Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Overcurrent relay"”.

  1. DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY

    … at the beginning of this thesis. Distance relay using symmetrical components approach is one of the well established distance protection schemes. After a thorough analysis of the previously suggested algorithms, a combined algorithm of symmetrical components and compensation current scheme …

    nus Repository record for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab) Download file for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab)

  2. Application of evolutionary algorithms for optimal directional overcurrent relay coordination

    Relay coordination is necessary to ensure that while protection relays operate as fast as possible, they are also able to isolate only the faulted parts of the system from the network, ensuring that a power system disturbance does not result in interruption of the power supply to a larger part of …

    cape-town Repository record for Application of evolutionary algorithms for optimal directional overcurrent relay coordination (opens in a new tab)

  3. THE DESIGN AND IMPLEMENTATION OF A VERSATILE MICROPROCESSOR-BASED DIRECTIONAL OVERCURRENT RELAY

    Due to advancements in the field of electronics, relay designers are able to implement practical microprocessor-based relay designs which are being used more and more by utilities. With the increasing number of digital overcurrent relays being developed for use in electrical power systems need has …

    sask Repository record for THE DESIGN AND IMPLEMENTATION OF A VERSATILE MICROPROCESSOR-BASED DIRECTIONAL OVERCURRENT RELAY (opens in a new tab)

  4. Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment

    … sources and impact on the coordination of relays. The impact of different levels of photovoltaic (PV) penetration on the protective device coordination in a microgrid has been studied in detail. A medium voltage distribution network is modelled and simulated using ETAP and several case …

    umkc Repository record for Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment (opens in a new tab)

  5. OVERCURRENT RELAYS: MODELLING OF CHARACTERISTICS AND FEASIBILITY OF A COMPUTER BASED DESIGN

    Overcurrent relays are used to protect sub-transmission and distribution lines from phase to phase and phase to ground faults. The procedures of determining the settings of these relays include the rule of thumb, template and digital computer methods. The relay characteristics are defined by lookup …

    sask Repository record for OVERCURRENT RELAYS: MODELLING OF CHARACTERISTICS AND FEASIBILITY OF A COMPUTER BASED DESIGN (opens in a new tab)

  6. Relay coordination with multiple breaker-in/breaker-out stations on the transmission line

    … the difficulty of setting up the zone distance relays and overcurrent relays when multiple breaker-in/breaker-out stations are added on the transmission line. It explains how many breakers can safely be added without compromising the zone 2 time delay of 50 cycles (limit imposed by TVA), how to …

    utc Repository record for Relay coordination with multiple breaker-in/breaker-out stations on the transmission line (opens in a new tab)

  7. A MICROPROCESSOR-BASED SYSTEM FOR PROTECTION OF POWER TRANSFORMERS

    Differential, overcurrent and ground fault relays are used for protecting transformers in electric. power systems. Several algorithms, that perform these functions and are suitable for implementation on microprocessors, have been proposed in the past. This thesis describes and evaluates an improved …

    sask Repository record for A MICROPROCESSOR-BASED SYSTEM FOR PROTECTION OF POWER TRANSFORMERS (opens in a new tab)

  8. Optimum coordination of directional overcurrent relays in a distribution network with distributed generation

    The conventional relay protection coordination method is mainly used in the industry to calculate the protective overcurrent relay settings. The conventional method requires many inputs and does not produce the best relay coordination results. When there are multiple sources, the calculation …

    nwu-za Repository record for Optimum coordination of directional overcurrent relays in a distribution network with distributed generation (opens in a new tab)

  9. A study of the effect of harmonics in the system on the performance of residual current-operated circuit-breakers and electromechanical overcurrent relays

    … Consequently, RCCBs as well as other protection relays are subject to non-sinusoidal current waveforms. Recent studies showed that RCCBs are greatly affected by harmonics, however the reasons for this are not clear. A literature search has also shown that there are inconsistencies in the analysis …

    aston Download PDF for A study of the effect of harmonics in the system on the performance of residual current-operated circuit-breakers and electromechanical overcurrent relays (opens in a new tab)

  10. An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation

    … sensitivity, were easily achieved. Settings for overcurrent protective devices (OCPDs) were static and based on the maximum load downstream of its location, with little concern of major configuration changes. However, the integration of distribution generators (DGs) in radial distributions …

    tamu Repository record for An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation (opens in a new tab)

  11. Protection and Disturbance Mitigation of Next Generation Shipboard Power Systems

    … controller that improves upon a directional AC overcurrent relay protection system is proposed offering additional protection discrimination between faults and pulsed-power Load (PPL) in MVDC systems. The controller is designed to segregate between system dynamic short-circuit fault and bus …

    odu Repository record for Protection and Disturbance Mitigation of Next Generation Shipboard Power Systems (opens in a new tab)

  12. Improving the safety operation of three-phase shunt active filter

    … transients. The main protection devices used are overcurrent relay and metal oxide varistor. Furthermore, a control circuit of voltage phase sequence detection and grid frequency deviation are also investigated and presented in this thesis. Finally, the shunt active filter operation is analyzed …

    ets-quebec Download PDF for Improving the safety operation of three-phase shunt active filter (opens in a new tab)

  13. Control and operation of MMC-HVDC system for connecting offshore wind farm

    … meantime, enable satisfactory operation of the overcurrent protection relays. Considering the requirements of overcurrent relay, a fault current providing control for the offshore MMC is proposed which ramps up current during faults over a predefined profile.;This ensures adequate fault current …

    strathclyde Repository record for Control and operation of MMC-HVDC system for connecting offshore wind farm (opens in a new tab)

  14. Protection of distribution networks with distributed generation

    … tripping, reduction in reach of a distance relay, lack of detection of single-phase to ground (1LG) fault with ungrounded utility side interconnection transformer configuration and failure of a fuse saving scheme. In respect of the case study, practical and effective solutions that rely on …

    soton Download PDF for Protection of distribution networks with distributed generation (opens in a new tab)

  15. Power system optimization and healthcare optimization

    … work. In Stochastic Optimization for Discrete Overcurrent Relay Tripping Characteristics and Coordination, there is a relay in each node to protect the power system. When the relay detects a fault current, it operates for a certain amount of time before it opens up. We need to decide the …

    texas Repository record for Power system optimization and healthcare optimization (opens in a new tab)

  16. Modelling of a protective scheme for AC 330 kV transmission line in Nigeria

    … intelligent devices, such as protective relays and communication systems, to enable rapid and accurate fault identification and isolation. First, a 330 kV, 500 km three-phase Delta transmission line is modelled using MATLAB/SIMULINK. A section of the Delta network in Delta State Nigeria …

    glasgow Repository record for Modelling of a protective scheme for AC 330 kV transmission line in Nigeria (opens in a new tab) Download PDF for Modelling of a protective scheme for AC 330 kV transmission line in Nigeria (opens in a new tab)

  17. Protection system lab experiments with overcurrent and differential relays

    … of two ubiquitous protection schemes, overcurrent protection and differential current protection, with the design of experiments and exercises for electrical engineering students. The objective of this undertaking is educational, so that students can learn, understand, and execute …

    texas Repository record for Protection system lab experiments with overcurrent and differential relays (opens in a new tab)

  18. Validation of Results of Smart Grid Protection through Self-Healing

    … on three different protections; directional overcurrent protection, overcurrent protection, and transformer protection, which are validated through ETAP software simulation of IEEE- 9 bus and 14 bus electrical power systems, the same used by the author. It was validated after repeated …

    usf Repository record for Validation of Results of Smart Grid Protection through Self-Healing (opens in a new tab)

  19. Intelligent Protection Schemes for Smart Grids

    … their current magnitudes are below traditional overcurrent relay pickups. Most of HIFs include igniting arc between a conductor and a ground surface that may cause fire and human safety issues. Therefore, in this dissertation, HIF detection is extensively evaluated in the real distribution …

    unr Repository record for Intelligent Protection Schemes for Smart Grids (opens in a new tab)

Page 1 of 2