Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"Out-of-Step Protection"”.
-
Out-of-step Protection Using Energy Equilibrium Criterion in the Time Domain
… swings could be severe and it may lead to loss of synchronism among the interconnected generators. This is referred to as out-of-step condition. The voltage and current swings during an out-of-step condition damage power system equipments and also cause unwanted operations of various protective …
-
A fast method for out-of-step protection using state plane trajectories analysis
This thesis proposes a novel out-of-step protection technique using the state-plane representation of the generator speed and power angle. The critical clearing angle is computed using the principle that the total energy of the system at the instant the fault is cleared should be equal to the …
-
A predictive out-of-step protection scheme based on PMU enabled distributed dynamic state estimation
Recent widespread blackouts have indicated the need for more efficient and accurate power system monitoring, control and protection tools. Power system state estimation, which is the major tool that is used nowadays for providing the real-time model of the system, has significant biases resulting …
-
A new method of utilising stability study results in applying out-of-step protection to allow observability of rotor angle unstable conditions
… conditions may cause undesired operation of distance relays, resulting in the unnecessary switching of lines. To prevent the possible undesired operation of distance relays, a protection type known as out-of-step blocking is used. This protection type is complemented by another type of …
-
Synchronized Measurements And Applications During Power System Dynamics
… by prevailing system frequency. Some major blackouts in power systems are indeed featured with very large frequency disturbance. Quantitative study done in this dissertation shows that small frequency disturbance may lead to measurement errors, and large frequency disturbance may lead to wrong …
-
Setting transmission line out-of-step relays in complex power systems
… generator disconnections and rejection of large loads may result in a transient mismatch between the power generation and consumption that could lead to oscillations in the synchronous machine rotor angles. These oscillations, (referred to as power swings) can be damaging if they result …
-
Multiple Swing Out-of-Step Relaying
… to guarantee a continuous and reliable operation of the bulk interconnected system. The development of the synchronized Phasor Measurement technology, and its deployment in several locations in the network, has introduced a promising means to protect power systems from undesired conditions. This …
-
Power System Stability Analysis Using Wide Area Measurement System
… and post-mortem analysis tools to real-time protection and control at the systems level. Transient disturbances (such as lightning strikes) exist only for a fraction of a second but create transient stability issues and often trigger cascading type failures. The most common practice to …
-
Communication Infrastructure for the Smart Grid: A Co-Simulation Based Study on Techniques to Improve the Power Transmission System Functions with Efficient Data Networks
The vision of the smart grid is predicated upon pervasive use of modern digital communication techniques in today's power system. As wide area measurements and control techniques are being developed and deployed for a more resilient power system, the role of communication networks is becoming …
-
Transmission line protection in systems with high penetration of inverter-based resources (IBR)
Ever increasing integration of renewable resources into contemporary power systems has imposed a unique set of challenges for system protection. In the wake of several real-world incidents, effectiveness of techniques based on conventional system protection theory in protecting power systems with …
-
IEC 61850 BASED GOOSE AND SV SERVICES FOR WIDE-AREA PROTECTION AND AUTOMATION
… accurate estimations, and advanced protection functionalities in Smart Grid. IEC 61850 offers guidelines to implement publisher-subscriber based peer-to-peer communication framework within a substation, which is used to process measurement and control signals from bay level to …
-
Investigation of loss of synchronism phenomenon in synchronous machines and protection using trajectory of relative speed
The "loss of synchronism" condition in a synchronous machine is a critical state where the rotor fails to stay synchronized with the stator magnetic field. This can be caused by various factors, including system disturbances and power system instabilities. A machine undergoing a loss of synchronism …