Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 6 of 6 for “"Open phase faults."”
-
Investigation into open phase faults on transmission circuits.
Open phase faults are not commonly encountered on the South African power transmission systems. However, when these faults do occur it results in major power system interruptions and spurious tripping of healthy (circuits without faults) circuits to trip without giving any indication of the type or …
-
Fault tolerant control of a dual-three-phase electrical machine with predictive current control and reduced computation burden
… but an expensive solution. In conventional three-phase electrical drives, when an open or short circuit fault occurs on a phase of the machine, overall drive system is affected and operation of the machine becomes no longer possible. Therefore electrical machines with multiple phases or phase …
-
Synchrophasor Based Islanding & Open phase fault Protection in Distribution Systems
… shown in current research for anti-islanding and open-phase faults in the distribution feeder protection application, where the number of PMUs and performance required is somewhat lower than the bulk of power energy. Thus, the opportunity to invest in the implementation of synchronized measurement …
-
Developing fault-tolerant control strategies for a five-phase permanent-magnet machine drive system
Many critical five-phase permanent magnet synchronous machine (PMSM) drive systems require operation after either a single or dual open-phase fault occurs. Some of these drive systems use the open-end winding inverter topology as it allows for the injection of unbalanced phase currents, i.e. …
-
Control Strategies for Dual Inverter-fed Open-end Winding PM machines with Nonsinusoidal back EMFs
… benefits during a fault, PMSM drives with open-ended winding can be employed. Both ends of the windings in the prototype PMSM are connected to a dual inverter arrangement of two 2-level inverters both connected to one dc source. However, considering the zero sequence voltage is clamped to …
-
ANALYSIS AND CONTROL OF FIVE-PHASE PERMANENT MAGNET ASSISTED SYNCHRONOUS RELUCTANCE MOTOR DRIVE UNDER FAULTS
… advanced control methodologies for the five-phase permanent magnet assisted synchronous reluctance motor (F-PMa-SynRM) drive under various open phase fault conditions. F-PMa-SynRMs are principally reluctance-type machines which contain fewer magnets than permanent magnet machines. The major …