Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 89 for “"Overhead lines"”.

  1. Lightning surge propagation in overhead lines and gas insulated bus-ducts and cables

    … of lightning surge propagation in overhead multi-phase untransposed transmission lines was analysed first. Modal analysis, together with special rotation techniques to fit time domain solutions were then used to simulate the wave propagation in multi-phase untransposed line in an …

    ubc Repository record for Lightning surge propagation in overhead lines and gas insulated bus-ducts and cables (opens in a new tab) Download PDF for Lightning surge propagation in overhead lines and gas insulated bus-ducts and cables (opens in a new tab)

  2. Wave propagation characteristics and computation improvements for transients on finite-length overhead lines

    This thesis first describes the derivation of the impedance and admittance of an infinitely long conductor line and a finite-length conductor line over the earth with finite resistivity. Then, the impedance, admittance, propagation constant (attenuation and velocity), and characteristic impedance …

    manitoba Repository record for Wave propagation characteristics and computation improvements for transients on finite-length overhead lines (opens in a new tab)

  3. The improved use of auto-reclosing on overhead-lines in the Dutch high voltage grid

    The goal of this paper is to give more insight in which Auto-Reclosing (AR) methods, including smart AR methods, can be used in different parts of the Dutch High Voltage (HV) (110-380kV) grid regulated by TenneT TSO. Next to that the most appropriate AR method will be recommended for each of …

    eindhoven Repository record for The improved use of auto-reclosing on overhead-lines in the Dutch high voltage grid (opens in a new tab)

  4. Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation

    … can cause flashovers on Medium Voltage (MV) lines from both direct and nearby strikes. The work presented in this dissertation thoroughly investigates the characteristics of lightning-initiated flashover faults, expected overvoltage stress and the performance of different surge protection …

    aalto Repository record for Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation (opens in a new tab)

  5. Influence of Ground Electrical Properties on Lightning-Electromagnetic Fields for Wind Farms and Overhead Lines - Applications of the FDTD Method

    … where lightning-induced voltages (LIVs) on overhead lines have been investigated due to nearby return strokes on the ground. The 3rd and 4th tasks are related to direct lightning problems where the electromagnetic fields have been studied due to direct stroke to a grounding system and a …

    aalto Repository record for Influence of Ground Electrical Properties on Lightning-Electromagnetic Fields for Wind Farms and Overhead Lines - Applications of the FDTD Method (opens in a new tab)

  6. Technical consideration and impact of converting overhead power lines to underground power cables

    In the modern era, overhead transmission lines become irrelevant in the development of new cities as underground cables become mandatory. Nonetheless, it is crucial to understand overhead line technology in order to model the next generation of power networks, as most of the power networks still …

    vu-aus Download PDF for Technical consideration and impact of converting overhead power lines to underground power cables (opens in a new tab)

  7. Line fault location in emerging HVDC transmission systems

    … high voltage direct current (HVDC) transmission lines and cables is based on the travelling-wave principle. This technology has served well for the conventional point-to-point HVDC systems, but is inadequate to handle emerging HVDC transmission configurations such as schemes with very long …

    manitoba Repository record for Line fault location in emerging HVDC transmission systems (opens in a new tab)

  8. Δυναμική ηλεκτροθερμική ανάλυση συστημάτων μεταφοράς ηλεκτρικής ενέργειας

    … systems and more specifically the AAC and ACSR overhead lines, as well as underground cables. Also, a very basic part of this PhD thesis is the calculation of temperature fluctuations due to its continuous load variations and the delay time in which they are noticed. Initially, the dynamic …

    greece Repository record for Δυναμική ηλεκτροθερμική ανάλυση συστημάτων μεταφοράς ηλεκτρικής ενέργειας (opens in a new tab)

  9. Water Tree Analysis and On-Line Detection Algorithm Using Time Domain Relectometry

    With the increasing amount of overhead lines being converted to underground cables in the distribution system, the need to be able to determine the health of these underground cables becomes imperative. Since the health of underground cables cannot be determined by visual means like overhead lines, …

    clemson Repository record for Water Tree Analysis and On-Line Detection Algorithm Using Time Domain Relectometry (opens in a new tab)

  10. Ανάπτυξη στοχαστικού μοντέλου σύλληψης κεραυνού και εφαρμογές του σε συστήματα αντικεραυνικής προστασίας

    … configurations as well as HVDC and HVAC overhead lines. These methodologies take into account the lightning activity at the location under examination and are combined with electromagnetic transient simulations in ATP-EMTP software to compute the critical currents causing flashover of …

    greece Repository record for Ανάπτυξη στοχαστικού μοντέλου σύλληψης κεραυνού και εφαρμογές του σε συστήματα αντικεραυνικής προστασίας (opens in a new tab)

  11. Harmonic/Transient analysis of the RARIK distribution network

    … has RARIK been systematically phasing out all overhead lines and replacing them with underground cables. Now 70% of the distribution grid of RARIK are underground cables. RARIK has noticed that the number of damaged electronics being reported to them, due to events in their grid has increased …

    reykjavik Repository record for Harmonic/Transient analysis of the RARIK distribution network (opens in a new tab)

  12. Full-space conformal mapping for the calculation of the parameters of overhead transmission lines and underground cables

    … per-unit-length electrical parameters of a given overhead transmission line or underground cable in an unbounded space considering the effect of the ground. This is achieved using a two-dimensional conformal mapping technique, which consists of a modified bilinear transformation to map a semi-open …

    manitoba Repository record for Full-space conformal mapping for the calculation of the parameters of overhead transmission lines and underground cables (opens in a new tab)

  13. Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines

    In Finland, covered-conductor (CC) overhead lines are commonly used in medium voltage (MV) networks because the loads are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees which produce partial discharges (PDs) in CC lines. This thesis presents a …

    aalto Repository record for Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines (opens in a new tab)

Page 1 of 5