -Limited Samples With Microcoil Probes: Increasing Sample Throughput and Improved on-Line Coupling to Microscale Separations
… by any other method, nuclear magnetic resonance (NMR) spectroscopy stands as an integral component of the modern academic and industrial chemical laboratory. The development of microcoils enables NMR analysis of small-volume, mass-limited samples. With their diminutive size, multiple …
-
New analytical strategies based on mass spectrometry for the sensitive analysis of protein and microRNA biomarkers in human biofluids
… the influence of the sample matrix components, and the limitations in sample volume. In this doctoral thesis, we present innovative strategies based on mass spectrometry (MS) for the separation, detection, characterization, and quantification of intact protein, enzymatically digested …
-
On Advances in Asymmetrical Flow Field Flow Fractionation for Biosample Characterization
Asymmetrical Flow Field Flow Fractionation is a technique with high versatility and is used for size fractionation of polydisperse and widely size distributed samples from various fields of research. Colloidal samples in food systems, formulated biologics from pharmaceutical science, nanoparticles …
-
On-line laser desorption/ionization mass spectrometry
Interfaces for on-line laser desorption/ionization mass spectrometry are presented in this dissertation. An on line laser desorption interface allows samples to be introduced directly into the mass spectrometer for high-throughput applications. For this research, a linear time of flight mass …
-
The Use of Microfluidics for Multiplexed Protein Analysis
… presented in this work explores the application of microfluidics to the field of proteomics through the design of a multi-channel microfluidic platform and the investigation of individual components of the system. The design of this microfluidic device allows the integration of several protein …
-
Supercritical Fluid Extraction Directly Coupled with Reversed Phase Liquid Chromatography for Quantitative Analysis of Analytes in Complex Matrices
… was to design a simple, novel interface for on-line coupling of Supercritical Fluid Extraction (SFE) with High Performance Reversed Phase Liquid Chromatography (HP-RPLC), and to explore its ability for quantitative analysis of analytes in different matrices. First, a simple interface was …
-
Coupled solid phase extraction-supercritical fluid extraction on-line gas chromatography of explosives from water
… has been developed for the quantitative extraction of nitrotoluenes (2,6-dinitrotoluene, 2,4-dinitrotoluene, and trinitrotoluene) from water. Three types of solid sorbents were investigated: two 47 mm Empore disks™ - octadecylsilane (C18) and styrene-divinylbenzene (SDVB); and one Bakerbond spe*™ …
-
Improving Off-line and On-line Supercritical Fluid Extraction Techniques by Elevating the Post-Restrictor Pressure
… problem with supercritical fluid extraction techniques. As a result of these high flow rates, solvent trapping is not efficient in many cases, and the more complicated sorbent trapping technique must be used. In addition, loss of the collection solvent may occur during the process making …
-
Laser desorption/ionization time-of-flight mass spectrometry of biomolecules
<p>Lasers have been used to generate ions for mass spectrometer detection. Laser energy can be efficiently and controllably transferred to the sample, because laser provides high energy with a short pulse (1 to 100 ns). Samples are vaporized and ionized before their decomposition. This technique is …
-
CE-microreactor-CE-MS-MS for protein analysis
… system that combines the speed and automation capabilities of CE with the detection and identification capabilities of MS. Integrating on-line enzymatic microreactor digestion with a CE-MS system reduces sample handling and allows fast digestions of small protein samples.In this thesis work, …
-
Ανάπτυξη αυτόματου χρωματογραφικού συστήματος ελέγχου υπολειμμάτων γεωργικών φαρμάκων και κύριων προϊόντων μετατροπής τους
… analytical method for the determination of a wide range of pesticides, major conversion products and other organic micropollutants (phenols, anilines and caffeine) in water based on the on-line coupling of solid phase extraction and high performance liquid chromatography (on-line …
-
Characterization of Proteins and Protein Complexes by Online Chromatographic Separations and Direct Infusion Native Mass Spectrometry
Because the functions of proteins and protein complexes are linked to their structures, structural characterization is important to understand the underlying function. Current structural biology techniques provide high-resolution structures, but have well-known challenges that limit the structural …
-
Evaluation of TH multi-scale coupling methods in BEPU analysis
… system with sub-channel codes (TH-TH coupling) in transient analysis provides an integrated tool with the capability of modelling in detail both the core thermal-hydraulic conditions and the system behaviour. Different code coupling methods are often used in the nuclear industry to …
-
Développement d’outils analytiques pour l’analyse de biomarqueurs de longue durée de vie de l’ypérite dans les échantillons biologiques
… adduits stables utilisés comme biomarqueurs de longue durée de vie et pouvant être détectés jusqu’à 120 jours dans l’organisme. Leur analyse est principalement réalisée par une procédure de séquençage qui cible uniquement les adduits formés avec les valines N-terminales de l’hémoglobine, …