Monte Carlo Modelling of an Orthovoltage X-ray System Using Multiple Applications in EGSnrc
Biodosimetry relies on calibration curves to convert biological damage induced by ionizing radiation to an absorbed dose. Health Canada generates these curves by irradiating biological samples with X-rays, though exposures scenarios could consist of other types of radiation which are challenging to …
-
Advancing an Open-Source Radiation Treatment Planning System for Orthovoltage X-ray and Cobalt-60 Teletherapy
… algorithms on a patient CT data set. Although orthovoltage x-ray beams remain a simple and effective low-cost treatment modality to treat superficial lesions, their treatment planning remains conventional. Additionally, Cobalt-60 (Co-60) technology continues to be the primary option in some …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
… field size for 6 different beam qualities in the orthovoltage x-ray range (100 kV tube potential 300 kV). The NE2571 ion chamber, Exradin A16 ion chamber, and Exradin W1 plastic scintillator were considered in this thesis. The last two detectors are not included in the TG-61 protocol.
-
Das langfristige klinische Outcome der Strahlentherapie bei der Behandlung der Plantarfasziitis
… course of RT. Of 396 patients irradiated on orthovoltage devices, 389 received 1.0 Gy (total dose 4.0 Gy), two received 0.5 Gy (total dose 6.0 Gy) and five received more than one series of RT with differing single doses. Three patients were irradiated on a linear accelerator and three were …
-
DEVELOPMENT OF A LOW-DOSE RADIATION THERAPY DEVICE FOR ACUTE RESPRITORY DISTRESS SYNDROME
… affects millions of people a year. The use of orthovoltage (200 – 500 keV) X-ray energy provides many advantages over traditional radiotherapy delivery with linear accelerators, such as low cost and greater accessibility. In addition, X-ray tubes have been shown throughout history to provide …
-
DEVELOPMENT OF A LOW-DOSE RADIATION THERAPY DEVICE FOR ACUTE RESPIRATORY DISTRESS SYNDROME
… illness affects millions of people a year. Using orthovoltage (200 – 500 keV) X-ray energy provides many advantages over traditional radiotherapy delivery with linear accelerators, such as low cost and greater accessibility. In addition, X-ray tubes have been shown throughout history to provide …
-
Design of an Ytterbium-169 brachytherapy source for gold nanoparticle-aided radiation therapy
… of external x-ray beams from a Philips RT-250 orthovoltage x-ray machine in an attempt to match the dosimetric characteristics of the Ytterbium-169 brachytherapy source. This investigation will enable the production of an external beam that can serve as a good surrogate of an actual …
-
HAFNIUM OXIDE-BASED NANOHETEROSTRUCTURES FOR CATALYTIC RADIOSENSITIZATION AND ENHANCED X-RAY RADIOTHERAPY
Orthovoltage X-ray beams are attractive for surface and intra-operative radiotherapy. Yet, their clinical utility is constrained by rapid attenuation and the limited dose that can be delivered without harming healthy tissue. High-Z hafnium oxide (HfO2) nanoparticles can boost local energy …
-
Development of instrumentation and techniques for preclinical image guided microirradiation
… This dosimeter allowed for more accurate orthovoltage beam characterization, thus improving treatment planning and translational treatments.
-
Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld
… are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; …
-
Development and Commissioning of An Independent Peer Review System For A Small Animal Irradiator
… to characterize other commercially available orthovoltage irradiators.
-
An X-ray Source Model and Characterization Method for Computing kV Radiation Dose
… a conventional CT scanner, superficial/orthovoltage therapy units, and to characterize an in-vivo film dosimetry program in our centre. Our technique is notable for relying only on empirical measurements. It allows a more accurate kV dose computation than treatment planning systems …
-
Θεραπεία διαβητικού ποδιού και ακτινικής δερματίτιδας σε καρκίνο του μαστού με εκχυλίσματα Ceratothoa oestroides και Pinus halepensis
… protocol was applied on mice, which received orthovoltage X-rays radiation at the Radiotherapy Department of the Hospital of Dermatology “Andreas Syggros”, Athens, Greece. The total dose of radiation was equivalent to the dose that breast cancer patients receive during radiotherapy. The mice …
-
Synthesis, Characterization, and Spectroscopy of Lanthanide-Doped Inorganic Nanocrystals; Radiant Flux and Absolute Quantum Yield Measurements of Upconversion Nanocrystals, and Fabrication of a Fiber-Optic Radiation Detector Utilizing Synthetically Optimized, Linearly Responsive Nanoscintillators
… image guided radiation therapy (IGRT) system, an orthovoltage cabinet-irradiator, and a clinical X-ray Computed Tomography (CT) machine. For all x-ray energies tested from 80 - 225 kVp, this near-radiotransparent device recorded scintillation intensities that tracked linearly with total radiation …
-
Development and Validation of Precision in Small Animal Radiotherapy Dose Monitoring
… dependence and the detector energy response in orthovoltage and megavolt (MV) x-rays. At temperatures between 5 and 46 C, the detector response fell within ±5% of the mean value. An appropriate, distance-based calibration methodology for MV x-rays that address the energy dependence of our …
-
Proof-of-Concept For Converging Beam Small Animal Irradiator
The Monte Carlo particle simulator TOPAS, the multiphysics solver COMSOL., and several analytical radiation transport methods were employed to perform an in-depth proof-ofconcept for a high dose rate, high precision converging beam small animal irradiation platform. In the first aim of this work, a …