Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 88 for “"Overcurrent Protection"”

  1. Design and Implementation of Overcurrent Protection Relays Test Bench

    … employed electromechanical and microprocessor protection relays, manual isolation and industrial circuit breakers, switches, variable autotransformer (VARIAC), voltmeters and ammeters. During the dismantling, a lot of equipment was retrieved for future possible use. This led to the idea of …

    wvu Repository record for Design and Implementation of Overcurrent Protection Relays Test Bench (opens in a new tab)

  2. Relay in the loop test procedures for adaptive overcurrent protection

    … with distributed generators have changed how protection and control systems are designed. Protection systems in conventional U.S. distribution systems are radial with the assumption that current flows always from the utility source to the end user. However, in a microgrid with distributed …

    ksu Repository record for Relay in the loop test procedures for adaptive overcurrent protection (opens in a new tab)

  3. Data analytics applications to fault locations and overcurrent protection devices

    … with their locations (fault analytics) and (2) overcurrent protection devices installed in the system (device analytics). The fault analytics module is used to identify fault events among other power quality events and estimates the location to the fault occurring in the system. The proposed …

    texas Repository record for Data analytics applications to fault locations and overcurrent protection devices (opens in a new tab)

  4. Evaluation of overcurrent protection performance and application on the Eskom shunt capacitors during system disturbances.

    … report began as an investigation into an overcurrent relay protection operation on a shunt capacitor bank (SCB) at ESKOM’s Westgate substation. Westgate substation has two SCBs, both of which were in service at the time of the 2007 incident. However, only the overcurrent protection scheme …

    ukzn Repository record for Evaluation of overcurrent protection performance and application on the Eskom shunt capacitors during system disturbances. (opens in a new tab)

  5. Active, Controllable Overvoltage and Overcurrent Protection Devices for Power Systems with High Inverter-Based Resource Domination

    … significant challenges to modern power system protection devices. For OCP, the fault current magnitude is significantly limited and variable due to the inherent current limiting of inverters and the diversity of IBR connectivity during a fault. As a result, OCP devices must intelligently detect …

    gatech Repository record for Active, Controllable Overvoltage and Overcurrent Protection Devices for Power Systems with High Inverter-Based Resource Domination (opens in a new tab)

  6. A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution Systems with Distributed Generations

    … BPFs may cause unwanted tripping of existing overcurrent (OC) protection devices and result in permanent outages for a large number of customers. This thesis presents a protection approach that modified an existing overcurrent protection scheme to reduce the number of customers affected by …

    tamu Repository record for A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution Systems with Distributed Generations (opens in a new tab)

  7. A New Approach to Mitigate the Impact of Distributed Generation on the Overcurrent Protection Scheme of Radial Distribution Feeders

    … feeders is becoming a common trend. The existing Overcurrent Protection (OCP) scheme on such feeders consists mainly of overcurrent protection devices (OCPDs) such as fuses and reclosers. When DG is placed on the remote end of a 3-phase lateral, the radial configuration of the feeder is lost. As a …

    tamu Repository record for A New Approach to Mitigate the Impact of Distributed Generation on the Overcurrent Protection Scheme of Radial Distribution Feeders (opens in a new tab)

  8. High Power Density and Overcurrent Protection Challenges in the Design of a Three-Phase Voltage Source Inverter for Motor Drive Applications

    … designed, built, and tested. In addition a novel overcurrent protection residing in the inverter dc link is proposed in response to the concern of using normally-on devices in voltage source inverters. Successful hardware validation of both the VSI and the overcurrent protection circuit is …

    vt Repository record for High Power Density and Overcurrent Protection Challenges in the Design of a Three-Phase Voltage Source Inverter for Motor Drive Applications (opens in a new tab)

  9. An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation

    … systems and the major philosophies of their protection, namely, selectivity and sensitivity, were easily achieved. Settings for overcurrent protective devices (OCPDs) were static and based on the maximum load downstream of its location, with little concern of major configuration changes. …

    tamu Repository record for An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation (opens in a new tab)

  10. Proteção de sobrecorrente direcional utilizando transformada wavelet

    Traditionally, the primary protection used in low voltage power systems, as distribution systems, is the overcurrent protection due to its simplicity and low cost. However, in these recent years, the number of distributed generation connected to the system has been growing, which changes the …

    brazil-ufrn Repository record for Proteção de sobrecorrente direcional utilizando transformada wavelet (opens in a new tab)

  11. Impacts of Solar Photovoltaic on the Protection System of Distribution Networks - A case of the CIGRE low voltage network and a typical medium voltage distribution network in Sweden

    … flow from the supply to the customer end. Overcurrent protection coordination for passive radial networks is based upon single direction power flow. When distributed generation (DG) is present in these networks, the current flows from the customer end as well. This current flow distorts the …

    chalmers Repository record for Impacts of Solar Photovoltaic on the Protection System of Distribution Networks - A case of the CIGRE low voltage network and a typical medium voltage distribution network in Sweden (opens in a new tab)

  12. Validation of Results of Smart Grid Protection through Self-Healing

    … is a verification of the results of “Smart Grid Protection through Self-Healing” from the publication of Chathurika Chandraratne, et al., that proposes a protection solution for the smart grid. The paper used as reference has as the main focus on three different protections; directional …

    usf Repository record for Validation of Results of Smart Grid Protection through Self-Healing (opens in a new tab)

  13. DC microgrid protection

    … they still face a significant challenge in protection. That is due to the feature of DC fault with no zero-crossing point, and there is no standard for protection. Thus, it is essential for DC microgrid to detect faults timely and have a comprehensive protection scheme to ensure the system …

    unsw Repository record for DC microgrid protection (opens in a new tab)

  14. Protection system lab experiments with overcurrent and differential relays

    … the theory and application of two ubiquitous protection schemes, overcurrent protection and differential current protection, with the design of experiments and exercises for electrical engineering students. The objective of this undertaking is educational, so that students can learn, …

    texas Repository record for Protection system lab experiments with overcurrent and differential relays (opens in a new tab)

  15. Edge-of-grid voltage control in distribution networks

    … issues related to voltage regulation and system protection are arising. In this scenario, advanced voltage regulation technologies that provide voltage control at the grid-edge, that is at the low-voltage secondary side of the distribution circuit, have emerged as a potential solution to address …

    texas Repository record for Edge-of-grid voltage control in distribution networks (opens in a new tab)

  16. Adaptive protection solutions for future active power distribution networks

    … in this dissertation is to investigate the protection challenges that this evolution will introduce to the functions of protecting distribution networks, to develop new solutions and implement and demonstrate them in the laboratory. To analyse the potential problems that may be introduced to …

    strathclyde Repository record for Adaptive protection solutions for future active power distribution networks (opens in a new tab)

  17. DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY

    Distance protection schemes are widely used for the protection of high voltage transmission lines. This form of protection is of the high speed and can provide both primary and back-up facilities in a single scheme. To meet the rapid development of the power systems and the large amount of the …

    nus Repository record for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab)

  18. Application of distance protection for transformers in Eskom transmission.

    … (HV) Inverse Definite Minimum Time (IDMT) overcurrent protection and Medium Voltage (MV) IDMT overcurrent protection are employed to provide backup for these transformer’s differential protection and for uncleared through faults. Eskom’s Transmission setting philosophy states “that the HV …

    ukzn Repository record for Application of distance protection for transformers in Eskom transmission. (opens in a new tab)

Page 1 of 5