Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Oxygen--Measurement."”.

  1. Oxygen measurement in the Labrador Sea

    … was to analyze the annual cycle of dissolved oxygen (O2) in the central Labrador Sea on the basis of oxygen data observed by autonomous profiling floats during the period September 2003 and August 2006. The Labrador Sea in one of just a few regions where open-ocean deep winter convecion occurs …

    cau-kiel Repository record for Oxygen measurement in the Labrador Sea (opens in a new tab)

  2. Atmospheric singlet molecular oxygen : measurement techniques and excited state oxidant production

    Singlet molecular oxygen (¹O₂*) is the first excited state of molecular oxygen (O₂) and is formed through indirect photochemistry during irradiation of atmospheric brown carbon. ¹O₂* acts as a competitive oxidant to OH radicals, ozone, hydrogen peroxide, and superoxide in the photochemical …

    ubc Repository record for Atmospheric singlet molecular oxygen : measurement techniques and excited state oxidant production (opens in a new tab) Download PDF for Atmospheric singlet molecular oxygen : measurement techniques and excited state oxidant production (opens in a new tab)

  3. Oxygen Measurement During Cell Culture: From Multiwell Plates to Microfluidic Devices

    Oxygen is an important regulator of normal cell behavior. Proper supply of oxygen is required to maintain ATP production, while perturbation of oxygen supply alters cell behavior and leads to tissue damage and cell death. <italic>In vivo</italic>, cells are exposed to a mean partial pressure of …

    maryland Repository record for Oxygen Measurement During Cell Culture: From Multiwell Plates to Microfluidic Devices (opens in a new tab)

  4. Computer controlled oxygen bioreactor

    A computer controlled oxygen bioreactor has been designed to obtain more accurate values for oxygen bioreactor requirements and to optimize oxygen productivity with respect to oxygen concentration. This study solves a specific problem relating to oxygen concentration measurement and bioreactor …

    njit Repository record for Computer controlled oxygen bioreactor (opens in a new tab)

  5. High-resolution measurement of dissolved oxygen concentration in vivo using two-photon microscopy

    Because oxygen is vital to the metabolic processes of all eukaryotic cells, a detailed understanding of its transport and consumption is of great interest to researchers. Existing methods of quantifying oxygen delivery and consumption are non-ideal for in vivo measurements. They either lack the …

    texas Repository record for High-resolution measurement of dissolved oxygen concentration in vivo using two-photon microscopy (opens in a new tab)

  6. Progress Towards Development of a Desktop Oxygen Scanner for Assessing Macroencapsulated Islet Oxygenation

    … treatment for diabetes, yet providing adequate oxygenation to transplanted, encapsulated islets remains a major challenge because: 1) the islets require a specific level of oxygen (pO2) - both too little and too much oxygen impairs islet functionality and viability; 2) it is challenging to make …

    umn Repository record for Progress Towards Development of a Desktop Oxygen Scanner for Assessing Macroencapsulated Islet Oxygenation (opens in a new tab)

  7. Photosynthesis by Natural Phytoplankton Populations and Its Interrelationship With Light and Temperature

    <p>Photosynthesis measurements were conducted through the fall, winter and spring of 1974-75 on natural phytoplankton populations from Coote's Paradise (Lake Ontario). Oxygen evolution was measured using oxygen electrodes under a matrix of light and temperature conditions. Respiration was also …

    mcmaster Repository record for Photosynthesis by Natural Phytoplankton Populations and Its Interrelationship With Light and Temperature (opens in a new tab)

  8. Improving heating plant emissions using flue gas carbon monoxide monitoring : a thesis presented in partial fulfilment of the requirements for the degree of Masters of Engineering in Automation and Control at Massey University

    … a combination of carbon monoxide monitoring and oxygen trim control to automatically adjust the excess air setpoint. Heating plants require the correct amount of oxygen for combustion. Too little excess air does not allow complete combustion, producing a loss in efficiency and wasted fuel. Too …

    massey Repository record for Improving heating plant emissions using flue gas carbon monoxide monitoring : a thesis presented in partial fulfilment of the requirements for the degree of Masters of Engineering in Automation and Control at Massey University (opens in a new tab)

  9. The adaptive response of cardiovascular-pulmonary patients to nursing measures as reflected by mixed venous oxygen saturation measurements

    … artery catheters, the effect of position and preoxygenation on mixed venous oxygen saturation and select hemodynamic parameters was examined. A convenience sample was randomly assigned by a coin flip to experimental or control groups. Hemodynamic parameters were compared with the mixed venous …

    twu Repository record for The adaptive response of cardiovascular-pulmonary patients to nursing measures as reflected by mixed venous oxygen saturation measurements (opens in a new tab)

  10. Extremum-Seeking Control of Industrial-Scale Fermentation Processes

    … of the frequency spectrum of the dissolved oxygen measurement following a periodic perturbation in the feed rate. A controller based on this strategy was tested in pilot scale, where it gave higher specific growth rates and lower concentrations of overflow metabolites during the exponential …

    lund Repository record for Extremum-Seeking Control of Industrial-Scale Fermentation Processes (opens in a new tab) Download PDF for Extremum-Seeking Control of Industrial-Scale Fermentation Processes (opens in a new tab)

  11. Open, stirred-jar technique for estimation of microbial deoxygenation in the prediction of dissolved oxygen profiles in streams

    … stirred-jar technique as a method to estimate oxygen-uptake due to degradation of organic waste and nitrification by suspended microbes was studied. With this procedure, both the concentration of waste and the reaeration rate can be set to values similar to those expected in the stream. Thus, …

    vt Repository record for Open, stirred-jar technique for estimation of microbial deoxygenation in the prediction of dissolved oxygen profiles in streams (opens in a new tab)

  12. A Study of Oxygen Precipitation in Heavily Doped Silicon

    Gettering of impurities with oxygen precipitates is widely used during the fabrication of semiconductors to improve the performance and yield of the devices. Since the effectiveness of the gettering process is largely dependent on the initial interstitial oxygen concentration, accurate measurements …

    portland-state Repository record for A Study of Oxygen Precipitation in Heavily Doped Silicon (opens in a new tab)

  13. Biomedical sensor for transcutaneous oxygen measurements using thick film technology

    The measurement of the partial pressure of oxygen in arterial blood is essential for the analysis of a patient's respiratory condition. There are several commercially available methods and systems to measure this parameter transcutaneously. However, they tend to be cumbersome and costly. To …

    soton Download PDF for Biomedical sensor for transcutaneous oxygen measurements using thick film technology (opens in a new tab)

  14. Neural Basis of Functional Connectivity MRI

    … relies on temporal correlation in at-rest blood oxygen level dependent (BOLD) fluctuations. Thus, understanding the neural origin of at-rest BOLD correlation is of critical significance. By shedding light on the origin of the large-scale brain organization captured by fcMRI, it will guide the …

    wustl Repository record for Neural Basis of Functional Connectivity MRI (opens in a new tab)

  15. Mammary Window Chamber Model: A Platform For Multi-Modality Cancer Imaging And Dynamic Oxygenation Assessment

    … on cancer development and treatment. Current oxygenation assessment methods for longitudinally following spatially resolved oxygen changes over time are lacking. The development and testing of an oxygen sensitive porphyrin coating used in conjunction with the mammary window chamber model is …

    arizona-thes Repository record for Mammary Window Chamber Model: A Platform For Multi-Modality Cancer Imaging And Dynamic Oxygenation Assessment (opens in a new tab)

  16. Electrochemical microsensor system for cell culture monitoring

    … microsensor systems is a marker-free, continuous measurement technique of chemical and physical parameters in cell culture, which impacts many different areas of biological research. With the focus being on eukaryotic cells, many fields such as standardisation of cell culture, cancer research, …

    freiburg-diss Repository record for Electrochemical microsensor system for cell culture monitoring (opens in a new tab)

  17. Oxygen and the ovarian follicle : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Bioprocess Engineering at Massey University, Palmerston North, New Zealand

    The role oxygen plays in the developing ovarian follicle is of interest not only to the field of developmental biology but also to in-vitro fertilisation (IVF) technologists, as oxygenation of the oocyte is considered to be a potential determinant of oocyte competence. Oxygen transport through the …

    massey Repository record for Oxygen and the ovarian follicle : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Bioprocess Engineering at Massey University, Palmerston North, New Zealand (opens in a new tab)

  18. QUANTITATIVE, SPATIAL IMAGING BASED MEASUREMENTS TO ASSESS CELLULAR HEALTH AND OXYGENATION IN A TISSUE ENGINEERED TEST SYSTEM

    … develop the corresponding quantitative, spatial measurement methods of cell behavior and viability. Optical widefield microscopy was selected as a measurement tool because of its ease of use, wide availability, and inherent large-scale spatial measurement capacity. Digital image analysis and …

    clemson Repository record for QUANTITATIVE, SPATIAL IMAGING BASED MEASUREMENTS TO ASSESS CELLULAR HEALTH AND OXYGENATION IN A TISSUE ENGINEERED TEST SYSTEM (opens in a new tab)

Page 1 of 2