Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"Oscilloscopes"”.
-
oscilografas mikrovaldiklio pagrindu /
… This work goal is to make microcontroller-based oscilloscopes, which have should waveform on the graphic display. Have additional functions for measuring direction voltage and signal to push the graphic display (up or down, expand or compress). With the oscilloscopes will be able to measure the …
-
Triggered Sweep Generators Using Modern Integrated Circuits
… Presently there are many relatively inexpensive oscilloscopes available, but triggered sweep capability is still reserved for those oscilloscopes costing more than 200 - 500 dollars. The goal of this project was to develop a respectably performing triggered sweep system at a low enough cost to …
-
Influence of source parameters on the properties of a plasma jet
… of an HP Vectra computer and three HP digital oscilloscopes. The program sets up the oscilloscopes to perform the measurements and then transfers the data to the computer for analysis. The resulting data are compared in order to better understand the optimum source arrangement for the Plasma …
-
Ανάπτυξη μεθοδολογίας λήψης και αποτίμησης χαοτικών σημάτων από μη-γραμμικά κυκλώματα για συστήματα τηλεπικοινωνιών
… all manufacturers of high performance digital oscilloscopes, since with proper design it does not affect the original acquired data. The basic difference of the implemented algorithm is the fact that while in high performance digital oscilloscopes the method is utilised in real time using DSP, …
-
Student Achievement and Affective Traits in Electrical Engineering Laboratories Using Traditional and Computer-Based Instrumentation
… while employing computer-based and traditional oscilloscopes. The students from two courses, electrical engineering for nonmajors and electronic fundamentals, were randomly assigned into treatment and comparison groups. The students' achievement and attitudes were gauged using assessment …
-
A Kerr Cell System for Measuring the Amplitude of High-Voltage Nonrecurring Pulses
… of low-voltage recording system. 2. High-voltage oscilloscopes with low sensitivity. 3. Sphere gaps with predetermined breakover voltages. Potential dividers of many types have been developed. These include resistive voltage dividers, capacitive voltage dividers, and combination resistive and …
-
Millimeter-wave Analog to Digital Converters: Technology Challenges and Architectures
… of the next generation high-speed sampling oscilloscopes. Meanwhile, data communication is the main driving force behind mm-wave data converter development. As with any mm-wave circuit, designers must go beyond simply relying on technology advancement to archives acceptable performance. …
-
Eye Diagram Assessment Platform for Fiber-Optic Communications
… Mostly eye-diagram analysis is done on high-end oscilloscopes or with LabView as a source-code; this research uses Flashy board (Pluto 3 and ADC) a small FPGA kit from a company called KNJN, for acquiring signals and then gives those signals to python for analysis. The main reason for considering …
-
Measuring picosecond flashover in pressurized sulfur hexafluoride (SF6)
… SF6 spark gap using D-dot sensors and oscilloscopes with analogue bandwidth ranging from 6 to 30 GHz. Results from a 50 GHz series sampling oscilloscope are also presented. Inter-electrode distance is varied between 0.1 and 0.9 mm and pressure is increased from 1 to 19 bar. Breakdown …
-
Audio Segmentation, Classification and Visualization
… with existing visualization methods such as oscilloscopes and spectrograms, both approaches yield more accessible illustrations of audio files and are more suitable for casual and non expert users.
-
Implementation of a CMOS 1 giga-sample/second analog waveform recorder
… experiments) and laboratory experimentation (oscilloscopes). The intended applications are very high-speed transient digitizers for use in adaptive equalizers and for monitoring inter-chip gigabit communications. These systems exploit the fact that slower ADCs are cheaper and more power …
-
A system for automatic positioning and alignment of fiber-tip interferometers
… photodiodes, motor-controlled tip/tilt stages, oscilloscopes, and a PCI card, constitute a closed-loop system with a feedback controller. The system is controlled by and communicates with a computer console using LabVIEW, a graphical language developed by National Instruments. Specifically, …
-
EXPERIMENTAL ACCURACY OF NILM LOAD DISAGGREGATION ON THREE-PHASE MICROGRID TEST BED
… analysis, the MPM data is compared against the oscilloscopes for accuracy. Validating the accuracy of the MPMs is a significant step in ensuring NILM is precisely executed, thereby bolstering the energy security of the United States Navy.
-
Real-Time Parallel Optical Sampling
… converters in electronic sampling oscilloscopes. The basic concept of parallel optical sampling is to split the signal into multiple branches where the branches are delayed with equidistant sampling times. The signal branches are then sampled in the optical domain with a pulse of a …
-
Development of Front-End Protection Circuit for TeBAT Nuclear Physics Research
… signal-to-noise ratio. Laboratory testing with oscilloscopes, pulsers, and microcontroller control will characterize system performance and verify reliability under high-voltage conditions. This work delivers a scalable, cost-effective interface that protects sensitive back-end electronics, …
-
Development of Front-End Protection Circuit for TeBAT Nuclear Physics Research
… signal-to-noise ratio. Laboratory testing with oscilloscopes, pulsers, and microcontroller control will characterize system performance and verify reliability under high-voltage conditions. This work delivers a scalable, cost-effective interface that protects sensitive back-end electronics, …
-
High Voltage Pulse Measurement System
… off the shelf pulse measurement systems such as oscilloscopes and multimeters cost thousands of dollars. Cheaper but simpler designs fail to provide isolation for safety. The measurement system in this thesis addresses all of these issues, allowing people to measure and characterize high voltage …
-
An ultrasonic velocity measurement system for verifying material properties
… with the majority of today's digital storage oscilloscopes (DSOs). Each algorithm uses a different technique or a variation of a similar technique for ascertaining the transit time of an ultrasonic pulse. Once the transit time is obtained, it is mathematically combined with the material …
-
Wideband direct conversion IQ modulators in indium phosphide DHBT technology
… (InP DHBT) (Low et al. 2005). The highest speed oscilloscopes that are currently available rely on InP DHBT circuits in their frontend and enable a combination of high peak-to-peak voltage and high sampling rate that is not possible using a silicon CMOS or silicon-germanium based frontend …
-
Integration and testing of a digital transceiver for a dual frequency, pulse-doppler radar
… signal generators, spectrum analyzers and oscilloscopes. The digital transceiver was able to function at pulse repetition rates exceeding 2 kHz, with a single transmit channel and three receive channels active. The lowpowered monostatic prototype system was constructed to test the digital …
Page 1 of 2