Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Open-Loop Response"”

  1. Aircraft-Pilot-Coupling: Parametric Study Using Multibody Dynamics Modelling of Pilot Biodynamics, Pilot Seat, and Inceptor

    … from the seat acceleration to the inceptor response. An optimizer is then used to obtain pilot joint stiffnesses and damping coefficients by matching the transfer functions to experimental data available in the open literature. The transfer functions are then integrated within a generic …

    carleton Repository record for Aircraft-Pilot-Coupling: Parametric Study Using Multibody Dynamics Modelling of Pilot Biodynamics, Pilot Seat, and Inceptor (opens in a new tab)

  2. Rolling-diaphragm hydrostatic transmission for the remote actuation of high-performance robots

    … technological paradigm. Shaping a suitable open-loop response, regardless the applied control, by embedding requirements of safety and performance in smart mechanical structures is the key principle that drove this study: lightweight design and backdrivability are considered as the ultimate …

    trento Repository record for Rolling-diaphragm hydrostatic transmission for the remote actuation of high-performance robots (opens in a new tab)

  3. A LabVIEW program to obtain the initiating component of a vergence eye movement in an open-loop experiment

    … The initiating component is described with open-loop control and the sustaining component is described as a closed-loop feedback control system. Previously, several languages have been utilized to develop programs to study and isolate the open-loop portion of vergence eye movements. …

    njit Repository record for A LabVIEW program to obtain the initiating component of a vergence eye movement in an open-loop experiment (opens in a new tab)

  4. The design and analysis of a discrete wide band power operational amplifier

    … along with a detailed analysis of the bias, open-loop response, closedloop response, and noise of the amplifier. The calculated variation of the bias currents was less than 1% per degree centigrate between zero and fifty degrees. The calculated equivalent input noise voltage was 3.19 …

    ut-knoxville Repository record for The design and analysis of a discrete wide band power operational amplifier (opens in a new tab)

  5. Analysis and control of thermoelastic vibrations in plate structures.

    … piezoelectric patches suitable for closed loop vibration control. The open loop response of this model subjected to a thermal shock is validated against the response of the Chapter 2 solution, and the closed loop response is validated against previous work. In both cases, the new finite …

    oklahoma-thes Repository record for Analysis and control of thermoelastic vibrations in plate structures. (opens in a new tab)

  6. Strain transducers for active control

    … in order to predict the sensor-actuator open loop response over much wider frequency range than is commonly used, so that the stability of the feedback control loop can be properly assessed using the Nyquist criterion. These simulations suggest that increasing the width and reducing the …

    soton Repository record for Strain transducers for active control (opens in a new tab)

  7. A Study of Stenosis and Insufficiency in the Mitral, Tricuspid and Aortic Heart Valves by Using Mathematical Modeling

    … contains no autoregulatory or neural control loops. Such simulations can not hope to duplicate the complex, integrated response of the cardiovascular system, but the "open loop" response may provide insight into the amount and type of "closed loop" control required for each type of simulation.

    marquette Repository record for A Study of Stenosis and Insufficiency in the Mitral, Tricuspid and Aortic Heart Valves by Using Mathematical Modeling (opens in a new tab)

  8. A New Self-Contained Electro-Hydraulic Brake System

    … of the cam as the optimization variable and the open-loop response time of the brake system as the objective function to be minimized. The solution to this problem is then obtained by the multi-layer design optimization process using the genetic algorithm (GA). Various control algorithms are …

    waterloo Repository record for A New Self-Contained Electro-Hydraulic Brake System (opens in a new tab)

  9. Estudo de estratégias de otimização para poços de petróleo com elevação por bombeio de cavidades progressivas

    … results was compared. The simulated and actual open loop response was compared to validate simulation. A case study was accomplished to validate equipment selection specialist system

    brazil-ufrn Repository record for Estudo de estratégias de otimização para poços de petróleo com elevação por bombeio de cavidades progressivas (opens in a new tab)

  10. Aerodynamic and Electromechanical Design, Modeling and Implementation Of Piezocomposite Airfoils

    … is presented. First, the electromechanical response of Macro-Fiber Composite based unimorph and bimorph structures is analyzed. A distributed parameter electromechanical model is presented for interdigitated piezocomposite unimorph actuators. Necessary structural features that result in …

    vt Repository record for Aerodynamic and Electromechanical Design, Modeling and Implementation Of Piezocomposite Airfoils (opens in a new tab)

  11. Switched Capacitor Circuit Based Isolated Power Converters

    … its effectiveness is showcased by comparing its open-loop response simulation results to those of a detailed circuit model. For better line disturbance rejection, a closed-loop voltage controller with feed-forward compensation is designed. Experiment results from the 1-kW prototype with digital …

    ohiolink Repository record for Switched Capacitor Circuit Based Isolated Power Converters (opens in a new tab)

  12. Tapped-Inductor Buck DC-DC Converter

    … were analytically defined. A controller closed-loop system is implemented. Various time and frequency domain parameters affecting the system response are measured and compared to the open-loop system.All the theoretically obtained responses are implemented using MATLAB and verified using saber …

    ohiolink Repository record for Tapped-Inductor Buck DC-DC Converter (opens in a new tab)