Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 48 for “"Optical path difference"”

  1. Prototyping of a two-beam laser interferometer for measurement of optical turbulence along extended paths

    … that provides real-time measurement of the optical path difference, and subsequent phase distortion, caused by atmospheric turbulence along an extended horizontal path. Prototype's signal processing incorporates use of specialized phase comparator circuit developed by author's advisor, D. S. …

    nps Repository record for Prototyping of a two-beam laser interferometer for measurement of optical turbulence along extended paths (opens in a new tab)

  2. Short wave infrared camera design and focal plane analysis

    … system. The design has been done using ZEMAX optical design program and the performance of the system at focal plane was investigated by the help of Seidel aberrations, Modulation transfer Function (MTF), Spot diagram and Optical Path Difference (OPD) fan plot analyses.

    metu Repository record for Short wave infrared camera design and focal plane analysis (opens in a new tab)

  3. MIR spiral fourier transform spectrometer

    … infrared spectrometers require larger optical components and high-precision mechanical components to implement. Manufacture and adjustment of these elements and components require considerable time and cost, and make the spectrometer large in size and weight. But the emergence of …

    soton Repository record for MIR spiral fourier transform spectrometer (opens in a new tab)

  4. LARGE AREA TUNABLE LIQUID CRYSTAL LENS

    … by very slow switching speeds due to the large optical path difference (OPD)required. To reduce the switching time of the lens, the thickness is controlled through theapplication of several phase segments, similar to the design of a Fresnel lens. A main point ofthis dissertation is the design of …

    ohiolink Repository record for LARGE AREA TUNABLE LIQUID CRYSTAL LENS (opens in a new tab)

  5. Interferometric Metrology Using Reprogrammable Binary Holograms

    … comparison reference surface to minimise the optical path difference and hence enhance the dynamic range. An alternative to this is to use a computer generated hologram to act as the reference wave, or to correct a spherical reference wave to match a highly aspheric optic in order to achieve a …

    durham Repository record for Interferometric Metrology Using Reprogrammable Binary Holograms (opens in a new tab)

  6. Measurement of the coherence length of atomic two-photon radiation

    … on one side of the source as a function of the optical path difference 6 introduced by the multiwave plate between the orthogonally polarized components is determined by measuring the Stokes' parameters. The results confirm the dependence of the depolarizing effect of the multiwave plate on 6, …

    stirling Repository record for Measurement of the coherence length of atomic two-photon radiation (opens in a new tab)

  7. Interferometry in astronomy

    … world-class representatives of both radio and optical interferometry, namely the IRAM interferometer and the GRAVITY instrument at the Very Large Telescope Interferometer. GRAVITY observes two sky objects simultaneously at wavelengths of ~ 2 µm. Measuring the differential optical path …

    lmu-germany Repository record for Interferometry in astronomy (opens in a new tab)

  8. Versatile and Sensitive Optical Sensing and Imaging with Spectral Interferometry

    Optical interferometry treats light as a wave. Light has not only brightness information, but also phase information, representing the number of cycles traveled, like hands on a clock. This phase information describes how far a beam of light travels in one path relative to another. Splitting light …

    vt Repository record for Versatile and Sensitive Optical Sensing and Imaging with Spectral Interferometry (opens in a new tab)

  9. Caracterização em tempo real da birrefringência de forma do sistema PS/PP por técnica reo-óptica

    The rheo-optical behavior of polystyrene (PS), polypropylene (PP) and immiscible dilute mixtures of these polymers was studied in order to determine the flow birefringence and form birefringence of these materials. The transmitted light intensity between cross-polarizers (IN) was measured using an …

    brazil-ufscar Repository record for Caracterização em tempo real da birrefringência de forma do sistema PS/PP por técnica reo-óptica (opens in a new tab)

  10. Characterization of Herbig Ae/Be stars and PRIMA FSU-A as a fringe tracker for MIDI

    … only 0.6 AU was discovered using high-resolution optical and near-infrared spectroscopy. In the second part of this work, a new observation mode at VLTI is presented. The mid-infrared interferometric instrument MIDI is used with a near-infrared beam-combiner, called PRIMA FSU-A. The latter one …

    heid-diss Repository record for Characterization of Herbig Ae/Be stars and PRIMA FSU-A as a fringe tracker for MIDI (opens in a new tab)

  11. Simulation of thermal, mechanical and optical behavior of yag ceramics with increasing Nd3+ concentration under lasing conditions.

    Two-dimensional thermal, mechanical and optical simulations are carried out to investigate the effect of Nd3+ concentration on thermal, mechanical and optical behavior of Nd:YAG ceramic laser materials under continuous wave laser operation. In the analyses, rods are pumped longitudinally with laser …

    metu Repository record for Simulation of thermal, mechanical and optical behavior of yag ceramics with increasing Nd3+ concentration under lasing conditions. (opens in a new tab)

  12. Dispositivo óptico para medida em tempo real da birrefringência de polímeros durante a extrusão

    … were the development and application of an optical device to measure in real time the flow induced birefringence during the polymer extrusion. The linearly polarized light intensity transmitted through the molten polymer flowing in the slit-die is converted into birefringence via its …

    brazil-ufscar Repository record for Dispositivo óptico para medida em tempo real da birrefringência de polímeros durante a extrusão (opens in a new tab)

  13. Cascaded singlemode-multimode-singlemode fiber structure for directional bending sensing

    … When the CSMS fiber structure is bent, the optical path difference will be changed, causing the resonant wavelength of the Vernier spectrum to shift. Exceptionally, since the bending sensitivity is different under different bending direction, different bending direction range from 0° to 360° …

    nanyang Repository record for Cascaded singlemode-multimode-singlemode fiber structure for directional bending sensing (opens in a new tab)

  14. Monitoramento em tempo real da orientação molecular de poliestireno e em misturas com polimetilmetacrilato durante a extrusão

    … the polarized transmitted light intensity. The optical device is attached to the extruder exit by means of a slit-die possessing bores fitted with borosilicate transparent glass windows where light may go through to reach the flow. Upon pressurization, the windows internal structure changes …

    brazil-ufscar Repository record for Monitoramento em tempo real da orientação molecular de poliestireno e em misturas com polimetilmetacrilato durante a extrusão (opens in a new tab)

  15. New type transflective liquid crystal displays

    … a double cell gap approach to maintain the same optical characteristics with increasing the voltage. In the double cell gap approach, the cell gap for transmissive mode is doubled to that for the reflective mode. So that, both reflective and transmissive mode has the same optical path difference. …

    hkust Repository record for New type transflective liquid crystal displays (opens in a new tab)

  16. Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)

    … fringe patterns which can be used to measure the optical path difference of the sensor. Spectral characteristics were measured for 850nm VCSELs to determine the combination of dc bias current, modulation current amplitude and modulation frequency for which single mode VCSEL operation and regular …

    tamu Repository record for Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL) (opens in a new tab)

  17. Pixelated Mask Polarization Based Spatial Carrier Interference Microscopy

    … the test object. The scanning changes the optical path difference between the interferometer arms thus inducing the phase shifts. While both methods scan the test surface, spatial methods acquire all of the information needed to calculate fringe contrast and phase simultaneously while the …

    arizona-thes Repository record for Pixelated Mask Polarization Based Spatial Carrier Interference Microscopy (opens in a new tab)

  18. Noise Reduction in THz-TDS Dielectric Characterization of Thin Films with THz Interferometry

    … Using the tilted slab experiment an optical path difference of 1/700 pulse coherence length between propagation through sample and reference has been measured. Results from photo-induced index change of a semi-conducting wafer show an optical path length difference of 1/1250 with good …

    okstate Repository record for Noise Reduction in THz-TDS Dielectric Characterization of Thin Films with THz Interferometry (opens in a new tab)

  19. Dynamic Coherence Scanning Interferometry to Characterise the Einstein Telescope Prototype Mirror under Cryogenic Conditions

    … The metrology instrument incorporates a novel optical phase mask and a microlens array, enabling the acquisition of the full white light interference pattern at multiple local points on the mirror under characterisation within a single camera frame. This contrasts with traditional …

    liege Repository record for Dynamic Coherence Scanning Interferometry to Characterise the Einstein Telescope Prototype Mirror under Cryogenic Conditions (opens in a new tab)

  20. Spectrometer-based Optical Coherence Tomography Systems with Extended Functionality

    Optical coherence tomography (OCT) has evolved over the last two decades to become a major optical imaging modality in the biomedical optics field. By performing high-resolution, multi-dimensional imaging of translucent structures, it enables real-time tissue imaging in-vivo and in-situ with …

    kent Repository record for Spectrometer-based Optical Coherence Tomography Systems with Extended Functionality (opens in a new tab)

Page 1 of 3