An optical particle counter for the regular application onboard a passenger aircraft: instrument modification, characterization and results from the first year of operation
To understand the contribution of aerosol particles to radiative forcing and heterogeneous chemical processes in the upper troposphere and lowermost stratosphere (UT/LMS), the knowledge of the particle size distribution is mandatory. Unfortunately, measurements in the UT/LMS are costly. Research …
-
Use of a convective emission chamber to study particle resuspension
… C),$ and relative humidity (30-80%). Particle resuspension rates were measured with a laser based optical particle counter for various combinations of environmental conditions with and without the presence of mechanical disturbance of the source. The resuspension rates for the various …
-
A Hot-Wire Anemometer for Particle Counters
… shown to be promising. One such device is the optical particle counter. The particle counter functions by having laminar airflow with constant velocity traverse the path of a laser beam within an airflow channel. This thesis presents the design and integration of a hot-wire anemometer into the …
-
Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Indoor Exposure
… to public health and public health education. Optical particle counters are of interest in this regard. However, these lower-cost sensors are generally expected to lack the quality paid for in higher-cost sensors, thus leaving the question of their efficacy, especially at different …
-
A STUDY ON THE IMPACT OF FILTRATION ON SOME KNOWN AIR CONTAMINANTS
… particulate distribution was determined using an optical particle counter while the Andersen single stage sampler was used to assay bioaerosols. As for sampling of TVOCs, a multi-Gas monitor and multi-point Sampler & Doser were used. The effectiveness of the various filtration strategies were …
-
Effects of Optical Configuration and Sampling Efficiency on the Response of Low-Cost Optical Particle Counters
… and particulate matter (PM). A Low-cost Optical Particle Counter (OPC), costing less than 50 USD, is an example of such technologies. Currently, OPCs are widely used to measure the concentration of particle matter in ambient air. While these low-cost air quality sensors are widely …
-
A Lab-based Study for the Generation and Characterization of Particle Emission from Composite Materials Containing Carbon Nanotubes
… to measure and characterize the emission of particles during the sanding of composite materials containing carbon nanotubes (CNTs). The experimental setup consisted of a sand-blasting cabinet with HEPA-filtered air intakes. An electrical motor outside the cabinet was connected to a pulley …
-
Performance comparison of the Nanozen Dustcount personal real-time monitor with a conventional respirable dust exposure sampling method
… from mining operations varies in composition and particle size, influencing its health impacts. Safeguarding workers' health has been a legislated priority since 1911, with legislation mandating exposure monitoring and the implementation of control measures. Conventional gravimetric sampling is …
-
Detection and quantification of volcanic ash for aircraft hazard mitigation
… Scanning electron microscope (SEM) stubs and an optical particle counter were used to look at particle distributions and concentrations in both situations, with the limitations of these sensors being explored. Using the ash-box allows particles to be contained within an enclosed space and their …
-
Seeking Cleaner Air - Accessible Air Quality Monitoring and Event Diagnosis
… cleaner air. To achieve this goal, a low-cost optical particle counter is created for incorporation into a wireless sensor network (WSN), including the exploration of novel methods for improving the quality of such a sensor. A WSN is developed using the aforementioned sensors, along with a …
-
Characterization of a two-cycle engine and evaluation of its use as a particle generator
… of the engine test stand as a laboratory particle generator. The particle generator could be used to produce particles with diameters ranging from less than 0.1 to 5 microns (µm) to assist in the laboratory evaluation of particulate matter air pollution control for small particles.</p> …
-
Impact of coal-carrying trains on particulate matter concentrations in the Lower Mainland region of British Columbia, Canada
… during August and September 2014, using a GRIMM optical particle counter that measured PM concentration at various size ranges. A select number of passing trains were confirmed visually, while the majority of passages were identified with audio data recorded by a microphone. A horizontally …
-
Occupational exposure assessment for nanoparticles.
… various aspects of assessing exposure to nanoparticles and monitoring methods. The first section examines the appropriateness of different exposure metrics using multiple-metric measurements that were carried out in multiple locations of workplaces generating incidental nanoparticles to …
-
Occupational Exposure To Cooking Emissions And Evaluation Of Ventilation System In Restaurant Kitchens
… potential exposure to aldehydes and respirable particles among restaurant kitchen workers and to examine the ventilation performance of the kitchen exhaust hoods. Methods: There were three restaurants recruited for this study and they cooked seafood/poultry (Restaurant 1), farm style foods …
-
Automatic Particle Counting Using An Acoustic Transducer
Aerosol particle detection and determination finds important applications in the commercial, military and aerospace sectors. Monitoring of clean room environments, and spacecraft integration and check out facilities are some of the most important aplications. In the early days test filters were …
-
Volcanic Aerosols in the Upper Troposphere and Stratosphere – Aircraft- and Satellite-Based Observations
… source of variability in the stratospheric particle concentration as they inject SO2 that is subsequently converted into sulphate particles. No major perturbation of the stratospheric aerosol load has been observed since the large eruption of Pinatubo in 1991, but several moderate eruptions …
-
Studies of Volcanic Influence on Aerosols, Clouds and Climate
… Aerosol composition data were compared to particle size distributions obtained from onboard optical particle counter (OPC) measurements, demonstrating good agreement between the two analysis systems. The impact on climate was investigated using satellite observations of aerosol and optical …
-
Evaluation of the air quality of a residential home
… minimum during the period of data collection. An optical particle counter with multichannel analyzer was used for this study so that the concentration of particles in the particle size increments of interest could be measured simultaneously.</p> <p>Two different types of the commercially available …
-
Characterisation of airborne dust in a South African opencast iron ore mine : a pilot study
… exposure and health, especially for ultrafine particles (UFP). It is therefore imperative to characterise airborne dust containing micrometer and UFP size particles originating from specific areas to determine if there are physical- and chemical characteristics that may or may not have an …
-
Optical, microphysical and physico-chemical properties of aerosols using in situ and remote sensing measurements in Athens Metropolitan and the Eastern Mediterranean area
… Chapter 1, we present the physical, chemical and optical properties of aerosols, their impact on climate and health, and the factors affecting aerosol concentration in the study area. We also present the NTUA Raman Lidar (EOLE) and the operation principle of Wind Doppler Lidar. In Chapter 2, we …