Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 4 of 4 for “"Optison"”

  1. Assessment of coronary artery stenosis using myocardial contrast echocardiography.

    … undertaken to establish both a means of infusing Optison (GE Healthcare, UK), and of displaying static frame contrast signal using Power Contrast Imaging (Acuson Sequoia, Siemens Medical Solutions, Mountain View, CA, USA.). Three Optison concentrations, five infusion rates, and five trigger …

    ucl Repository record for Assessment of coronary artery stenosis using myocardial contrast echocardiography. (opens in a new tab)

  2. The Use of Ultrasound-Targeted Microbubble Destruction in Mediated Delivery of a Gadolinium Magnetic Resonance Imaging Contrast Agent Into Fibroblast Cells In Vitro

    … microbubble destruction using Optison(tm) microbubbles to deliver Gd-DOTA-4iBA into fibroblast cells displays negligible T1 shortening at 4.7T over controls. Further experiments are planned to validate these observations with other MRI contrast agents and other forms of …

    utswmed Repository record for The Use of Ultrasound-Targeted Microbubble Destruction in Mediated Delivery of a Gadolinium Magnetic Resonance Imaging Contrast Agent Into Fibroblast Cells In Vitro (opens in a new tab)

  3. <i>In vitro</i> Characterization of Echogenic Liposomes (ELIP) for Ultrasonic Delivery of Recombinant Tissue-type Plasminogen Activator (rt-PA)

    … destruction thresholds of an FDA-approved UCA, Optison®, and unmodified ELIP utilizing a clinical diagnostic ultrasound scanner (Porter <i>et al.</i>, 2006; Smith <i>et al.</i>, 2007a). Recently, in vitro studies were performed with an innovative drug-encapsulated contrast agent, rt-PA-loaded …

    ohiolink Repository record for <i>In vitro</i> Characterization of Echogenic Liposomes (ELIP) for Ultrasonic Delivery of Recombinant Tissue-type Plasminogen Activator (rt-PA) (opens in a new tab)

  4. Vergleich der diagnostischen Wertigkeit der Dobutamin-Kontraststressechokardiographie und der Myokardszintigraphie mit der Referenzmethode Druckdrahtmessung zur Beurteilung mittelgradiger Koronarstenosen

    … von Kontrastmitteln der 2. Generation (Optison® bzw. Sonovue®). Die Interpretation aller Echokardiogramme erfolgte gemäß dem 16 Segmentmodell der American Society of Echocardiography. Die Endokarddelineation wurde sowohl in Ruhe als auch unter Belastung bewertet, wobei eine signifikante …

    wurz-thes Repository record for Vergleich der diagnostischen Wertigkeit der Dobutamin-Kontraststressechokardiographie und der Myokardszintigraphie mit der Referenzmethode Druckdrahtmessung zur Beurteilung mittelgradiger Koronarstenosen (opens in a new tab)