Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 133 for “"Oxygen sensor"”.

  1. Development of an optical dissolved oxygen sensor

    A dissolved oxygen sensor based on fluorescence quenching of the oxygen-sensitive ruthenium complex, [Ru(II)-tris(4,7-diphenyl-1,10-phenanthroline]2+, which has been immobilised in a porous silica sol-gel-derived film, is reported. Ormosil sensing films are fabricated using the modified silica …

    dcu Download PDF for Development of an optical dissolved oxygen sensor (opens in a new tab)

  2. Optimization of polymer/ruthenium complex optical oxygen sensor

    This thesis is focused on developing an optical oxygen sensor, to detect oxygen content in sealed packages. The oxygen sensor material was developed using tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride, a well known oxygen sensitive dye. The [Ru(Ph2Phen)3](Cl) 2 dye was incorporated …

    unlv Repository record for Optimization of polymer/ruthenium complex optical oxygen sensor (opens in a new tab) Download PDF for Optimization of polymer/ruthenium complex optical oxygen sensor (opens in a new tab)

  3. Development of a dissolved oxygen sensor for marine applications

    A dissolved oxygen sensor based on the fluorescence intensity quenching of a ruthenium dye complex, [Ru(II)-tris(4,7-diphenyl-l,10-phenanthroline)]2+, which has been entrapped in a porous sol-gel film, is reported. The aim of the project was to develop and test a portable instrument (prototype), …

    dcu Download PDF for Development of a dissolved oxygen sensor for marine applications (opens in a new tab)

  4. Novel luminescent oxygen sensor systems for smart food packaging

    For industrial applications, solid-state O2 sensors based on the quenching of photoluminescence, should be accurate, robust, easy-to-use in a calibration-free manner. These sensors generally consist of an O2 sensitive luminescent dye in a polymer matrix. The properties of this matrix such as dye …

    cork Repository record for Novel luminescent oxygen sensor systems for smart food packaging (opens in a new tab)

  5. Development of an optical sol-gel-based dissolved oxygen sensor

    A dissolved oxygen sensor based on the quenching of fluorescence from a ruthenium dye complex entrapped in a porous sol-gel film is reported. Sol-gelderived silica films were fabricated by dip-coating onto planar and optical fibre substrates. The films were pre-doped with oxygen-sensitive ruthenium …

    dcu Download PDF for Development of an optical sol-gel-based dissolved oxygen sensor (opens in a new tab)

  6. Instrumentation of YSZ oxygen sensor calibration in lead-bismuth eutectic

    … on the accurate measurement and control of the oxygen concentration (tens of ppb levels) in the liquid LBE. An Oxygen Sensor Calibration/Measurement Apparatus is designed and built to deliberately calibrate the Yttria Stabilized Zirconia (YSZ) oxygen sensor. A detailed description of this system …

    unlv Repository record for Instrumentation of YSZ oxygen sensor calibration in lead-bismuth eutectic (opens in a new tab) Download PDF for Instrumentation of YSZ oxygen sensor calibration in lead-bismuth eutectic (opens in a new tab)

  7. Development of a reusuable atomic oxygen sensor using oxide thick films

    … aim of this project was to develop a thick film sensor made of zinc oxide that would accurately respond to various fluxes of atomic oxygen (AO), allowing it to be regenerated after saturation. The sensors were manufactured using a thick film technique of screen printing over a substrate (alumina) …

    soton Download PDF for Development of a reusuable atomic oxygen sensor using oxide thick films (opens in a new tab)

  8. Design of a fiber optic oxygen sensor based on immobilized hemoglobin

    The fiber optic Oxygen sensor consists of a thin layer of immobilized deoxyhemoglobin at the common end of a bifurcated fiber. Immobilization is done using the alginate gel procedure. The immobilized reagent is separated from the standard oxygen sample by the gel with or without semi-permeable …

    njit Repository record for Design of a fiber optic oxygen sensor based on immobilized hemoglobin (opens in a new tab)

  9. Wireless and untethered electrochemical oxygen sensor for respiratory gas exchange analysis

    … of this work is to create a novel medical sensor for monitoring the concentration of oxygen in exhaled human breath. The ultimate goal is to combine this work with a contiguous research project to deliver a sensor that measures several breath constituents, including CO2, and end-tidal …

    umn Repository record for Wireless and untethered electrochemical oxygen sensor for respiratory gas exchange analysis (opens in a new tab)

  10. Design and Evaluation of an Ultrasonic Oxygen Sensor for Medical Ventilators

    … it is also necessary to be able to add extra oxygen to the breathable air meaning it must be possible to measure the oxygen concentration in the ventilator. Right now, the most commonly used sensors for this purpose are electrochemical sensors that are expensive, have slow response-times, not …

    chalmers Repository record for Design and Evaluation of an Ultrasonic Oxygen Sensor for Medical Ventilators (opens in a new tab)

  11. A fibre optic oxygen sensor based on the fluorescence quenching of ruthenium compounds

    Oxygen quenching of long lifetime fluorescent dyes takes place when the excited state of the fluorescent dye decays non-radiatively to the ground state by energy transfer to the oxygen. Thus, by monitoring the intensity of fluorescence, the oxygen dependence is seen as a decrease in intensity for …

    dcu Download PDF for A fibre optic oxygen sensor based on the fluorescence quenching of ruthenium compounds (opens in a new tab)

  12. Instrumental Aspects of Oxygen Sensing: Quantitation and Recalibration of a Biofouled Oxygen Sensor

    In vivo oxygen sensing is a critical area of research for medical applications, such as ischemic stroke, but this important topic is not fully understood or resolved. In addition, the best method for calibration of in vivo sensors is as yet undetermined. For all implantable devices, biofouling, the …

    arkansas Repository record for Instrumental Aspects of Oxygen Sensing: Quantitation and Recalibration of a Biofouled Oxygen Sensor (opens in a new tab)

  13. Oxygen reduction at microelectrodes : application to the dissolved oxygen sensor for in situ oceanographic measurements

    … accurate and reliable electrochemical dissolved oxygen sensor for oceanographic measurements. The amperometric response of the sensor gives direct information on the concentration of dissolved oxygen, which is reduced at a microdisc cathode to peroxide species and water. A number of parameters …

    soton Download PDF for Oxygen reduction at microelectrodes : application to the dissolved oxygen sensor for in situ oceanographic measurements (opens in a new tab)

  14. Aeration studies in submerged fermentations using a steam-sterilizable dissolved oxygen sensor of improved design

    … because of the unavailability of adequate oxygen sensing equipment. A steam-sterilizable oxygen sensor of improved design was developed out of an investigation of several potential sensors. This rapidly responding galvanic probe made use of a lead anode, a silver cathode, an acetate buffer …

    must-thes Repository record for Aeration studies in submerged fermentations using a steam-sterilizable dissolved oxygen sensor of improved design (opens in a new tab)

  15. The endothelial oxygen sensor PHD2 as a central regulator of hematopoietic system and its niche

    … verfolgt, dass eine Veränderung der Sauerstoffsensorik in Endothelzellen eine Modifizierung der Aktivität hämatopoetischer Stammzellen ermöglicht. Material und Methoden: Trotz des Wissens um die Bedeutung von Sauerstoff für die Endothelzellen fehlt uns das Verständnis dafür, wie die …

    qucosa-diss

  16. Characterisation of porosity and sensor response times of sol-gel-derived thin films for oxygen sensor applications

    The ability to determine oxygen concentration is of great importance in many industrial, environmental and medical applications. In recent years, a range of sol-gelderived optical oxygen sensors, for measuring oxygen in both gas and aqueous phase has been developed, in which the oxygen sensitive …

    dcu Download PDF for Characterisation of porosity and sensor response times of sol-gel-derived thin films for oxygen sensor applications (opens in a new tab)

  17. The Oxygen Sensor Hif-Prolyl Hydroxylase-2 (Phd2) Is a prominent regulator of the Neutrophil Inflammatory Response

    … hydroxylase domain proteins (PHD1-3). These oxygen-sensors directly regulate the HIF-activity and orchestrate numerous physiological as well as pathological processes. Actually, a considerable amount of studies have shown that HIFs can directly control the innate and adaptive immune response …

    qucosa-diss

  18. The Development Of Mems-Based Implantable Oxygen Sensing Systems

    Oxygen-based cues are direct assessments for a wide range of in vivo biological effects, ranging from mitochondrial disease to tissue engineering/regenerative medicine. Existing electrochemical oxygen sensors are permanent systems applicable to short-term intraoperative use; devices are extracted …

    penn Repository record for The Development Of Mems-Based Implantable Oxygen Sensing Systems (opens in a new tab)

  19. The Development and Biocompatibility of Low Temperature Co-Fired Ceramic (LTCC) for Microfluidic and Biosensor Applications

    … One proposed application is the evaluation of oxygen tension and oxidative stress in perfusion cell culture and bioreactors. A Clark-type oxygen sensor is successfully integrated with LTCC technique in this work. In the current work, a solid state proton conductive electrolyte is used to …

    uky-thes Repository record for The Development and Biocompatibility of Low Temperature Co-Fired Ceramic (LTCC) for Microfluidic and Biosensor Applications (opens in a new tab)

Page 1 of 7