A THERMODYNAMIC STUDY ON CARBURIZING OF PLAIN CARBON AND ALLOY STEELS (OXYGEN PROBE)
… to be about the same for a given temperature and oxygen partial pressure, regardless of differences in chemical composition.
-
OXIDATION OF NITRITE IONS AND CHLORINE-CONTAINING COMPOUNDS BY POTASSIUM FERRATE(VI)
… was also monitored using a calibrated dissolved oxygen probe. A selective nitrate electrode was used to potentiometrically determine product formation. The overall reaction was determined to be mixed-order with a hydronium ion dependency of 0.58. The rate of the reaction was also shown to depend …
-
Use of recirculation reactor to study biodegradation of 2-chlorophenol
… vs. non-buffered defined medium. Dissolved oxygen concentration was monitored using a flow Clark-type dissolved oxygen probe. Oxygen consumption was correlated with the biodegradation of 2-chlorophenol. Physical removal of 2-chlorophenol by air stripping in the absence of microorganisms was …
-
Thermodynamics of the Fe-V-O System
… 1550-1700ºC using H₂O/H₂ equilibrium and/or an oxygen probe. 1st and 2nd order interaction parameters between V and O were determined, and the deoxidation reactions occurring when V is used as a deoxidizer were studied. Deoxidation diagrams are presented for V concentrations up to 12 wt. %. </p> …
-
Thermodynamics of the Fe-V-O System
… 1550-1700ºC using H₂O/H₂ equilibrium and/or an oxygen probe. 1st and 2nd order interaction parameters between V and O were determined, and the deoxidation reactions occurring when V is used as a deoxidizer were studied. Deoxidation diagrams are presented for V concentrations up to 12 wt. %. </p> …
-
Use of recirculation reactor to study biodegradation of Aroclor 1242, a polychlorinated biphenyl
… of Aroclor 1242 in aqueous phase. Dissolved oxygen concentration was monitored using a flow Clark-type dissolved oxygen probe. Oxygen consumption was compared to the biodegradation of Aroclor 1242. Physical removal of Aroclor 1242 by adhering to the system without microorganisms was also …
-
Pentachlorophenol and oxygen consumption of immobilized mixed bacterial culture
… of Pentachlorophenol (PCP) concentration on oxygen consumption of immobilized microbial cells. The microbial population, from a municipal wastewater treatment plant, was immobilized in calcium alginate gel. The following studies have also been conducted in this project: Comparison of the …
-
Biodegradation of styrene in a recirculation reactor using immobilized activated sludge
… closed system using dilute H_2O_2 solution as an oxygen source. The process parameters studied were as follows: Effect of flow rate of recycle stream, Effect of biomass loading, Effect of spiking concentration of styrene, and Flow pattern and average residence time within the reactor. Dissolved …
-
Development of a sensor-based rapid microbial testing platform for the Irish meat industry
… food company (Dawn Meats), several new optical oxygen sensor based systems were devised to increase efficiency and accuracy of testing. Chapter 1 (Literature review) describes the state of the art in the area, the range of existing approaches and analytical systems, and their capabilities. …
-
Optical oxygen sensing based on ruthenium and porphyrin complexes
… design and performance of a ruggedised dissolved oxygen probe, both in the laboratory and in the field, are reported. This probe is based on phase fluorometric detection of the quenched fluorescence of an oxygen-sensitive ruthenium complex. Dissolved oxygen probes have a number of different …
-
Gas flow hydrodynamics in an oxygen delignification retention tower
… column ( L/D = 4.1:1) using a dissolved oxygen probe. The main results of these experiments are as follows. First is was found that at medium pulp consistency, there are no bubbles formed in the tower due to the lack o f free water. Second, at pulp consistencies higher than 5 %, gas is …
-
Gas hydrodynamics and mass transfer in low- and medium-consistency pulp suspensions in a retention tower
… column in batch-operation using a dissolved oxygen probe. Experimental results were comparable to that in literature for water and for pulp fibre suspensions having Cm < 2%. The presence of fibres had a significant effect on the gas holdup and mass transfer characteristic with results …
-
Tissue Oxygen Imaging for Non-invasive Metastasis Detection
… evidence demonstrating significantly reduced oxygen in metastatic nodes, non-invasive oxygen imaging may improve metastasis detection while avoiding surgical morbidities.This thesis explores the application of a novel oxygen imaging method called Photoacoustic Lifetime Imaging (PALI) for early …
-
A Study of the Heterogeneous Electron Transfer and Dioxygen Binding Reactions of Myoglobin
… of the electrode surface, and the removal of dioxygen from the sample solution. A formal heterogeneous electron transfer rate constant, k0′, of 2.6 (±0.5) x 10-5 cm/s and a transfer coefficient, α, of 0.48 (±0.05) were obtained using SPS/CA. These results are shown to correlate well with those …
-
SENSING CHARACTERISTICS AND MATHEMATICAL MODELLING OF PLANT TISSUE POLYPHENOLASE SENSORS
… sensor was prepared by overlaying a dissolved oxygen probe with a biofilm containing pretreated tissue powder of apple, potato, banana or mushroom. During the pretreatment, the tissue was fragmented, exposed to air, washed with water, vacuum dried and pulverised to a fine powder. These sensors …
-
A Role For Reactive Oxygen Species In Photodynamic Therapy
… the photosensitizer was transferred to dissolved oxygen to form singlet oxygen. This product has a very brief half-life and will cause cellular damage only in the immediate vicinity of its formation. But an excited-state photosensitizer can also interact with oxygen to form superoxide anion …
-
ELECTROCHEMICAL MICROBIAL SENSOR FOR RAPID BIOCHEMICAL OXYGEN DEMAND MEASUREMENT
… sensor for rapid determination of biochemical oxygen demand of wastewaters was developed by coupling a dissolved oxygen probe with a biofilm, containing immobilized Bacillus subtilis and Bacillus licheniformis 7B, and a cross-linked poly(4-vinylpyridine) film. Both steady state and initial rate …