Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"Orthotics and Prosthetics"”.
-
Fabrication, Sensation and Control of Fluidic Elastomer Actuators and Their Application towards Hand Orthotics and Prosthetics
Due to their continuous and natural motion, fluidic elastomer actuators (FEAs) have shown potential in a range of robotic applications including prosthetics and orthotics. Despite their advantages and rapid developments, robots using these actuators still have several challenging issues to be …
-
Validity of a Self-Assessment Survey and Its Implications for Clinical Education and Practice Framework
Background: Researchers, educators, and accreditors in the medical and health professions have increasingly emphasized competency-based education and assessment. Professional requirements for evidence-based practice and continuing professional development require clinicians to self-assess their …
-
An Ethnographic Study of Orthotist-Prosthetist Culture
The Orthotics and Prosthetics (O&P) profession is defined by the provision of services and devices unique within the healthcare realm. The quality and nature of orthotic and prosthetic services varies considerably based on individuals’ training, experience, available resources, and culture where …
-
Creation of Hand Sensors and Orthotics to Capture and Replicate Human Movement and Forces
… due to the robust kinematic patterns in our hands and wrist. These forces and movements available at our hand allow us to manipulate objects as small as a sewing needle yet still lift multiple grocery bags at one time on a daily basis. Inability to use the upper extremities usually …
-
Towards Developing a Digital Workflow for Transradial (Below-Elbow) Prostheses
… prosthesis greatly enhances the independence and quality of life for individuals with upper-limb absence. As the healthcare industry transitions towards data-driven approaches, integrating digital technology into Orthotics and Prosthetics (O&P) holds immense potential to standardize clinical …
-
Bayesian Non-linear System Identification and Frequency Response Analysis with Application to Soft Smart Actuators
… to have a huge impact on the fields of robotics, orthotics and prosthetics due to their lightweight, high-strain and muscle-like properties. Like muscle, these actuators can be used in multiple roles, e.g. both as actuators and brakes, due their variable compliance. One important class of soft …
-
Investigations into the design of a wheelchair-mounted rehabilitation robotic manipulator
… manipulator for use by the physically disabled and elderly. A detailed review of world rehabilitation robotics research has been conducted, covering fifty-six projects. This identified the main areas of research, their scope and results. From this review, a critical investigation of past and …
-
Towards Socket Testing Standardization: Advancing Mock Residual Limbs for Transtibial Prosthetic Socket Testing Through 6DOF Gait Simulation
… prostheses. While technology used to create and augment sockets have been evolving, testing methods have not kept pace. The criterion standard for the testing of transtibial prostheses, ISO 10328, does not specify testing for the socket as a stand-alone unit beyond static compression testing …
-
Uneven Terrain Treadmill Training for Lower Limb Prosthesis Users: A Feasibility Study
… for falls which may limit mobility, confidence, and participation in daily activities. Current rehabilitation programs for this population rarely integrate surface training as an intervention, despite walking on different surfaces being a necessity to participate in the real world. This …
-
Development of software to estimate pressures on the residual limbs of amputees by means of a pylon mounted transducer
… Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown …
-
Development and Pilot Testing of a Surface Discrimination Test for People with Lower Limb Amputation
Introduction: There is a lack of understanding as to how sensory loss and sensory deficits impact those with LLA. The purpose of this research is to determine the extent to which people with LLA can discriminate between surfaces underfoot, in order to better understand the relationship between …
-
Abduction Contractures within Infants with Developmental Dysplasia of the Hip
… on their level of instability or dislocation and the infant is then prescribed a treatment. While Finite element models of dysplastic hips have been developed previously, a study that seeks to understand the contribution of an abduction contracture of the hip has yet to be performed. This …
-
Design Analysis and Control of Wearable Ankle Rehabilitation Robot
… or intimidating appearance due to use of heavy and bulky electromagnetic actuators. Wearable robots, owing to their biologically inspired design, compliant actuation, backdrivability and safe use, are better candidates for rehabilitation robots compared to industrial robots. In recent years, …
-
Development of a Novel Predictive Model and Prosthetic System to Assess Dynamic Leg Length Based Gait Biomechanics in Lower Limb Prosthesis Users
… for their missing extremity’s structure and function. Lower-limb prosthetic devices are developed with the goal of restoring biomechanical abilities and mitigating secondary health risks for users. However, biomechanical deficits for unilateral transfemoral prosthesis users are very …
-
The Use of a Pylon Mounted Transducer for Investigating the Gait of Transtibial Amputees
Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the …
-
A REVIEW OF FACTORS, SEATING DESIGN, AND SHAPE CAPTURE METHODS FOR REDUCING PRESSURE INJURY RISK
… (b) the impact of seating as an intervention, and (c) aims of the three-paper dissertation in addressing various aspects of pressure injury prevention. Each paper is unique and singular in its focus, yet all share the overlying aim of addressing pressure injury risk associated with wheelchair …
-
THE EFFECTS OF ORTHOTICS AND INCREASED PLANTAR SOLE MECHANORECEPTOR ACTIVATION ON TURNING PERFORMANCE IN INDIVIDUALS WITH PARKINSON’S DISEASE
Locomotion and turning are complex movement patterns essential to activities of daily living. Individuals with Parkinson’s disease (PD) report difficulties turning, often coupled with impaired balance and increased fear of falling. The purpose of this within-subject study was to determine if …
-
The Immediate Effects of the NuNee Patellar Support on Individuals with Patellofemoral Pain Syndrome
… muscular weakness or strength imbalances, and poor movement coordination leading to abnormal alignment or mal-tracking of the patella. Recent guidelines do not recommend the use of a knee orthosis due to a lack of evidence supporting their effectiveness. A new patellar support (NuNee, …
-
Exploring the relationship of intact limb knee joint loading with step lengths and step length symmetry in individuals with lower limb amputation
… experience intact limb knee pain, dysfunction, and osteoarthritis. These problems can worsen pre-existing reductions in mobility and quality of life that this population regularly experiences. It is widely accepted that knee joint loading is implicated in the development of knee joint issues, …
-
CHEMICAL AND POLYMER CHARACTERIZATION OF THE POTENTIAL MODES OF DEGRADATION OF AN INJECTABLE NUCLEUS PULPOSUS REPLACEMENT DEVICE
… replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the …
Page 1 of 2