Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 70 for “"Orifice Plate"”.
-
Modelling of the conical entrance orifice plate flow sensor
This thesis presents a model for conical entrance orifice plate flow sensor and the results of the applica-tion of the model. The model for the conical entrance orifice plate flow sensor was developed using a low Reynolds number k-e model of turbulence - the Lam and Bremhorst k-e model, and the …
-
Temperature Effect in Multiphase Flow Meter Using Slotted Orifice Plate
… oil and gas industries. A combination of slotted orifice plate and electrical impedance technique was investigated in order to provide further development of a new type of multiphase flow meter. Flow visualization was conducted in this study to show the performance of the slotted orifice plate to …
-
Simulation and Experimental Investigation of Fluid Mixing Enhancement with Orifice Plate
… carried out to investigate the effects of an orifice plate on mixing. Mixing efficiency is measured through the correlation of volume fraction to color light reflectivity, as dyes were introduced to the fluids being mixed. Volume fractions close to 0.5 indicate high mixing performance, and the …
-
Detonation Hazard Classification Based On The Critical Orifice Plate Diameter For Detonation Propagation
… spark. The second half of the tube contained orifice plates equally spaced at the tube diameter. Six different orifice plate diameters between 38.1 mm (1.5˝) and 76.2 mm (3˝), in increments of 6.4 mm (1/4˝) were used in the study. The average combustion front velocity was obtained from …
-
The Design, Experimentation, and Characterization of a High-Pressure Round-Edged Orifice Plate Test Facility
Orifice plates are commonly found in fluid measurement devices, piping systems, and engines. They are used as flow measurement devices, appear as restrictors in piping, or are used as fuel injectors inside internal combustion engines. While there are equations that predict the discharge coefficient …
-
Effectiveness Analysis of Slotted Orifice Plate Multiphase Flow Meter Coupled with Venturi Meter and Visualization Study
… and steady. Therefore, in this study a slotted orifice plate is used to homogenize the multiphase flow. Venturi meters are commonly used to measure the flow rate of a fluid. It uses a converging section of pipe to increase the velocity of the flow which causes pressure drop according to …
-
Effects of Simple Inlet and Outlet Edge Modification of a Thick Orifice Plate on Cavitating Choke Flow
… point of cavitation through six different orifice meters is examined. It will be determined which inlet or outlet geometry is most effective in raising the inception point of cavitation and flowrate capacity of an ordinary, square edged orifice meter. Using 3D axisymmetric ANSYS CFX …
-
Discharge Coefficient Performance of Venturi, Standard Concentric Orifice Plate, V-Cone, and Wedge Flow Meters at Small Reynolds Numbers
… performed in this area for the Venturi, standard orifice plate, V-cone, and wedge flow meters. The Computational Fluid Dynamics (CFD) program FLUENT© was used to perform the research, while GAMBIT© was used as the preprocessing tool for the flow meter models created. Heavy oil and water were used …
-
Characterization of Flow Homogeneity Downstream of a Slotted Orifice Plate in a Two-Phase Flow Using Electrical Resistance Tomography
… It has been experimentally proven that a slotted orifice plate is a better flow homogenizer than a standard orifice plate and a V-cone. However, the location downstream of the slotted orifice plate where the two-phase flow becomes most homogeneous is still not known. Knowing this would help in …
-
Synthesis of computations and experiments for obtaining pulsatile gas flow rates from dynamic pressure difference measurements across an orifice-plate meter
The use of conventional orifice-plate meter is typically restricted to measurements of steady flows. This study proposes a new and effective computational-experimental approach for measuring the time-varying (but steady-in-the-mean) nature of turbulent pulsatile gas flows. Low Mach number …
-
Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
In previous studies the slotted orifice plate has demonstrated superior performance characteristics to those of the standard orifice plate. In this study, these comparisons are investigated further. The response characteristics of the slotted orifice plate to the standard orifice plate and V-Cone …
-
Metal-rich Scales in the Reykjanes Geothermal System, SW Iceland: Sulfide Minerals in a Seawater-dominated Hydrothermal Environment
… loss during depressurization. Upstream of the orifice plate at high pressure (40 bar, 252°C) the precipitates consist mainly of sphalerite and chalcopyrite with a trace of galena and bornite. At the orifice plate of old wells, the pressure decreased sharply to 11 bar (188°C), resulting in …
-
On the Generation of Pipeline Acoustic Resonance
… is generated by placing two standard geometry orifice plates in the flow. Strong acoustic pressures exceeding 125 dB inside the pipe are generated with the orifice plate separation distance small (<2%) in comparison to the wavelength of the lowest frequency excited. The acoustic source is shown …
-
Response of a slotted plate flow meter to horizontal two phase flow
The slotted plate flow meter has been widely tested as an obstruction flow meter during the past several years. It has been tested for both single-phase flows as well as for two-phase flows. Previous studies have revealed that the slotted plate flow meter is always better in performance and …
-
Determination of frictional losses for fiberglass ducts
… for Fiberglass Ducts describes the design of an orifice plate measurement system for the testing and determination of frictional losses due to air flow in fiberglass ducts. The basis for the design came from ASHRAE standard 120P, "Methods of Testing to Determine Flow Resistance of HVAC Air Ducts …
-
Computer aided mathematical modelling of turbulent flow for orifice metering
… high Reynolds number turbulence through an orifice plate. The model developed for orifice plates was based on a particular closed form turbulent model: the k-ε two equation model developed at Imperial College, London and embodied in the TEACH-T finite difference computer code. A basic model …
-
Computational Fluid Dynamic (CFD) Modeling and Experimental Study of the Formation and Buoyancy-Driven Detachment of Bubbles in Variable Gravity Environments
… detachment of a gas bubble from an orifice submerged in a liquid. Specifically, the effect of gravitational acceleration and orifice plate material surface energy on a bubble's volume at detachment was measured. The research is presented in three phases. First, a theoretical force …
-
Two-Phase Flow Measurement of Geothermal Fluid
… The extensive field-testing of both two-phase orifice plate and Load Cells was undertaking on large diameter pipelines (≥10 inch) at several fields in Indonesia and New Zealand is described. Details of equipment design, site layout, installation and test procedures are also covered. The …
-
Detonation Characteristics of Dimethyl Ether, Methanol and Ethanol Air Mixtures
… ignition and subsequent flame acceleration using orifice plate obstacles in the first half of the tube, and via a gas driver with a short orifice plate obstacle section. Cell width measurements where obtained using the soot foil technique for fuel-air mixtures inside the detonation limits. The …
-
Modeling Two-Phase Flow in the Downcomer of a Once-Through Steam Generator using RELAP5/MOD2
… studied. Emphasis is also placed on modeling the orifice plate of the OTSG downcomer which has been added to stabilize pressure fluctuations between the downcomer and tube bundle of the OTSG. While several different schemes are explored for modeling the orifice plate, a branch connection with an …
Page 1 of 4