Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 62 for “"Overstrength"”.
-
Robustness and overstrength of structures under impacts
… consequences. In this methodology, the role of overstrength in a robustness-oriented design is considered (Chapter 5).
-
Evaluation of Overstrength Factors for Partially-Restrained Steel Frames
Overstrength and response modification factors are commonly used in seismic codes/specifications to establish lateral loads that simulate earthquake loading. Overstrength of partially-restrained non-composite steel frames has not been thoroughly studied within the context of seismic design. …
-
Overstrength and ductility of reinforced concrete shear-wall frame buildings not designed for seismic loads
The overstrength and ductility have been investigated for two typical reinforced concrete shear wall frame buildings using nonlinear pushover analysis. One is a 16 story slab block and the other is a 25 story point block. The structures are designed in accordance to British Standard BS 8110, which …
-
Behaviour of bolted end-plate connections for glulam braces under cyclic axial loads
… Code of Canada (NBCC) provides ductility and overstrength factors for glulam braced frames and directs designers to Canadian Standards Association (CSA) O86, to design glulam braces to achieve adequate levels of ductility and overstrength. However, CSA O86 lacks the detailed design …
-
Seismic response of diagonally reinforced slender coupling beams
… as ductility capacity, stiffness degradation, overstrength and energy dissipation capability. A finite element analysis was performed to study the axial restraint parameter mentioned above and assess the degree of restraint given by the slab to the coupling beam. Parameters such as the slab …
-
An evaluation of minimum flexural reinforcement in concrete girders with an emphasis on post-tensioned segmental members
… LRFD Bridge Specifications (2017).</p> <p>The overstrength moment ratio required through the AASHTO LRFD Bridge Specifications (2017) has been clarified, which allows for an adequacy evaluation for minimally reinforced girders. Through the experiments, it is shown that the full-scale girders …
-
SIMULATION AND PERFORMANCE OF STEEL SHEET SHEATHED SHEAR WALLS IN CFS-FRAMED BUILDING SYSTEMS
… 700 individual tests. It is utilized to evidence overstrength in CFS-framed steel sheet sheathed shear wall (line)s. More efficient overstrength values are proposed. The proposed simulation tools are employed to provide key performance parameters including overstrength. The experiments and …
-
Analytical Development of Capacity Design Factors for a Precast Concrete Diaphragm Seismic Design Methodology
… (flexural) strength, termed "shear reinforcement overstrength", to promote a ductile mechanism in precast diaphragms. The performance of precast diaphragms with different shear reinforcement overstrength is examined. Appropriate shear reinforcement overstrength design factors are proposed to …
-
Predicted Inelastic Response of Conventional and Ductile Steel Concentrically Braced Frame Buildings Under Wind Loads
… pushover analysis was used to determine system overstrength and ductility under wind loads. Eigenvalue vibration analysis was used to determine the building periods of vibration and their mode shapes. Nonlinear dynamic dynamic response history analysis was used to determine the wind collapse …
-
Inelastic Behavior of Three-Story Buildings with Concrete-Filled Composite Plate Shear Walls Subjected to Wind Loads
… wind load profile to determine the static system overstrength. Incremental nonlinear dynamic response history analyses are run using wind loads derived from wind tunnel test data to determine the wind collapse safety. The results from the static analyses show that the coupled shear walls have …
-
Experimental Tests of Wide Aspect Ratio Cross Laminated Timber – Steel Diaphragms for Hybrid Building Applications
… all configurations compared to the required overstrength of 2.8. Due to the large overstrength, the diaphragm can be expected to remain elastic at design forces. Across the ASD design range, the configuration that included metal surface splines with screws had the highest stiffness followed …
-
Assessment of seismic force modification factors for conventional construction reinforced concrete shear wall structures in Canada using the performance-based unified procedure
… such as ductility-related factors (Rd) and overstrength-related factors (Ro), with values of 1.5 and 1.3 for conventional construction concrete shear walls, respectively. Values for these parameters are largely based on engineering judgment without a systematic calculation. To address this, …
-
Seismic design and behaviour of coupled balloon-type cross-laminated timber shear walls with high-performance screwed connections
… using numerical models, achieving a system overstrength of 1.7 to 2.0, depending on the wall height. Finally, incremental dynamic analysis was used to validate the proposed seismic force modification factors. Using guidance from FEMA P-695 and the performance-based unified assessment …
-
Predicted Strength and Ductility of Roof Truss Diaphragms with Tension-Only Rod Bracing and Hillside Washer Rod Connections
… effect. From the subassembly model, predicted overstrength and ductility factors were found to range from 1.33 to 1.44 and 2.00 to 2.92 respectively. The calculated ductility factors were found to match the predicted ductility values. However, the overstrength factors varied from the predicted …
-
Seismic Analysis of and Provisions for Dry-Stack Concrete Masonry Wall Systems with Surface Bond in Low-Rise Buildings
… including the force reduction factor, overstrength factor, and the displacement amplification factor. To determine these factors the guidelines from the Federal Emergency Management Agency (FEMA) Quantification of Building Seismic Performance Factors 2009 were followed. The guidelines …
-
Development and Testing of New Ring Spring Self-Centering Energy Dissipative (RS-SCED) Braces for Seismic Resilience of Buildings and Bridges
… seismic design procedures rely on ductility and overstrength factors for simplified seismic analysis and design using an equivalent static force procedure. In this study, the FEMA P695 methodology is used to determine the ductility (R), overstrength (Ω_0) and deflection amplification (C_d) …
-
Seismic Performance Assessment of Reinforced Masonry Core Walls with Boundary Elements
… performance of RM structures. The ductility and overstrength of the proposed system are quantified using nonlinear pushover analysis following FEMA P695 guidelines, and incremental dynamic analysis (IDA) is used to assess seismic collapse risk and to develop system-level-based fragility curves. …
-
Improving the Performance of Reinforced Concrete Beam-Column Joints Designed for Seismic Resistance
… the first part of the thesis that the flexural overstrength factor should be the same irrespective of whether Grade 300E or Grade 500E longitudinal reinforcement is used in a beam. This finding contradicts current New Zealand practice, which specifies a higher flexural overstrength factor for …
-
Αντισεισμικός σχεδιασμός γεφυρών σκυροδέματος με βάση τις μετακινήσεις
… to the expected seismic performance - the global overstrength of the bridges which are designed with the proposed procedure is practically equivalent to the global overstrength of the conventionally designed bridges (current force-based design). The step by step description of the design algorithm …
-
Multihazard Performance-Based Assessment of Multi-Storey Steel Braced Frame Buildings
… level, neither accounts for the inherent system overstrength. In other words, it does not explore the wind response of the lateral force resisting system (LFRS) from yielding to the system’s failure mechanism. For a building located in a seismic region, the LFRS has well-detailed ductile fusses …
Page 1 of 4