Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Optical Transition Radiation (OTR)"”

  1. Establishment of a capability to measure optical transition radiation

    Optical transition radiation (OTR) can be used as a beam diagnostic system for charged particle beams. The experimental setup developed here demonstrates the capability to observe and measure OTR due to an electron beam from a linear accelerator. The setup is compact, simple, and readily adapted to …

    nps Repository record for Establishment of a capability to measure optical transition radiation (opens in a new tab)

  2. Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques

    Using Optical Transition Radiation (OTR) beam diagnostics and Dr. Rule's clear foil interferometer analytic code, the normalized emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the …

    nps Repository record for Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques (opens in a new tab)

  3. Measurement of electron beam emittance using optical transition radiation and development of a diffuse screen electron beam monitor

    … for measuring electron beam emittance using Optical Transition Radiation (OTR) with the Wartski Interferometer Method has been applied to the Naval Postgraduate School linear electron accelerator. Data for obtaining the emittance of the NPS linac has been collected. A chronology of the …

    nps Repository record for Measurement of electron beam emittance using optical transition radiation and development of a diffuse screen electron beam monitor (opens in a new tab)

  4. Helium scintillation background light in T2K’s optical transition radiation monitor

    … production and ensure target protection, the Optical Transition Radiation (OTR) monitor measures the profile and position of the proton beam. However, we observe a discrepancy between the beam width measured by the upstream beam monitors and OTR which could be caused by a broad background …

    ubc Repository record for Helium scintillation background light in T2K’s optical transition radiation monitor (opens in a new tab)

  5. Observation and analysis of optical transition radiation at the NPS linac and its use for diagnostics of electron beams

    An experimental technique for observing Optical Transition Radiation, (OTR), that is both simple and effective, is shown. A Macintosh II computer equipped with an image frame grabber board and Image software package allows for extensive analysis of the captured electron beam spot OTR patterns. The …

    nps Repository record for Observation and analysis of optical transition radiation at the NPS linac and its use for diagnostics of electron beams (opens in a new tab)

  6. Transition Radiation Monitors at the Canadian Light Source

    … line of the Canadian Light Source (CLS) synchrotron. The decision has been made to equip the specified facility locations with Transition Radiation Monitors (TRM) for diagnostic purposes. TRM systems use Optical Transition Radiation (OTR), the physical phenomenon by which a charged particle …

    sask Repository record for Transition Radiation Monitors at the Canadian Light Source (opens in a new tab)

  7. Novel radiometric imaging diagnostics for charged particle beams

    … sub-micron transverse beam profiles using optical transition radiation (OTR). Simulations were used to design a new imaging system, which was then installed at KEK (Japan). OTR images were then collected for a range of beam sizes. Comparisons were then made with simulations to successfully …

    liverpool Repository record for Novel radiometric imaging diagnostics for charged particle beams (opens in a new tab)

  8. Beam induced fluorescence monitor for high intensity beams

    … size of LHC beams at collision. Comparison with optical transition radiation (OTR) benchmarks showed agreement with ≤10% differences between the profiles, validating the absolute accuracy of the BGC. In addition, the monitor proved operationally valuable during EBTF beam commissioning, where it …

    liverpool Repository record for Beam induced fluorescence monitor for high intensity beams (opens in a new tab) Embargoed until 2027-02-01

  9. Analysis of Femtosecond Electron Bunches at the SwissFEL Injector Test Facility

    … As an electron beam collides with an optical transition radiation (OTR) foil, radiation is emitted. The radiation is collected by means of a mirror setup into an optical fibre and into an optical spectrometer. The spectral range of the spectrometer is 316 THz (950 nm) to 1364 THz (220 …

    epfl Repository record for Analysis of Femtosecond Electron Bunches at the SwissFEL Injector Test Facility (opens in a new tab)

  10. A view screen beam profile monitor for the ARIEL e-linac at TRIUMF

    … beam as it passes through the scintillation and Optical Transition Radiation beam targets, the subsequent thermal response of the targets, and a ray tracing optics simulation to optimize the configuration of the imaging optics. Bench test have been performed on the resulting optics design to …

    uvic Repository record for A view screen beam profile monitor for the ARIEL e-linac at TRIUMF (opens in a new tab)