Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"Oxinium"”.

  1. Nanomechanical property characterization of femoral head materials

    … include Cobalt-Chromium-Molybdenum alloy, Oxinium, Tetragonal Zirconia Polycrystal, Stabilized Magnesia, Zirconia Toughened Alumina and Alumina. Nanoindentation was performed to examine the hardness and elastic modulus of all six materials at three different loads. Nanoscratch and Nanowear …

    missouri Repository record for Nanomechanical property characterization of femoral head materials (opens in a new tab)

  2. Vliv povrchu umělé kloubní jamky na součinitel tření

    … hlavic (CoCrMo, BIOLOX Delta, BIOLOX Forte, oxinium) a tři typy maziv (PBS, modelová synoviální kapalina a roztok kyseliny hyaluronové). Z naměřených výsledků vyplývá, že při použití PBS a synoviální kapaliny došlo ke snížení součinitele tření u modifikované jamky. Lze tedy předpokládat, že …

    brno-tech Repository record for Vliv povrchu umělé kloubní jamky na součinitel tření (opens in a new tab)

  3. Studium tření kyčelních kloubních náhrad s modifikací topografie povrchu

    … jamky a tři hladké hlavice (keramika, kov, oxinium). Výsledky s použitím synoviální kapaliny ukazují, že texturovaný povrch jamky má pozitivní vliv na snížení tření a stabilizaci hodnot. Nejvýraznější poklesy jsou pozorovány při použití jamky s menšími důlky, ta například spolu s keramickou …

    brno-tech Repository record for Studium tření kyčelních kloubních náhrad s modifikací topografie povrchu (opens in a new tab)

  4. Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions

    … CoCrMo, zirconium nitride (ZrN)coated, and Oxinium knee implants were intentionally damaged by electrocautery from both Bovie and Aquamantys sources by a three second hover method. Bovie electrocautery damage was done at 30W, 45W, and 60W. Aquamantys electrocautery damage was done at 140W, …

    tenn-hsc Repository record for Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions (opens in a new tab)

  5. Iatrogenic Electrocautery Damage and Cellular-Based Corrosion of Total Joint Arthroplasty Biomaterials

    … compared to the MP for all bearing surfaces. The Oxinium surface displayed the greatest increase in roughness parameters compared to the undamaged regions. The CoCr surface displayed the greatest Rsk for the BP damaged areas. The ZrN had the smallest differences in Rz and Ra for both MP and BP …

    tenn-hsc Repository record for Iatrogenic Electrocautery Damage and Cellular-Based Corrosion of Total Joint Arthroplasty Biomaterials (opens in a new tab)

  6. Προοπτική συγκριτική τυχαιοποιημένη μελέτη αποτελεσματικότητας των τεχνικών χειρουργικών τομών περιορισμένης επεμβατικότητας

    … laminar airflow theatre, and the Genesis II Oxinium prosthesis (Smith & Nephew) was used for all patients. Modern cementing technique was used for the fixation of both components. The patella was not replaced; All patients had patient-controlled epidural analgesia for 48 hours …

    greece Repository record for Προοπτική συγκριτική τυχαιοποιημένη μελέτη αποτελεσματικότητας των τεχνικών χειρουργικών τομών περιορισμένης επεμβατικότητας (opens in a new tab)