Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"Overhead electric lines"”.

  1. An Aerodynamic Investigation of the Causes of Overhead Electrical Transmission Line Gallop

    Overhead electrical transmission lines vibrate due to the action of a prevailing wind. These cable vibrations can be classified into two categories— high-frequency and low-frequency. The high-frequency vibrations, "aeolian" vibrations or "singing wires," is a low-amplitude phenomenon. It has been …

    byu Repository record for An Aerodynamic Investigation of the Causes of Overhead Electrical Transmission Line Gallop (opens in a new tab) Download PDF for An Aerodynamic Investigation of the Causes of Overhead Electrical Transmission Line Gallop (opens in a new tab)

  2. Ground line moment analysis of body extended 161kV transmission towers

    This study simplified the analysis required for the extension of a single circuit tangent 161kV transmission tower. The parameters were modified and modern criteria used to evaluate the tangent tower with various body extensions. The basis of analysis for the extended lattice towers compared the …

    utc Repository record for Ground line moment analysis of body extended 161kV transmission towers (opens in a new tab)

  3. The application of active control in railway pantographs

    Pantographs are essential elements of modern electric trains, coupling the train to the overhead electric lines in order to deliver a continuous supply of electrical energy to the vehicle. Undesired contact can cause excessive wear and poor train operation performance. In the worst case, this can …

    birmingham Download PDF for The application of active control in railway pantographs (opens in a new tab)

  4. Extra high voltage transmission corridor siting: technical, public, institutional and regulatory considerations

    … the siting study process. - Development of guidelines for improved EHV transmission corridor siting studies. The principal methodology of the research is the single case study of Wyoming-Cloverdale 765 kV siting project, which represents a model of a contemporary, interstate, EHV siting study. …

    vt Repository record for Extra high voltage transmission corridor siting: technical, public, institutional and regulatory considerations (opens in a new tab)

  5. Nondestructive health assessment of ACSR transmission lines, The

    Includes bibliographical references (pages 92-102).

    colo-mines Repository record for Nondestructive health assessment of ACSR transmission lines, The (opens in a new tab)

  6. Dynamic gust response factors for transmission line structures

    … structures used for distribution of electricity. Dynamic wind loads on these structures result from two components: wind loads on the tower and wind loads on the conductors. Various approaches are available for the calculation of the gust response factor. The Gust response factor …

    ttu Repository record for Dynamic gust response factors for transmission line structures (opens in a new tab)

  7. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line

    … effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage …

    portland-state Repository record for Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line (opens in a new tab)