Showing 1 to 20 of 26 for “"Ophthalmic imaging"”.
-
Transillumination techniques in ophthalmic imaging
In vivo imaging of the human cornea and retina is typically performed in a reflection geometry. Images are formed from light that has backscattered off corneal microstructures or backreflected from the retina. In this configuration, artifacts caused by superficial surface reflections are often …
-
Development of Jones matrix tomography for functional ophthalmic imaging
… non-invasive, three-dimensional structure imaging. Since the introduction of OCT technique, OCT has shown its powerful utility especially in the field of ophthalmology. However its capability is still limited to the structural investigation. Because many eye diseases are tightly associated …
-
Self-Aligning and Handheld Optical Coherence Tomography for Ophthalmic Imaging
… in ophthalmology, bringing three-dimensional imaging of the human retina into the hands of a physician in the matter of seconds. Traditional OCT systems, however, are designed for patients who can readily cooperate with a tabletop device in the eye clinic. This excludes many populations with …
-
Spectral Domain Optical Coherence Tomography System Development for in Vivo Ophthalmic Imaging
… powerful new tool for noninvasive human retinal imaging. I have developed a low‐cost, high resolution real‐time Spectral Domain Optical Coherence Tomography (SDOCT) system optimized for rapid 3D imaging of the human retina in vivo. Then functional retinal OCT imaging such as polarization …
-
Development of Optical Coherence Tomography Systems for Ophthalmic Imaging and Intrasurgical Guidance
<p>Ophthalmic microsurgery is one of the most commonly performed surgical procedures in the world and it necessitates precise three-dimensional manipulation of tissue at sub-millimeter spatial scales. As a result, ophthalmic surgeons require an operating microscope to perform surgery and to asses …
-
Graph Theory and Dynamic Programming Framework for Automated Segmentation of Ophthalmic Imaging Biomarkers
… diseases. Earlier and faster detection of ophthalmic imaging biomarkers also leads to optimal treatment and improved vision recovery. While modern optical imaging technologies such as optical coherence tomography (OCT) and adaptive optics (AO) have facilitated in vivo visualization of the …
-
Development of Extended-Depth Swept Source Optical Coherence Tomography for Applications in Ophthalmic Imaging of the Anterior and Posterior Eye
… tomography (OCT) is a non-invasive optical imaging modality that provides micron-scale resolution of tissue micro-structure over depth ranges of several millimeters. This imaging technique has had a profound effect on the field of ophthalmology, wherein it has become the standard of care for …
-
Multimodal photoacoustic remote sensing (PARS) microscopy combined with swept-source optical coherence tomography (SS-OCT) for in-vivo, non-contact, functional and structural ophthalmic imaging applications
Ophthalmic imaging has long played an important role in the understanding, diagnosis, and treatment of a wide variety of ocular disorders. Currently, available clinical ophthalmic imaging instruments are primarily optical-based, including slit-lamp microscopy, fundus photography, confocal …
-
Development of Coherence-Gated and Resolution-Multiplexed Optical Imaging Systems
… techniques are particularly well-suited for imaging tissue morphology, biological dynamics, and disease pathogenesis by providing noninvasive access to subcellular-resolution diagnostic information. State-of-the-art spectral domain optical coherence tomography (SDOCT) systems provide …
-
Functional Spectral Domain Optical Coherence Tomography Imaging
… (SDOCT) is a high-speed, high resolution imaging modality capable of structural and functional resolution of tissue microstructure. SDOCT fills a niche between histology and ultrasound imaging, providing non-contact, non-invasive backscattering amplitude and phase from a sample. Due to the …
-
Parallel Processing For Adaptive Optics Optical Coherence Tomography (AO-OCT) Image Registration Using GPU
… (AO-OCT) is a high-speed, high-resolution ophthalmic imaging technique offering detailed 3D analysis of retina structure in vivo. However, AO-OCT volume images are sensitive to involuntary eye movements that occur even during steady fixation and include tremor, drifts, and micro-saccades. …
-
Automated Beam Stitching and Segmentation Procedure for Space Division Multiplexing Optical Coherence Tomography Angiography
… Tomography Angiography (OCTA) has revolutionized ophthalmic imaging and its capability to produce high-resolution 3D maps of the retinal microvasculature is instrumental in diagnosing retinovascular diseases such as diabetic retinopathy and age-related macular degeneration; However, the existing …
-
Prior knowledge-driven model pre-training and fine-tuning for ophthalmic image analysis
Deep learning has become a cornerstone in ophthalmic image analysis, enabling automated disease detection, grading, and segmentation across modalities such as fundus photography, OCT angiography (OCTA), and fundus fluorescein angiography (FFA). However, its deployment faces major challenges: …
-
Histopathology and Image Validation of Outer Retinal Tubulations in Age-Related Macular Degeneration
High-resolution imaging of the retina using spectral domain optical coherence tomography (SD-OCT) and adaptive optics scanning laser ophthalmoscopy (AOSLO) is revealing new information about photoreceptor degeneration in age-related macular degeneration (AMD) and other diseases impacting rod and …
-
Modeling and Control of a Magnetic Fluid Deformable Mirror for Ophthalmic Adaptive Optics Systems
… correctors, to improve the resolution of imaging systems by compensating for complex optical aberrations. Recently, magnetic fluid deformable mirrors (MFDM) were proposed as a novel type of wavefront correctors that offer cost and performance advantages over existing wavefront correctors. …
-
Deep Learning Image Analysis Framework for Clinical Management of Retinal and Corneal Diseases
… vision impairment. The advent of high‐resolution ophthalmic imaging technology enables the visualization of internal and external structures of the eye, thereby aiding clinicians in the assessment of these diseases. However, there are high costs and constraints associated with manual image …
-
A Comprehensive Framework for Adaptive Optics Scanning Light Ophthalmoscope Image Analysis
… in the eye. The development of adaptive optics ophthalmic imaging systems has made high resolution visualization of ocular microstructures possible. These systems include the confocal and split detector adaptive optics scanning light ophthalmoscope (AOSLO), which can visualize human cone and rod …
-
Enhancing the Visualization of the Peripheral Retina with Wide Field-of-View Optical Coherence Tomography
… narrow field-of-view, because three-dimensional imaging of the peripheral retina may prove to be important in the early detection of neurodegenerative diseases, such as Alzheimer's and dementia, and the monitoring of known ocular diseases, such as diabetic retinopathy, retinal vein occlusions, …
-
Η εφαρμογή των αποτελεσμάτων της ανάλυσης δεδομένων διαγνωστικών και θεραπευτικών προσεγγίσεων, σε ασθενείς με ραγοειδίτιδα σε ένα τριτοβάθμιο ακαδημαϊκό κέντρο αναφοράς, στην βελτίωση της αντιμετώπισης των ραγοειδιτίδων
… the diagnostic paracentesis), the progress of ophthalmic imaging and the collaboration with other specialties enabled clinicians to make faster and more accurate diagnosis in patients with uveitis. Modern treatments and surgical techniques played a critical role in the management of ocular …
Page 1 of 2