Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Output factors"”.

  1. A Comparison of Small Field Output Factors for Stereotactic Radiation Therapy

    … application of newly published small-field output factors (OPFs) for the AcurosXB 15.6 (AXB) algorithm in Varian’s Eclipse treatment planning system (TPS). The primary goal is to validate the extended AXB (AXBe) model’s accuracy in calculating dose for small-field geometries, which are known …

    gatech Repository record for A Comparison of Small Field Output Factors for Stereotactic Radiation Therapy (opens in a new tab)

  2. Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning

    … of percent depth dose (PDD), beam profiles, and output factors across a wide range of field sizes. Conventional commissioning workflows often require multiple detectors and can be time-intensive, particularly for small-field dosimetry where measurement accuracy is highly sensitive to detector …

    vcu Repository record for Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning (opens in a new tab)

  3. Small field dose measurements with Gafchromic film

    … and a Sun Nuclear Edge Detector (diode). Output factors were calculated for each detector and compared for accuracy. The output factors were measured from a Varian Clinac iX, Clinac 21EX, Trilogy, and TrueBeam; as well as a Novalis Tx. The outputs from different machines at different …

    gatech Repository record for Small field dose measurements with Gafchromic film (opens in a new tab)

  4. Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation

    … of the TPS, such as depth doses, dose profiles, output factors in air and in water, etc. In this work, an investigation has been made of different methods of measuring output factors in air. An investigation on the variability of the prescribed characterisation measurements among several users …

    lund Repository record for Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation (opens in a new tab) Download PDF for Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation (opens in a new tab)

  5. Comprehensive Investigation of Energy Fluence Spectra and MLC Modeling Parameters and their Effects on Dose Calculation Accuracy in Pinnacle

    … shows a slight better calculation of the output factor. The MLC model parameters were also investigated, however, adjusting the MLC offset table was found to give significant improvements, especially for the small field geometries.</p> <p>The full impact of adjusting the photon energy …

    mcmaster Repository record for Comprehensive Investigation of Energy Fluence Spectra and MLC Modeling Parameters and their Effects on Dose Calculation Accuracy in Pinnacle (opens in a new tab)

  6. Dosimetric evaluation and verification of treatment planning systems

    … ratio model to calculate the dose. Measured output factors (OF) and head scatter factors (HSF) for several square fields, fields formed by independent jaws, MLC formed fields and blocked fields were determined and compared with OFs and HSFs predicted by the TPSs. OR for virtual wedges, formed …

    manitoba Repository record for Dosimetric evaluation and verification of treatment planning systems (opens in a new tab)

  7. First-generation College Students: Their Use of Academic Support Programs and the Perceived Benefit

    … Survey also examined input, environment and output factors of academically successful first-generation and academically successful non-first-generation students. Again, both groups indicated similar responses to the questions asked. First-generation college students in this study were …

    unt Repository record for First-generation College Students: Their Use of Academic Support Programs and the Perceived Benefit (opens in a new tab)

  8. Dosimetric properties of a prototype high field parallel MRI-Linac

    … correction factor to be applied during dose output measurements. Chapter 3 reviews the literature and provides recommendations to the Australasian College of Physical Scientists in Medicine for determination of dose on MRI-linacs. Recommendations include: specifying ion chambers and their …

    unsw Repository record for Dosimetric properties of a prototype high field parallel MRI-Linac (opens in a new tab)

  9. Connecting Access and Efficiency: Community College Course-Taking Patterns That Predict Vertical Transfer

    … variables related to the input, process, and output factors of institutional performance. to connect access and efficiency, this study linked student course-taking variables to institutional performance outcomes. The conceptual framework fused resource dependence and choice overload theories …

    wm-mary Repository record for Connecting Access and Efficiency: Community College Course-Taking Patterns That Predict Vertical Transfer (opens in a new tab)

  10. Asymmetric collimation : dosimetric characteristics, treatment planning algorithm, and clinical applications

    … produces non-trivial alterations in absolute output, depth dose and beam profile. The full potential of asymmetric collimation can only be realized with a proper treatment planning algorithm specific for asymmetric collimation. In this thesis the dosimetric characteristics of asymmetric fields …

    ubc Repository record for Asymmetric collimation : dosimetric characteristics, treatment planning algorithm, and clinical applications (opens in a new tab) Download PDF for Asymmetric collimation : dosimetric characteristics, treatment planning algorithm, and clinical applications (opens in a new tab)

  11. Total factor productivity of tropical soybean-maize systems: the case of the safrinha crop system in Mato Grosso, Brazil

    … of this research is to analyze the input and output factors driving total factor productivity. Total factor productivity takes into consideration all of agricultural inputs (land, labor, fertilizer, seed, pesticide, diesel, and machinery) used in the production of soybean and second maize …

    uiuc Repository record for Total factor productivity of tropical soybean-maize systems: the case of the safrinha crop system in Mato Grosso, Brazil (opens in a new tab)

  12. Improving waiting times in the Emergency Department

    … providers delivering care for a single patient. Factors that have been shown to delay care in the ED have been broken down into input factors such as triaging, throughput factors during the visit, and output factors, which include discharge planning and available inpatient beds for admitted …

    bu Repository record for Improving waiting times in the Emergency Department (opens in a new tab)

  13. Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator

    … (PVDR), collimator factor (CF), and relative output factor (OF) were carried out for 2 cm x 2 cm, 3 cm x 3 cm, 4 cm x 4 cm, and 5 cm x 5 cm mini-beam collimated 6 MV fields on each linear accelerator. As well, Monte Carlo simulation of the mini-beam collimated fields were used to link the …

    sask Repository record for Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator (opens in a new tab)

  14. Merger, Efficiency, and Productivity in the US Credit Union Industry

    … the inefficiencies (slacks) of the input and output factors for the period 2007-2019. First, we estimate the Malmquist Productivity Index (MPI) of the US credit unions; results reveal that both acquired and acquiring credit unions benefit from mergers. However, acquired credit unions benefit …

    uno Repository record for Merger, Efficiency, and Productivity in the US Credit Union Industry (opens in a new tab)

  15. Δοσιμετρία ασύμμετρων και μικρών πεδίων γραμμικού επιταχυντή και κλινικές εφαρμογές στην απεικονιστικώς καθοδηγούμενη στερεοτακτική ακτινοθεραπεία

    … stereotactic radiotherapy system (Cyberknife). Output factors and physical characteristics of small fields were measured with various detectors i.e. pinpoint ionization chamber shielded diode radiochromic EBT films and polymer gels. The clinical accuracy of the image guided robotic stereotactic …

    greece Repository record for Δοσιμετρία ασύμμετρων και μικρών πεδίων γραμμικού επιταχυντή και κλινικές εφαρμογές στην απεικονιστικώς καθοδηγούμενη στερεοτακτική ακτινοθεραπεία (opens in a new tab)

  16. Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator

    … (e.g. PDD and off-axis ratios). Subsequently, output factors for various square and circular applicators were measured using different dosimeters (ionization chamber, radiochromic film) and compared with MC simulations. The standard gamma index method with AAPM TG 53 recommendations are used to …

    utswmed Repository record for Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator (opens in a new tab)

  17. Organic fibre-based arrays for proton radiotherapy applications

    … at multiple depths to observe beam penumbrae, output factors and depth-dose. We found through comparison to ionisation chambers and radiochromic film that the array is capable of measurements accurate to within 8% in the centre of proton beams, and within 2% at 3.5 cm depth in water with …

    ubc Repository record for Organic fibre-based arrays for proton radiotherapy applications (opens in a new tab) Download PDF for Organic fibre-based arrays for proton radiotherapy applications (opens in a new tab)

  18. The Development of a Growth Platform Model for Small to Medium Sized Knowledge Based Firms

    … by developing a new model that details the factors that influence firm growth, how these factors develop over time, how and why they influence the firm and to what level they need to be developed to in order for growth to occur. The research adds to the firm growth literature through the …

    southwales Repository record for The Development of a Growth Platform Model for Small to Medium Sized Knowledge Based Firms (opens in a new tab) Download PDF for The Development of a Growth Platform Model for Small to Medium Sized Knowledge Based Firms (opens in a new tab)

Page 1 of 2