Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 37 for “"Optode"”.
-
Soil Oxygen Monitoring with Fibre Optode Sensors: Experimental Evaluation in Soil Columns under Fluctuating Water Table and Freeze Thaw Conditions
… A luminescence-based, Multi-Fibre Optode (MuFO) microsensor technique was developed to measure O2 concentrations in fully and partially water-saturated systems. The technique relies on the conversion of high-resolution digital images of sensor-emitted light into O2 concentrations …
-
Autonomous ocean carbon system observations from gliders
… and fast response. For the first time, a CO2 optode (Aanderaa), a potentiometric pH glass electrode (Fluidion) and a spectrophotometric labon-chip pH sensor (UK National Oceanography Centre) were tested on gliders. The CO2 optode was deployed for 8 months in the Norwegian Sea, with an O2 …
-
An assessment of Eddy Correlation technique in marine habitats
… Microelectrode system (ECE) and Eddy Correlation Optode system (ECO) for O₂ flux measurement in seagrass meadows and benthic organisms in the laboratory and field. Although EC has been used in aquatic system for over a decade, this system is still under development to gain robust results. …
-
Isopycnal shoaling causes interannual variability in oxygen on isopycnals in the subarctic Northeast Pacific
… eight Argo profiling floats equipped with oxygen optode sensors to assess the 2008—2016 interannual variability of subsurface dissolved oxygen near OSP. I developed a method to implement a time-lag correction to the optode profiles using high frequency CTD data and used reference profiles from the …
-
Neural correlates of executed and imagined joystick directional movements: a functional near-infrared spectroscopy study
… literature, studies were limited by low-density optode layouts and/or task designs which did not represent the motor goal. The present study was designed to enhance our understanding of the capabilities of fNIRS by utilizing a high-density optode array and an experimental task that closely …
-
Development of a Biosensor to Predict Activated Sludge Deflocculation, and the Link Between Chlorination and Potassium Efflux
… with a fluorescence-based sensor called an optode. The components of the system satisfy the project requirements, which include minimal expense (both operation and manufacture), on-line capability and minimal maintenance. The research conducted to date demonstrates the ability of the …
-
Stimuli responsive polymer gels for sensing applications
… IL. The IL simplified polymer gel is termed an optode within this chapter as (a) it is prepared the same manner as optodes, (b) the IL performs many of the same functions as previous materials used in optode design and (c) the analyte or ion movement between the aqueous and organic phases …
-
Analyzing human brain functional near-infrared spectroscopy data with transformer model
… confounding signals from motions, including optode shifts or non-linear correlation between motion and physiological responses, are hard to be reduced or eliminated with traditional methods including tCCA-GLM. This study proposes a transformer-based model aiming to remove local and systemic …
-
Characterisation of pH and pCO2 optodes towards high resolution in situ ocean deployment
… for in situ seawater deployments.<br/><br/>The optode sensing spots were illuminated with low intensity light (0.2 mA, 0.72 mWatt), and the time-domain dual lifetime referencing analysis technique was applied to maximise the lifetime of the spot and reduce overall power consumption of the …
-
Oxygen saturation surrounding deep-water formation events in the Labrador Sea from Argo-O2 data
… of wintertime convection. Four of the six optode oxygen sensors displayed in situ drift of -2.98 μmol O2 kg-1 year-1 on average, which we corrected to stable deep-water oxygen values from repeat hydrography. Observations of low oxygen intrusions during restratification and a simple mixing …
-
Photosynthetic response of Scandinavian kelp forests to stratospheric ozone depletion
… employing two emerging procedures: a fiber-optic optode system for measuring dissolved oxygen and stable isotope (13C) labeling of tissue C-uptake. The final production model was tested under different ozone depletion, tide, and cloud cover scenarios. Model simulations demonstrate that ozone …
-
The Metabolic Physiology of Planarian Flatworms
… can reliably be measured in planaria using optode closed respirometry, and also provided a reliable method for measuring wet mass in planaria, which has been a challenge to researchers in the past. This research revealed that oxygen consumption in S. mediterranea is 1.5-2.1X greater in the …
-
High-Resolution In Situ Oxygen-Argon Studies of Surface Biological and Physical Processes in the Polar Oceans
… functioning that we measure underway using an optode and Equilibrator Inlet Mass Spectrometry (EIMS). Total O2 measurements are common throughout the historical and autonomous record but are influenced by biological (net metabolic balance) and physical (temperature, salinity, pressure changes, …
-
Explaining soil biogeochemical responses after fire
… °C). Using optical chemical sensing with planar ‘optodes’, pH and dissolved O2 concentration were tracked spatially (depth and width) with a resolution of 360 µm per pixel for 72 hours. We show that imaging data from planar optodes can be correlated with microbial activity as quantified via …
-
Hyperoxia Mechanisms in a Neonatal Rat Model of Febrile Seizures
… Methods: Rat pups were implanted with an optode and an electrode into contralateral dorsal hippocampi on postnatal day (P)8. Pups then received lipopolysaccharide injections four days prior to and including P12. On P12 external heat was used to induce a seizure in the pups. Pups were …
-
A wearable near-infrared diffuse optical system for monitoring in vivo breast tumor hemodynamics during chemotherapy infusions
… and electrical components. Second, a high optode-density flexible probe was design and fabricated which can conform to the curved surface of the human breast. Finally, a control box with miniaturized electronics and high-speed electronics was designed and fabricated to complete a …
-
Assessing cognitive surgical expertise using mental imagery and functional neuroimaging
… salient events of the operative dictation. Optode montage (developed during preliminary testing) covered prefrontal, occipital, and sensorimotor regions. Measurement of the fluctuations in deoxyhemoglobin and oxyhemoglobin concentrations during the cognitive task was obtained for each …
-
Next generation near infrared (NIR) and shortwave infrared (SWIR) wearables for breast cancer imaging
… and validated in this project, including a high-optode density NIR probe for monitoring hemodynamics and a first-generation SWIR probe for quantifying water and lipid. Measurements on tissue-mimicking channel flow phantoms confirmed the ability of the NIR probe to quantify absorption contrast in …
-
Optical and electrochemical transduction of calixarene host-guest chemistry
… cahx[4]arene ligand was developed. The optode membranes were prepared from a PVC cocktail composition and exhibited significant colour change on exposure to gaseous ammonia. Some preliminary studies involving coated optical fibres together with a mass flow controller were also earned out …
-
Cancer Assessment with Optical Imaging: Algorithms and Machine Learning
… dissertation, we develop algorithms to correct optode coupling errors and reduce image artifacts in DOT clinical applications. A deep learning-based data generation method is then presented to simplify data acquisition and processing and mitigate mismatch problems in DOT difference imaging. …
Page 1 of 2