  1. An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip

    … electroosmotic flow (EOF) in a microfluidic chip. EOF is a naturally occurring phenomenon at the fluid-surface interface in microfluidic chips when an electric field is applied across the fluid. When isoelectric focusing (IEF) is carried out to separate proteins based on their surface charge, …

    calpoly Repository record for An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip (opens in a new tab)

  2. Microfluidic device for the generation and replication of DNA microarrays and the label-free detection of biomolecular interactions on these arrays

    … phase PCR from NGS (next generation sequencing) chips, but neither replications of this DNA arrays could be generated nor where the used surfaces suitable for high- throughput label-free screening.<br>To generate multiple replicates in combination with label-free measurements, first a PDMS based, …

    freiburg-diss Repository record for Microfluidic device for the generation and replication of DNA microarrays and the label-free detection of biomolecular interactions on these arrays (opens in a new tab)

  3. OUTPUT POWER OPTIMIZATION OF MICROBIAL FUEL CELLS BY SCALABLE MICROFLUIDIC DEVICES

    … Microbial Fuel Cells (BMFC). A microfluidic chip-based BMFC was designed to evaluate bacterial electricity at microscale distances. The system could be used to optimize biological parameters, geometry, and electrode scaling towards increased power. The polydimethylsiloxane (PDMS) chip is …

    nps Repository record for OUTPUT POWER OPTIMIZATION OF MICROBIAL FUEL CELLS BY SCALABLE MICROFLUIDIC DEVICES (opens in a new tab)

  4. Development of Smartphone dual-laser waveguide based fluorescent microscopy system using 3D printing

    … the optical microscopy technology along with a PDMS chip. Hence, this integrated novel innovation which prioritizes accuracy and the ease of usage, can be a game changer for patients who live in countries of limited resources and can moreover aid to the impoverished people who are in dire need …

    ku Repository record for Development of Smartphone dual-laser waveguide based fluorescent microscopy system using 3D printing (opens in a new tab)

  5. A microfluidic sensing system for simultaneous monitoring of extracellular Ca(II) and insulin secretion

    … and inexpensive. Polydimethylsiloxane (PDMS) chip was then designed, fabricated and characterised to be capable of immobilising the biological tissues and manipulating their extracellular environment. Subsequently, a microfluidic sensing system was developed by integrating the optimised …

    adelaide Repository record for A microfluidic sensing system for simultaneous monitoring of extracellular Ca(II) and insulin secretion (opens in a new tab)

  6. Development of microfluidic systems for biological applications and their transport issues

    … polymerase chain reaction (PCR) microchip with regional velocity control is developed. Finite element analysis is conducted to study the temperature uniformity of each reaction zone. A semi-analytical heat transfer model is developed to study heat transfer inside the PCR chip. Fluid …

    texas Repository record for Development of microfluidic systems for biological applications and their transport issues (opens in a new tab)

  7. Design of quantum dot and smartphone-based luminescent bioassay platforms for prospective point-of-care diagnostics

    … combination of QDs, FRET, and a paper-in-PDMS chip enabled direct, single-step and quantitative fluorescence-based detection of thrombin activity in whole blood. The research in this thesis is a foundation for the development of novel point-of-care diagnostics assays with consumer …

    ubc Repository record for Design of quantum dot and smartphone-based luminescent bioassay platforms for prospective point-of-care diagnostics (opens in a new tab) Download PDF for Design of quantum dot and smartphone-based luminescent bioassay platforms for prospective point-of-care diagnostics (opens in a new tab)

  8. Development of a miniaturised microchip capillary electrophoresis system and analytical methods for forensic applications

    … research was to manufacture a miniaturised microchip capillary electrophoresis (MCE) system, which can be used to analyse suspected chemical agents accurately and rapidly. In order to avoid contamination during sample transportation and to provide real-time data for forensic analysis, this system …

    cork Repository record for Development of a miniaturised microchip capillary electrophoresis system and analytical methods for forensic applications (opens in a new tab)

  9. Development of an integrated microspectrometer using arrayed waveguide grating (AWG)

    … for point-of-care (POC) applications. Lab-on-a-chip technology such as microfluidics has been treated as an ideal approach to integrate complex sample processing and analysis units with optical detection elements. Spectroscopic sensing (such as fluorescence, Raman and absorption spectroscopy) …

    glasgow Download PDF for Development of an integrated microspectrometer using arrayed waveguide grating (AWG) (opens in a new tab)

  10. Nanoscale Manipulation of Electrokinetic Transport for Iontronic Applications based on Surface Modification

    … in surface-modified polydimethylsiloxane (PDMS) nanochannels, as well as applications of chip-scale nanofluidic devices with surface modifications. At the beginning of this thesis, electroosmotic flow (EOF) is measured in pristine PDMS single nanochannels by the current-slope method. This …

    waterloo Repository record for Nanoscale Manipulation of Electrokinetic Transport for Iontronic Applications based on Surface Modification (opens in a new tab)

  11. Automated microfluidic nucleic acid analysis for single-cell and sample-to-answer applications

    … into 104,000 wells of a commercial sequencing chip. The nucleic acids of the single cells are amplified inside the 18.5 pl wells and synthesized onto a surface by an immobilized primer and thus are accessible for further downstream analysis. The validation of the single-cell SP-PCR was applied …

    freiburg-diss Repository record for Automated microfluidic nucleic acid analysis for single-cell and sample-to-answer applications (opens in a new tab)

  12. BASIC AND TRANSLATIONAL ASPECTS OF CELL-BASED APPROACHES FOR EARLY AND LATE STAGE OSTEOARTHRITIS

    … and replica molding, to generate multi-well chips in polydimethylsiloxane (PDMS) for the formation and culture of cell aggregates (Chapter 6). Each PDMS chip allowed the simultaneous culture of several pellets leading to a significant reduction in the time required for pellet seeding and …