Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"Optical fluence"”

  1. Development of a Near-Full-View Angle Coverage Photoacoustic Tomography System and Its Application Towards Optical Fluence Distribution Imaging

    … modality combining advantages of ultrasound and optical imaging. However, on the acoustic detection side, limited-view angle coverage and limited-detector bandwidth are common key issues in PAT systems that result in unwanted artifacts. While analytical and simulation studies of limited-view …

    uwo Repository record for Development of a Near-Full-View Angle Coverage Photoacoustic Tomography System and Its Application Towards Optical Fluence Distribution Imaging (opens in a new tab)

  2. Multi-spectral Deep Tissue Quantitative Photoacoustic Imaging

    … (PAT) detects the acoustic signals generated by optical absorption from chromophores. Using oxy- and deoxy-hemoglobin, multi-spectral PAT can image vasculature structure, and provide functional information. Most of the current PAT imaging studies face four challenges: heterogeneous fluence …

    duke Repository record for Multi-spectral Deep Tissue Quantitative Photoacoustic Imaging (opens in a new tab)

  3. System development and clinical applications of the handheld PA/US dual mode imaging system

    … progresses in the past two decades. By combing optical contrast with ultrasound detection, PAI can maintain high spatial resolution in deeper regions. Furthermore, with the aid of multispectral imaging, PAI can reveal functional information such as oxygenation saturation (SO2), which is closely …

    gatech Repository record for System development and clinical applications of the handheld PA/US dual mode imaging system (opens in a new tab)

  4. Matrix Method for Modeling Fluence Distributions in Anisotropic Scattering Media

    Determining the optical fluence from any source in highly scattering tissue can be a time consuming process. Previous methods have either been shown to be costly in terms of time, or produce erroneous results. Herein, the Matrix Method is proposed. This method attempts to use matrices to propagate …

    alberta Repository record for Matrix Method for Modeling Fluence Distributions in Anisotropic Scattering Media (opens in a new tab)

  5. Optical nonlinearities in semiconductor doped glass channel waveguides.

    The nonlinear optical properties of a semiconductor-doped glass (SDG) channel waveguide were measured on a picosecond time-scale; namely, fluence-dependent changes in the absorption and the refractive index as well as the relaxation time of the nonlinearity. Slower, thermally-induced changes in the …

    arizona-thes Repository record for Optical nonlinearities in semiconductor doped glass channel waveguides. (opens in a new tab)

  6. Laser Optoacoustic Imaging System for Molecular and Functional Imaging Research in Small Animal Models

    … imaging where resolution and contrast of pure optical imaging methods are limited by the strong optical scattering. The dominating tissue chromophores in the spectral range of laser wavelengths (650 nm to 1100 nm) that penetrate deep within tissues are hemoglobin and oxyhemoglobin of blood. …

    houston Repository record for Laser Optoacoustic Imaging System for Molecular and Functional Imaging Research in Small Animal Models (opens in a new tab)

  7. Optoacoustic neuromodulation mediated by fiber devices and blood

    … activity through electrical, magnetic, acoustic, optical, or chemical approaches. By enabling targeted and reversible manipulation, neuromodulation supports causal investigations of brain function and provides effective therapeutic strategies for conditions such as Parkinson’s disease, epilepsy, …

    bu Repository record for Optoacoustic neuromodulation mediated by fiber devices and blood (opens in a new tab)

  8. Multiple lateral photo-Dember terahertz emitters

    … modelling to demonstrate dipole suppression. Optical fluence, beam position and polarisation are characterised within GaAs LPD emitters with SI-GaAs showing a competing generation mechanism from the Schottky barrier at high fluences. We find that the emitter dependence on optical polarisation …

    soton Repository record for Multiple lateral photo-Dember terahertz emitters (opens in a new tab)

  9. Photoacoustic imaging with clinical, preclinical, and quantitative applications

    … biomedical imaging modality that combines optical absorption contrast with ultrasonic resolution and imaging depth. Major research has been carried out into PAI in recent years, and as a result PAI is rapidly being established as a mainstream imaging modality in both biological research and …

    galway Repository record for Photoacoustic imaging with clinical, preclinical, and quantitative applications (opens in a new tab)

  10. Quantification and Reconstruction in Photoacoustic Tomography

    Optical absorption is closely associated with many physiological important parameters, such as the concentration and oxygen saturation of hemoglobin. Conventionally, accurate quantification in PAT requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection …

    wustl Repository record for Quantification and Reconstruction in Photoacoustic Tomography (opens in a new tab)

  11. Laser ablation-based fabrication of a microchip capillary electrophoresis device for antibiotic detection in dairy

    … roughness for both materials as functions of optical fluence, pulse frequency, and scanning velocity. Optical fluences ranging from 30 J/cm² to 185 J/cm², and pulse frequencies ranging from 20 kHz to 60 kHz are explored. In the optimized fabrication process, surface roughness as low as 2.14 …

    ubc Repository record for Laser ablation-based fabrication of a microchip capillary electrophoresis device for antibiotic detection in dairy (opens in a new tab)

  12. Development of Quantitative Ultrasound-Mediated Molecular Imaging of The Tumor Microenvironment

    … (PA) imaging methods were developed along with optical fluence modeling techniques in order to improve accuracy and precision of SO2 estimates. SO2 estimation accuracy was shown to improve from 16.8% error to 3.2% error with a precision of 2.3% in tissue-mimicking phantoms, while in vivo …

    uthsc Repository record for Development of Quantitative Ultrasound-Mediated Molecular Imaging of The Tumor Microenvironment (opens in a new tab)

  13. Integration of terahertz and microfluidics technologies for effective spectroscopic analysis on a chip

    … under bias fields up to 5.0 kV/cm and optical fluences up to 340 μJ/cm² for two PC materials being semi-insulating (SI) GaAs and SI-InP. With respect to the bias field, the two PC materials behave contrarily due to the space-charge-limited current in SI-GaAs and sustained current in …

    ubc Repository record for Integration of terahertz and microfluidics technologies for effective spectroscopic analysis on a chip (opens in a new tab)

  14. Photoinduced Manipulation of the Molecular Assembly in Heteroleptic Titanium Metal Alkoxides for Use in Optical Devices

    … the potential for impact in a broad range of optical, chemical, and biological applications. Heteroleptic titanium metal alkoxides (OPy)₂Ti(4MP) ₂ and (OPy)₂Ti(TAP)₂, where OPy = OC₆H₆N, 4MP = OC₆H₄(SH)-4, and TAP = OC₆H₂(CH₂N(CH₃)₂)₃-2,4,6 were investigated as precursors for thin film and …

    arizona-thes Repository record for Photoinduced Manipulation of the Molecular Assembly in Heteroleptic Titanium Metal Alkoxides for Use in Optical Devices (opens in a new tab)

  15. Improved Breast Cancer Theranostics Using Photoacoustic And Ultrasound Tomography

    … an important marker for cancer, like ignoring optical fluence and SS variation. Both assumptions introduce biases into quantitative measurements and must be accounted for to improve the accuracy of oxygenation, etc measurements. Here, I propose to develop PAT reconstruction algorithm using …

    wayne-thes Repository record for Improved Breast Cancer Theranostics Using Photoacoustic And Ultrasound Tomography (opens in a new tab)

  16. Ultrafast polar vortex dynamics on PTO/STO superlattices: instrument and method development for high-resolution UEM

    … an asymmetric character at low pump laser fluence, with non-uniform melting of the vortex topology observed among domains of various orientations and sizes. Moreover, as the optical fluence increased, the asymmetric melting behavior was recovered back to a nearly symmetric fashion, …

    umn Repository record for Ultrafast polar vortex dynamics on PTO/STO superlattices: instrument and method development for high-resolution UEM (opens in a new tab)

  17. Photocurrent efficiency and limitations in 4H-SiC photoconductive semiconductor switches

    … results and analysis detailing the effects of optical wavelength (295-375~nm), optical fluence (30-30,000~$\mu$J/cm$^{2}$), DC bias voltage (0-4~kV) and load resistance (10-300~$\Omega$) on photocurrent efficiency in bulk-lateral SiC PCSSs are presented. Photocurrent efficiency in bulk-lateral …

    ttu Repository record for Photocurrent efficiency and limitations in 4H-SiC photoconductive semiconductor switches (opens in a new tab)

  18. Free-hand Photoacoustic Imaging of Breast Cancer Tissue

    … goals was to develop a method for estimating optical properties of imaging phantoms to assist in the evaluation of imaging devices under development. In this thesis, we present (i) a novel method for optical property estimation in turbid media for PAI phantom quality assurance, (ii) perform a …

    uwo Repository record for Free-hand Photoacoustic Imaging of Breast Cancer Tissue (opens in a new tab)

  19. Enabling Real Time Ultrafast Pulse Characterization for Compressively Sampled X-ray Absorption Spectroscopy

    … affects; validation is done via calculation of optical fluence and quantification of B integral. A key aspect of this research is the characterization of the laser to ensure a reliable measurement matrix for application of CS to XAFS spectroscopy. To achieve precise control and optimization of …

    zurich Repository record for Enabling Real Time Ultrafast Pulse Characterization for Compressively Sampled X-ray Absorption Spectroscopy (opens in a new tab)

  20. Technical development of photoacoustic microvascular imaging

    … (PA) imaging (PAI) technology combines the optical contrast of light absorption with the deep penetration depth of ultrasound (US), offering promise in biomedical imaging. Compared with other vascular imaging techniques, PAI has unique advantages and demonstrates great potential for …

    gatech Repository record for Technical development of photoacoustic microvascular imaging (opens in a new tab)

Page 1 of 2