Results 1 to 20 of 137 for “"Output Impedance"”
-
Output Impedance in PWM Buck Converter
… control that will reduce the closed-loop output impedance to match a specific transfer function. The transfer function for the compensator is rigorously developed. It is shown that a third-order compensator is sufficient to achieve a closed-loop output impedance represented by a …
-
Hybrid Active Power Filter with Output Impedance Control
… regulation at high frequencies by increasing the output impedance beyond a desired level. This dilemma has been recognized and several topologies have been proposed to overcome this problem. One category is improved passive devices, with the latest involving array capacitors to achieve near-zero …
-
Analysis of the Output Impedance from Switched DC/DC Converters
… the PuLS is redesigned to be able to measure output impedance of switched DC/DC converters by drawing a sinusoidally shaped current while measuring the output voltage ripple. Existing measurement methods are investigated, the theoretical output impedance of a buck converter is calculated and …
-
Output Impedance Modeling and Measurement of a 28 kW Synchronous Generator
… and in the end, the small-signal d-q impedance model for the SM has been verified by simulations and experiments in the Center for Electronics Systems (CPES) at Virginia Tech. The impedance measurement unit (IMU) was built by CPES. It is designed for measuring three-phase AC power …
-
Design of a 3.3 V analog video line driver with controlled output impedance
… is an amplifier that provides the necessary output current to drive the low impedance of the line. The main requirements for design are high output swing, high linearity, matched impedance to the line and power efficiency. These requirements are addressed by a class AB amplifier whose output …
-
Uncertainty and disturbance estimator design to shape and reduce the output impedance of inverter
… a passive filter is installed at the inverter output. This generates high output impedance which limits the inverter ability to maintain high power quality at the inverter output. This thesis deals with an impedance shaping approach to the design of power inverter control. The Uncertainty and …
-
High output resistance current drive circuits for medical applications
… the analysis, design and development of high output impedance current drive circuits for medical applications. These circuits are used in medical systems such as Electrical Impedance Tomography (EIT) imaging. The target specification for EIT was an output impedance in excess of 1MΩ at 1MHz. …
-
Isolating Power Amplifiers for Parallel Transmit MRI
… existing MRI systems. Current Source and Low Output Impedance amplifiers were built and compared in terms of theory of operation, their ability to isolate array coils, and the amount of power they can deliver to a coil. The current source amplifiers function by introducing a high impedance in …
-
Input filter compensation for switching regulators
… of transient response, audiosusceptibility and output impedance characteristics. These problems are caused mainly by the interaction between the peaking of the output impedance of the input filter and the regulator control loop. Conventional single-stage and two-stage input filters can be …
-
Static and dynamic nonlinearity compensation techniques for high performance current-steering digital-to-analog converters
… effect, code and voltage dependence of finite output impedance, nonlinear settling time, charge injection, and switch timing errors. In this thesis, two nonlinearity compensation techniques are presented to improve the overall performance of the current-steering DACs.</p> <p>The first design …
-
Out-of-Loop Compensation Method for Op-Amps Driving Heavy Capacitive Loads
… of an ideal one, particularly those of gain and output impedance. When presented with a capacitive load, such as a MOSFET or ADC, feedback in an op-amp circuit can quickly become unstable. This thesis studies and characterizes an op-amp’s output impedance and how its interaction with this type of …
-
Dynamic Performance Analyses of Current Sharing Control for DC/DC Converters
… distributed power systems. To ensure balanced output currents among paralleled power modules, current sharing control is usually necessary.Active current sharing controls with current feedback mechanism are widely used in today's power supplies. However, the dynamic performance of these current …
-
Photovoltaic Source Simulators for Solar Power Conditioning Systems: Design Optimization, Modeling, and Control
… (ii) fast transient response-time, (iii) output impedance matching with actual PV generator, and (iv) precise reference generation technique. Throughout this research, two different PV source simulator systems are designed, modeled, and experimentally verified. The design of the first …
-
Analysis and synthesis of series damper actuator
… a kind of force control actuator with high output force fidelity and low output impedance. A novel force/torque control actuator called Series Damper Actuator (SDA) was proposed. The proposed SDA system incorporated a series damper between the actuator and the load. The system was designed …
-
Droop Control of Parallel-Operated Inverters
… operation of inverters with different types of output impedance, the power sharing, the voltage and frequency regulation, as well as the current limiting.
-
Improved Models for DC-DC Converters
… part of this system. If the load current and the output voltage are measured there are good possibilities to obtain a good model of the load on-line. Adaptive control can then be applied to improve the control. In peak current-mode control, the output voltage and the inductor current are measured …
-
Controlador de histéresis de bajo coste para convertidos buck síncrono multifase
… functions for powering such demanding loads: output voltage regulation, adaptive voltage positioning, current sharing and phase interleaving. Nor is there a design methodology based on the closed-loop output impedance. This design would optimize the output voltage transient response and, in …
-
High Performance Digital Control Techniques for Powering Microprocessors
… technique to naturally implement the desired output impedance is proposed. In this technique, Adaptive Voltage Positioning (AVP) is implemented by generating a dynamic voltage reference and a dynamic current reference to achieve the desired output impedance. A dual-voltage-loop control with …
-
DC-DC Converters - Dynamic Model Design and Experimental Verification
… part of this system. If the load current and the output voltage are measured there are good possibilities to obtain a good model of the load on-line. Adaptive control can then be applied to improve the control. In peak current-mode control, the output voltage and the inductor current are measured …
Page 1 of 7