Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 101 for “"Optical Motion Capture"”.
-
Accessible and Automated Optical Motion Capture with Multimodal Data
… and virtual reality (VR) experiences. Realistic motions can be recorded through a process called motion capture (mocap). Optical marker-based mocap is considered the gold standard for human mocap. This method uses infrared cameras to record retro-reflective markers that are placed on the surface …
-
Camera-Based Home Rehabilitation Exercise Monitoring: A Technical Evaluation Against Optical Motion Capture
… recorded using an iPhone 13, while reference motion data were collected with a Qualisys optical motion capture system. MediaPipe Pose was used to extract body landmarks from the videos, and exercise-specific metrics were computed, including trunk orientation, normalized pelvis displacement, …
-
Designing a Tool for Assisting in the Setup of Optical Motion Capture Systems
As optical motion capture systems grow bigger and more complex, the need for mobility when interacting with these systems becomes apparent due to the increasing spatial distances between system components. Seeing how these technologies rapidly evolve and how their usage is becoming more common, …
-
Improved Accuracy in Optical Motion Capture Measurements Leads to Increased Sensitivity to Kinematic Changes
Clinical optical motion capture allows us to obtain kinematic and kinetic outcome measures that aid clinicians in diagnosing and treating different pathologies affecting healthy gait. The long term aim for gait centres is for subject-specific analyses that can predict, prevent, or reverse the …
-
The effect of multimodal data sources in parallel on the accuracy and reliability of optical motion capture of human subjects
Optical motion capture is a powerful tool for human motion analysis. However, an intrinsic limitation of this method is its dependence upon line of sight, which when occluded, prevents measurement of position, resulting in data loss and failure of trajectory tracking. The thesis aims to investigate …
-
An Integrationless Optimization Method for IMU-based Human Motion Measurement
… throughout the treatment process. While optical motion capture systems are currently the most commonly used technology for measuring human movement, they are expensive and require a well-controlled indoor test environment, necessitating repeated patient visits to the clinic. Wearable …
-
Classical ballet training for apparently healthy older adults : evaluation of biomechanical and functional outcomes
… strength, balance ability, and joint range of motion. Exercise interventions mitigate age-related decline in physical function but are seldom maintained long-term. A key barrier is lack of enjoyment. Dance-based interventions offer an enjoyable form of physical activity which may promote …
-
Validation and Use of Inertial Sensors to Assess Changes in Gait Stability Introduced by a Robot Companion
… aims to validate the use of an inertial sensor motion capture system for measuring gait stability of walking humans, and then to apply that system to examine how an accompanying robot affects human gait. First, we tracked walking participant motion using optical and inertial sensors and …
-
Capturing Human Hand Kinematics for Object Grasping and Manipulation
… data for individual fingers of a hand within an optical motion capture environment. Tracking the full degrees of freedoms of the hand and finger motions without any hindrances is a challenging task in optical motion capture measurements. Attaching markers on every finger and hand joint makes …
-
Bayesian models for improving joint kinematic measures in gait analysis
… on the surface of the skin and recorded by optical motion capture systems. Traditionally researchers have used optimization techniques which aim to reduce errors well described by white noise. These methods provide point estimates but fail to quantify uncertainties. This thesis improves on …
-
A Low-Cost RGB-Based Multi-Camera Motion Capture System for Metric 3D Tracking of Mobile Robots
Motion capture is a fundamental tool in experimental robotics, biomechanics, and human–machine interaction, where accurate three-dimensional position estimation is required for system validation, performance analysis, and reproducibility. Commercial optical motion capture systems achieve high …
-
INERTIAL MOTION CAPTURE SYSTEM FOR BIOMECHANICAL ANALYSIS IN PRESSURE SUITS
… providing a new capability for quantifying the motion of the human inside a space suit. Based on an array of six microprocessors and eighteen microelectromechanical (MEMS) inertial measurement units (IMUs), the Body Pose Measurement System (BPMS) allows the monitoring of the kinematics of the …
-
Classifying Visually Defined Varus Thrust in Knee Osteoarthritis Using Wearable Inertial Sensors and Markerless Motion Analysis
… as the reference standard, while markerless optical motion capture and wearable inertial sensor data were collected concurrently. Visual VT presence was initially assessed using a discrete scale that was based on the number of times it was observed, across multiple walking passes made by each …
-
High-throughput kinematic tracking of bird wings using inertial sensor arrays
… maneuvers primarily through variation in the motion of their wings. It is for this reason that an understanding of wing kinematics is of broad interest to the study of the physics and control of bird flight. However, current optical approaches to animal motion capture struggle to automate the …
-
A self-contained motion capture platform for e-textiles
… are increasingly prevalent in today's society. Motion capture is one of many potential applications for on-body electronic systems. Self-contained motion capture applications require information from sensors distributed throughout the body on a "smart" garment. Therefore, this thesis presents …
-
Acquiring 3D Full-body Motion from Noisy and Ambiguous Input
Natural human motion is highly demanded and widely used in a variety of applications such as video games and virtual realities. However, acquisition of full-body motion remains challenging because the system must be capable of accurately capturing a wide variety of human actions and does not …
-
Inertial Measurement Unit-Based Gait Event Detection in Healthy and Neurological Cohorts
… compared to reference events obtained with an optical motion capture system or pressure insoles. Based on the excellent performance, it is concluded that the DL algorithm is well suited for continuous long-term monitoring of gait in the habitual environment.
-
Capturing fast motion with consumer grade unsynchronized rolling-shutter cameras
Motion capture plays an important role in a wide range of fields including film production, game industry, sports analysis and medicine. However, commercial optical motion capture systems are expensive due to their reliance on high speed high resolution cameras and accurate shutter synchronization. …
-
Non-invasive Assessment and Compensation of Soft-tissue Artefacts in Hip Joint Kinematics
… the soft tissue artefact; this is the relative motion between the markers and the underlying bone due to the muscle and skin deformation. To solve this issue, we present a non-invasive method to assess and reduce the effect of the soft tissue artefact using optical motion capture data and tissue …
Page 1 of 6